background image

 

TRAFx MANUAL: PART II 

 Mountain Bike Counter 

 2018 

  www.trafx.net 

G

   TESTING

 

 

Each TRAFx counter comes factory tested and ready to install.  If installed according to instructions, paying careful 
attention to the specified distances and other details, it is not normally necessary to test it.  However, if desired, there are 
several methods to test a counter.   
 

1  WITH PC 

With this method, counts immediately appear on your PC screen.  This is useful when first learning about your counter 
indoors, and also at installation locations, with a laptop.  See below.  

 

1.  Confirm dock is in PC Mode 
2.  Connect: PC---cable(s)---dock---counter 
3.  Open TRAFx Communicator and click GO! 
4. 

Enter “T” for 

TEST

 and press 

Enter (

 )

 

 

As a bike passes within the detection zone, or as you move a ferrous metal object (pliers, 
hammer, stapler 

 but not a magnet or magnetic screwdriver) near the counter (approx. 10cm 

/ 6in.), this should trigger a count which appears on 

the PC’s screen

.  Try it.  Ferrous metal 

objects (i.e., metals with iron content) distort the earth's magnetic field as they move through 
it, and this triggers a count.  Pure aluminum (non-alloy aluminum) will not be detected.  
        

                                                            

Counts appear on screen 

 

 

 
 

Moving the counter (i.e., pointing it in different compass directions, or tilting it, or jiggling or 
jolting it) will also cause counts to occur 

 try this. This is because the earth's magnetic field 

has different strengths for different directions and tilts, and the counter senses this. 
 
If you move the counter too close to a computer or other electrical equipment, counts might 
also occur.  This is because certain types of electrical equipment create changing electro-
magnetic fields, which the counter detects.  It

’s

 also sensitive to very rapid temperature 

change (e.g., direct sun).

 

  

 

5.  To end the 

TEST

, enter ZZZZ 

6.  To 

ERASE

 

the test counts from the counter’s memory,

 e

nter “E” 

                             

 

 

 

2  WITHOUT PC 

For this method, launch the counter and collect data for a few hours.  Note that counting begins at 

START

 (top of the hour) 

and that you must wait a full hour after 

START

 to download data. 

            Example: 

10:40 - Launched counter > 

S

tatus LIGHT blinks rapidly until 

START

 is reached 

11:00 - Top of the hour (

START

) > counting begins > 

D

etection LIGHT blinks upon count 

12:00 - Okay to download data now. 

                                                                                                                                  
In short, wait at least a few hours before downloading data.   
 

 

3  WATCH DETECTION

 LIGHT  

This is a variation of Method 2.  As mentioned above, counting begins at 

START

 (normally top of the hour).  After 

START

the 

counter’s 

D

etection LIGHT blinks when a count occurs (two blinks means two counts).   

 
 
                                                           watch the blinks 
 
 
.   

 

 

Содержание TRAFx Generation 2

Страница 1: ...ntained design no external wires or tubes Designed to be buried Small and easy to hide reduces vandalism risk Long battery life G4 up to 9 months Large storage capacity millions of counts Built for ou...

Страница 2: ...tery wires connect to the counter s screw block as shown below Ensure wires are fully inserted and the screws are tight Gently tug test each wire Incorrectly connected wires could cause damage and voi...

Страница 3: ...the counter to be counted Installing the counter within 0 75m 2 5ft of passing bikes is optimum Overall rule of thumb the closer the better The detection zone is spherical extending out in all directi...

Страница 4: ...6 05 28 14 19 22 31 DELAY DELAY refers to delay after event During DELAY other events triggers are ignored DELAY values and seconds are shown below DELAY Seconds A count occurs in the detection zone T...

Страница 5: ...some drainage rocks 2 Fill the bottom with 5 to 7cm 2 to 3in of rocks STEP 3 LAUNCH AND PLACE COUNTER 1 Launch the counter using your dock in Shuttle Mode Use Shuttle Mode s checklist next page 2 Add...

Страница 6: ...ate If the Replace Counter s Batteries LIGHT blinks disconnect replace the counter s batteries and then reconnect 4 After disconnecting the counter s Status LIGHT should be blinking rapidly this confi...

Страница 7: ...idely sold Costco Home Depot etc use quality alkaline batteries e g Energizer rechargeables not recommended last 40 to 70 less than alkaline batteries in extremely cold climates consistently below 20C...

Страница 8: ...ng the counter i e pointing it in different compass directions or tilting it or jiggling or jolting it will also cause counts to occur try this This is because the earth s magnetic field has different...

Страница 9: ...r s Calibration LIGHT is permanently ON i e solid a rotate the counter 180 degrees or b remove and reinsert all its batteries and Download Launch it again or c move it farther away from large metal ob...

Отзывы: