background image

8

2. Firmly grasp the body of the dryer (not the top or console 

panel). Gently lay the dryer on the cardboard. 

3. Examine the leveling legs. Find the diamond marking. 

4. Screw the legs into the leg holes by hand. Use a wrench to 

finish turning the legs until the diamond marking is no longer 
visible.

5. Place a carton corner post under each of the 2 dryer back 

corners. Stand the dryer up. Slide the dryer on the corner 
posts until it is close to its final location. Leave enough room 
to connect the exhaust vent.

6. Once connection is made and dryer is in final location, remove 

corner posts and cardboard.

For mobile home use

Gas dryers must be securely fastened to the floor.

Mobile home installations require a Mobile Home Installation Kit. 
For information on ordering please reference the Dryer User 
Instructions.

Make Gas Connection

1. Remove the red cap from the gas pipe. 
2. Using a wrench to tighten, connect the gas supply to the 

dryer. Use pipe-joint compound on the threads of all non-
flared male fittings. If flexible metal tubing is used, be sure 
there are no kinks.

NOTE: For LP gas connections, you must use pipe-joint 
compound resistant to the action of LP gas. Do not use 
TEFLON

®†

 tape.

A combination of pipe fittings must be used to connect the 
dryer to the existing gas line. Shown is a recommended 
connection. Your connection may be different, according to 
the supply line type, size, and location.

3. Open the shutoff valve in the supply line. The valve is open 

when the handle is parallel to the gas pipe.

4. Test all connections by brushing on an approved noncorrosive 

leak-detection solution. Bubbles will show a leak. Correct any 
leak found.

Connect Vent

1. Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in 

dryer. If connecting to existing vent, make sure the vent is 
clean. The dryer vent must fit over the dryer exhaust outlet 
and inside the exhaust hood. Check that the vent is secured 
to exhaust hood with a 4" (10.2 cm) clamp.

2. Move dryer into its final location. Do not crush or kink vent.
3. (On gas models) Check that there are no kinks in the flexible 

gas line.

4. Once the exhaust vent connection is made, remove the corner 

posts and cardboard.

Level Dryer

Check the levelness of the dryer. Check levelness first side to 
side, then front to back.

If the dryer is not level, prop up the dryer using a wood block. Use 
a wrench to adjust the legs up or down and check again for 
levelness.

A. Flared male thread
B. Non-flared male thread

A

B

®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.

A.

³⁄₈

" flexible gas connector

B.

³⁄₈

" dryer pipe 

C.

³⁄₈

" to 

³⁄₈

" pipe elbow

D.

³⁄₈

" pipe-to-flare adapter fitting

A. Closed valve
B. Open valve

A

B

C

D

A

Содержание MGDC400VW - Centennial 29" Gas Dryer

Страница 1: ...Planification du syst me d vacuation 16 Installation du syst me d vacuation 17 Installation des pieds de nivellement 17 Raccordement au gaz 18 Raccordement du conduit d vacuation 18 Mise niveau de la...

Страница 2: ...lding Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be...

Страница 3: ...12 7 cm clearance behind the dryer for the exhaust vent with elbow See Venting Requirements Installation spacing for recessed area or closet installation The following spacing dimensions are recommend...

Страница 4: ...on IPS pipe is recommended approved aluminum or copper tubing is acceptable for lengths under 20 ft 6 1 m if local codes and gas supplier permit If you are using Natural gas do not use copper tubing L...

Страница 5: ...Observe all governing codes and ordinances The dryer exhaust must not be connected into any gas vent chimney wall ceiling or a concealed space of a building If using an existing vent system Clean lin...

Страница 6: ...ch PlanVentSystem Choose your exhaust installation type Recommended exhaust installations Typical installations vent the dryer from the rear of the dryer Other installations are possible Standard exha...

Страница 7: ...ng times and increased energy usage The Vent system chart provides venting requirements that will help to achieve the best drying performance Vent system chart NOTE Side and bottom exhaust installatio...

Страница 8: ...st be used to connect the dryer to the existing gas line Shown is a recommended connection Your connection may be different according to the supply line type size and location 3 Open the shutoff valve...

Страница 9: ...screws in cabinet are in large part of hinge slot Pull door forward off screws Set door handle side up on top of dryer Remove top screws from cabinet 4 Remove screws attaching hinges to door 5 Remove...

Страница 10: ...Temperature setting If the dryer will not start check the following Dryer is plugged into a grounded 3 prong outlet Electrical supply is connected Household fuse is intact and tight or circuit breake...

Страница 11: ...ront le symbole d alerte de s curit et le mot DANGER ou AVERTISSEMENT Ces mots signifient IMPORTANTES INSTRUCTIONS DE S CURIT CONSERVEZ CES INSTRUCTIONS Avant de jeter ou de ranger votre vieille s che...

Страница 12: ...la s cheuse n est pas d aplomb le linge peut ne pas culbuter convenablement et les programmes command s par des d tecteurs automatiques peuvent ne pas fonctionner correctement Ne pas faire fonctionne...

Страница 13: ...riqu es Titre 24 HUD partie 280 ou de la Norme canadienne des habitations pr fabriqu es CAN CSA Z240MH L installation dans une maison mobile exige Un syst me d vacuation en m tal disponible l achat ch...

Страница 14: ...t manuel individuel soit install en de de 6 pieds 1 8 m de la s cheuse et l emplacement doit tre facile atteindre pour l ouverture et la fermeture Exigences concernant le raccordement au gaz Utiliser...

Страница 15: ...vacuation pour atteindre le meilleur rendement de s chage En cas de nouveau syst me d vacuation Mat riel pour l vacuation Utiliser un conduit d vacuation en m tal lourd Ne pas utiliser un conduit de...

Страница 16: ...ypiques consistent acheminer le conduit d vacuation l arri re de la s cheuse D autres installations sont possibles Installations standard du conduit d vacuation l aide d un conduit m tallique rigide o...

Страница 17: ...des syst mes d vacuation fournit les exigences d vacuation qui vous aideront atteindre la meilleure performance de s chage Tableau des syst mes d vacuation REMARQUE Les installations d vacuation du c...

Страница 18: ...z existante On voit ci dessous une illustration d un raccordement recommand Le raccordement peut varier selon le type d alimentation la dimension et l emplacement 3 Ouvrir le robinet d arr t du condui...

Страница 19: ...che de la porte vers la gauche ou la droite dans son logement pour ajuster l alignement Porte r versible extra large pivotement lat ral 1 Placer une serviette A sur la s cheuse pour prot ger la surfa...

Страница 20: ...t sur la s cheuse 7 Jeter recycler tout le mat riel d emballage 8 Lire Utilisation de la s cheuse dans les Instructions pour l utilisateur de la s cheuse 9 Essuyer soigneusement l int rieur du tambour...

Отзывы: