Operating Instructions MBA888
Operating Instructions MBA888
11/2017/Item No. 8001705
Page 4/6
MBA Instruments GmbH
7.
Electrical connection MBA888
7.1 With M12 plug connector
A 5-pin A code M12 coupling connector is required for electrical connection.
The cable must be a fixed installation.
Coupling connector assignment
MBA888**K*-
*00000-*-**
MBA888**
A
*-
*00000-*-**
24 V DC variant
12 V DC variant
1
Operating voltage
24 V DC ±10%
12 V DC ±10%
2
Shaft Blocked signal:
" Container full"
24 V/0 V, max. 1.2 A
12 V/0 V, max 1.2 A
3
GND
0 V
0 V
4
Shaft rotating signal:
" Container empty"
24 V/0 V, max. 1.2 A
12 V/0 V, max. 1.2 A
5
PE wire
PE wire
PE wire
7.2
With screwed cable gland and cable version
The MBA888 is supplied with a ready-to-use cable. The flexible leads at the end of the cable are numbered
1 to 5 and must be connected in a suitable terminal compartment. The housing is included in the
equipotential-bonding system. The cable must be a fixed installation.
Flexible-lead assignment 5G 0,5
MBA888**K*-
*00000-*-**
MBA888**
A
*-
*00000-*-**
24 V DC variant
12 V DC variant
1
Operating voltage
24 V DC ±10%
12 V DC ±10%
2
GND
0 V
0 V
3
Shaft Blocked signal:
"Container full"
24V /0 V, max. 1,2 A
12V /0 V, max 1,2A
4
Shaft rotating signal:
"Container empty"
24 V/0 V, max. 1.2 A
12 V/0 V, max. 1.2 A
GN/YE
PE wire
8.
Electrical connection MBA888 115 … 230 V AC
The MBA888 is supplied with a ready-to-use cable. The flexible leads at the end of the cable are
numbered 1 to 6 and must be connected in a suitable terminal compartment. The housing must
be included in the equipotential-bonding system. The cable must be a fixed installation.
Flexible-lead assignment 7G 0,75
MBA888**
L
*-*00000-*-**
115..230 V AC variant
1
Operating voltage
115 V … 230 V AC ±10%
2
N
3
Relay main contact
floating
4
Relay main contact 1
Empty indicator
5
Relay main contact 2
Full indicator
GN/YE
PE wire
6
not used
The relay switches as a changeover contact. The contacts are floating.
Output signal
Behaviour
Cause
Flexible lead
3 – 4
Flexible lead
3 – 5
Shaft rotates
Container is empty
closed
open
Shaft does not rotate Container is full
open
closed
Safety-related circuit, for use as Full indicator
If the MBA888 detects a malfunction or if the operating voltage fails, the relay drops out and displays status
"Container is full".
1 +24 V DC
2 0 V GND
3 Signal full
4 Signal empty
GN/YE
1 230 V AC
2 N
3
4
5
PE wire
6 GN/YE
4
3
5
1
2
PE
PE
PE