background image

 

TRAFx MANUAL: PART II 

 Mountain Bike Counter 

 2018 

  www.trafx.net 

E

   CHECKLISTS 

                                

Field Equipment Checklist 

 

 

TRAFx Manual: Part I and II 

 

Counters, dock, etc  

 

Desiccant packs (in sealed bag); spare batteries for counter; Ziploc bags 

 

Items y

ou’ll need for installation

 

 

Tape measure, camera, GPS, shovel, toothbrush, umbrella, safety equipment, etc 

 

 
 

Installation do 

and don’t

 

Do: 

 

install at proper distance (p. 3); use tape measure!

 

 

Install perpendicular to the trail (p. 5)

 

 

install where bike speed is moderate (not on downhill)

 

 

install at choke points where bikes are single file

 

 

install where bicycles pass by without stopping

 

 

place inside sealed bag, container or box (see p. 5) 

 

 

Don’t

 install: 

 

where water pools or collects

 

 

within 10m (33ft.) of a road

 

 

within 20m (65ft.) of a train line

 

 

near high-voltage powerlines (overhead or underground)

 

 

inside a steel box

 

 
 

Download, launch, etc. checklist

 

Dock in Shuttle Mode 

(recommended) 

Dock in PC Mode 

(not recommended) 

 

 

 
 

 
 

 
 
Use your dock in Shuttle Mode to Download / Launch a counter, 
without a PC.   

 

     Before going to the field confirm: 

1.

 

The dock’s 

TIME

 is correct, (yy-mm-dd and 24 hr time).   

2.

 

The dock’s battery voltage

 is 

3.4

 or higher (if not, replace 

dock’s batteries and reconfigure 

TIME

). 

3.

 

Erase old data stored in the dock’s memory.  Enter E.

 

 

     Go to a counter in the field

  

1.

 

Confirm dock is in Shuttle Mode. 

2.

 

Connect to a counter. 

3.

 

Do what the dock’s LIGHTs indicate.

   

--If the 

Replace Counter’s Batteries

 LIGHT blinks, 

disconnect, replace the counter’s batteries and then 

reconnect.   

4.

 

After disconnecting, the counter’s

 

S

tatus LIGHT should be 

blinking rapidly; this confirms a successful launch.  If not, 

repeat 2 and 3. 

5.

 

Put a fresh desiccant 

pack inside the counter’s case. 

 

  

Go to the next counter.  Repeat 1 to 5. 
 

     Back in office 

 

Open TRAFx Communicator and follow its instructions 

 

Make sure you are in Shuttle Mode 

 

Click on 

D

 to download and save Shuttle file 

 

Upload Shuttle file to your DataNet account 

 

See TRAFx Manual Part I, p. 13 to 15 for details.   

 

 
 

 
 

 
 

Using a PC to Download / Launch counters is not 
recommended because it is slower and more prone to 

human error than Shuttle Mode.  
 

However, these are the main steps: 
 

1.

 

Confirm dock is in PC Mode. 

2.

 

Open TRAFx Communicator and follow its 

instructions. 

3.

 

Click on 

D

 to download and save data. 

4

4

.

.

 

 

Find saved data file and confirm successful 
download.

 

 

 

 
To continue to collect data, you 

must relaunch the

 

cou

nter by entering “L”.  Ensure that the counter’s 

TIME

 is correct.  When prompted, erase existing data.  

Data logging will begin at the 

START

 date/time.  Also, 

don’t forget to replace the desiccant pack.

 

 

After disconnecting, the counter’s 

S

tatus LIGHT should 

be blinking rapidly; this confirms a successful launch.  

If not, connect up and launch it again. 
 

See TRAFx Manual Part I, p. 10 to 12 for details.   
 

Back in office 

 

Upload file to your DataNet account 

 
 

 

Maintenance reminder

keep the field case’s l

id seal free of dirt and organic material, with a toothbrush.  Otherwise, it might 

leak. 

 
 
 

Содержание TRAFx Generation 2

Страница 1: ...ntained design no external wires or tubes Designed to be buried Small and easy to hide reduces vandalism risk Long battery life G4 up to 9 months Large storage capacity millions of counts Built for ou...

Страница 2: ...tery wires connect to the counter s screw block as shown below Ensure wires are fully inserted and the screws are tight Gently tug test each wire Incorrectly connected wires could cause damage and voi...

Страница 3: ...the counter to be counted Installing the counter within 0 75m 2 5ft of passing bikes is optimum Overall rule of thumb the closer the better The detection zone is spherical extending out in all directi...

Страница 4: ...6 05 28 14 19 22 31 DELAY DELAY refers to delay after event During DELAY other events triggers are ignored DELAY values and seconds are shown below DELAY Seconds A count occurs in the detection zone T...

Страница 5: ...some drainage rocks 2 Fill the bottom with 5 to 7cm 2 to 3in of rocks STEP 3 LAUNCH AND PLACE COUNTER 1 Launch the counter using your dock in Shuttle Mode Use Shuttle Mode s checklist next page 2 Add...

Страница 6: ...ate If the Replace Counter s Batteries LIGHT blinks disconnect replace the counter s batteries and then reconnect 4 After disconnecting the counter s Status LIGHT should be blinking rapidly this confi...

Страница 7: ...idely sold Costco Home Depot etc use quality alkaline batteries e g Energizer rechargeables not recommended last 40 to 70 less than alkaline batteries in extremely cold climates consistently below 20C...

Страница 8: ...ng the counter i e pointing it in different compass directions or tilting it or jiggling or jolting it will also cause counts to occur try this This is because the earth s magnetic field has different...

Страница 9: ...r s Calibration LIGHT is permanently ON i e solid a rotate the counter 180 degrees or b remove and reinsert all its batteries and Download Launch it again or c move it farther away from large metal ob...