background image

 

TRAFx MANUAL: PART II 

 Mountain Bike Counter 

 2018 

  www.trafx.net 

B

   INSTALLATION OPTIONS 

 

There are two main installation options: (A) middle of the trail, or (B) at the side of the trail.   
 

 

The maximum detection range is approximately 1m (3.3ft.).  That is, all bikes must pass within 1m (3.3ft.) of 
the counter to be counted.  Installing the counter within 0.75m (2.5ft.) of passing bikes is optimum.  Overall 
rule of thumb: the closer, the better.    

 

 

The detection zone is spherical, extending out in all directions from the counter.  

 

 

Use Option A on trails that are wider than 1m (3.3ft.); use Option B for trails less than 1m (3.3ft) wide. 

 

 

 
 
 
 

 
Because the detection zone is spherical, the counter can be installed under a bridge or ramp as long as the 
distances specified above are respected.   
 

 

 
 
 
 
 
                                                 bridge                                                                     ramp 

Содержание TRAFx Generation 2

Страница 1: ...ntained design no external wires or tubes Designed to be buried Small and easy to hide reduces vandalism risk Long battery life G4 up to 9 months Large storage capacity millions of counts Built for ou...

Страница 2: ...tery wires connect to the counter s screw block as shown below Ensure wires are fully inserted and the screws are tight Gently tug test each wire Incorrectly connected wires could cause damage and voi...

Страница 3: ...the counter to be counted Installing the counter within 0 75m 2 5ft of passing bikes is optimum Overall rule of thumb the closer the better The detection zone is spherical extending out in all directi...

Страница 4: ...6 05 28 14 19 22 31 DELAY DELAY refers to delay after event During DELAY other events triggers are ignored DELAY values and seconds are shown below DELAY Seconds A count occurs in the detection zone T...

Страница 5: ...some drainage rocks 2 Fill the bottom with 5 to 7cm 2 to 3in of rocks STEP 3 LAUNCH AND PLACE COUNTER 1 Launch the counter using your dock in Shuttle Mode Use Shuttle Mode s checklist next page 2 Add...

Страница 6: ...ate If the Replace Counter s Batteries LIGHT blinks disconnect replace the counter s batteries and then reconnect 4 After disconnecting the counter s Status LIGHT should be blinking rapidly this confi...

Страница 7: ...idely sold Costco Home Depot etc use quality alkaline batteries e g Energizer rechargeables not recommended last 40 to 70 less than alkaline batteries in extremely cold climates consistently below 20C...

Страница 8: ...ng the counter i e pointing it in different compass directions or tilting it or jiggling or jolting it will also cause counts to occur try this This is because the earth s magnetic field has different...

Страница 9: ...r s Calibration LIGHT is permanently ON i e solid a rotate the counter 180 degrees or b remove and reinsert all its batteries and Download Launch it again or c move it farther away from large metal ob...

Отзывы: