background image

4

Mobile Home - Additional Installation Requirements

This dryer is suitable for mobile home installations. 
The installation must conform to the Manufactured Home 
Construction and Safety Standard, Title 24 CFR, Part 3280 
(formerly the Federal Standard for Mobile Home Construction and 
Safety, Title 24, HUD Part 280) or the Canadian Manufactured 
Home Standard, CAN/CSA-Z240 MH.
Mobile home installations require:

Metal exhaust system hardware, which is available for 
purchase from your dealer.

Mobile Home Installation Kit Part #346764. See “Tools and 
Parts” section for information on ordering.

Special provisions must be made in mobile homes to 
introduce outside air into the dryer. The opening (such as a 
nearby window) should be at least twice as large as the dryer 
exhaust opening.

Electrical Requirements

A 120 Volt, 60 Hz., AC only, 15- or 20-amp, fused electrical 
supply is required. A time-delay fuse or circuit breaker is 
recommended. It is recommended that a separate circuit 
serving only this dryer be provided.

Gas Supply Requirements

Gas Type

Natural Gas:

This dryer is equipped for use with Natural gas. It is design-
certified by CSA International for LP (propane or butane) gases 
with appropriate conversion.

Your dryer must have the correct burner for the type of gas in 
your home. Burner information is located on the rating plate in 
the door well of your dryer. If this information does not agree 
with the type of gas available, contact your dealer or call the 
phone numbers referenced on the front page of the Dryer User 
Instructions. 

LP gas conversion:

Conversion must be made by a qualified technician.

No attempt shall be made to convert the appliance from the gas 
specified on the model/serial rating plate for use with a different 
gas without consulting your gas company.

Gas Supply Line:

Must include 

¹⁄₈

NPT minimum plugged tapping accessible 

for test gauge connection, immediately upstream of the gas 
connection to the dryer. See illustration.

¹⁄₂

" IPS pipe is recommended.

³⁄₈

" approved aluminum or copper tubing is acceptable for 

lengths under 20 ft (6.1 m) if local codes and gas supplier 
permit.

If you are using Natural gas, do not use copper tubing.

Lengths over 20 ft (6.1 m) should use larger tubing and a 
different size adapter fitting.

If your dryer has been converted to use LP gas, 

³⁄₈

" LP 

compatible copper tubing can be used. If the total length of 
the supply line is more than 20 ft (6.1 m), use larger pipe. 

NOTE: Pipe-joint compounds that resist the action of LP gas 
must be used. Do not use TEFLON

®†

 tape.

Must include a shutoff valve:

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death, 
fire, or electrical shock.

WARNING

GROUNDING INSTRUCTIONS

SAVE THESE  INSTRUCTIONS

■  

For a grounded, cord-connected dryer: 

This dryer must be grounded. In the event of malfunction or 
breakdown, grounding will reduce the risk of electric shock 
by providing a path of least resistance for electric current. 
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must 
be plugged into an appropriate outlet that is properly 
installed and grounded in accordance with all local codes 
and ordinances.

WARNING: 

Improper connection of the equipment-

grounding conductor can result in a risk of electric shock. 
Check with a qualified electrician or service representative 
or personnel if you are in doubt as to whether the dryer is 
properly grounded. Do not modify the plug provided with the 
dryer: if it will not fit the outlet, have a proper outlet installed 
by a qualified electrician.

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line.

Install a shut-off valve.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure 
gas pressure does not exceed 13" (33 cm) water 
column. 

Examples of a qualified person include: 

licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.

Failure to do so can result in death, explosion, or fire.

Содержание MGDC400VW - Centennial 29" Gas Dryer

Страница 1: ...Planification du syst me d vacuation 16 Installation du syst me d vacuation 17 Installation des pieds de nivellement 17 Raccordement au gaz 18 Raccordement du conduit d vacuation 18 Mise niveau de la...

Страница 2: ...lding Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be...

Страница 3: ...12 7 cm clearance behind the dryer for the exhaust vent with elbow See Venting Requirements Installation spacing for recessed area or closet installation The following spacing dimensions are recommend...

Страница 4: ...on IPS pipe is recommended approved aluminum or copper tubing is acceptable for lengths under 20 ft 6 1 m if local codes and gas supplier permit If you are using Natural gas do not use copper tubing L...

Страница 5: ...Observe all governing codes and ordinances The dryer exhaust must not be connected into any gas vent chimney wall ceiling or a concealed space of a building If using an existing vent system Clean lin...

Страница 6: ...ch PlanVentSystem Choose your exhaust installation type Recommended exhaust installations Typical installations vent the dryer from the rear of the dryer Other installations are possible Standard exha...

Страница 7: ...ng times and increased energy usage The Vent system chart provides venting requirements that will help to achieve the best drying performance Vent system chart NOTE Side and bottom exhaust installatio...

Страница 8: ...st be used to connect the dryer to the existing gas line Shown is a recommended connection Your connection may be different according to the supply line type size and location 3 Open the shutoff valve...

Страница 9: ...screws in cabinet are in large part of hinge slot Pull door forward off screws Set door handle side up on top of dryer Remove top screws from cabinet 4 Remove screws attaching hinges to door 5 Remove...

Страница 10: ...Temperature setting If the dryer will not start check the following Dryer is plugged into a grounded 3 prong outlet Electrical supply is connected Household fuse is intact and tight or circuit breake...

Страница 11: ...ront le symbole d alerte de s curit et le mot DANGER ou AVERTISSEMENT Ces mots signifient IMPORTANTES INSTRUCTIONS DE S CURIT CONSERVEZ CES INSTRUCTIONS Avant de jeter ou de ranger votre vieille s che...

Страница 12: ...la s cheuse n est pas d aplomb le linge peut ne pas culbuter convenablement et les programmes command s par des d tecteurs automatiques peuvent ne pas fonctionner correctement Ne pas faire fonctionne...

Страница 13: ...riqu es Titre 24 HUD partie 280 ou de la Norme canadienne des habitations pr fabriqu es CAN CSA Z240MH L installation dans une maison mobile exige Un syst me d vacuation en m tal disponible l achat ch...

Страница 14: ...t manuel individuel soit install en de de 6 pieds 1 8 m de la s cheuse et l emplacement doit tre facile atteindre pour l ouverture et la fermeture Exigences concernant le raccordement au gaz Utiliser...

Страница 15: ...vacuation pour atteindre le meilleur rendement de s chage En cas de nouveau syst me d vacuation Mat riel pour l vacuation Utiliser un conduit d vacuation en m tal lourd Ne pas utiliser un conduit de...

Страница 16: ...ypiques consistent acheminer le conduit d vacuation l arri re de la s cheuse D autres installations sont possibles Installations standard du conduit d vacuation l aide d un conduit m tallique rigide o...

Страница 17: ...des syst mes d vacuation fournit les exigences d vacuation qui vous aideront atteindre la meilleure performance de s chage Tableau des syst mes d vacuation REMARQUE Les installations d vacuation du c...

Страница 18: ...z existante On voit ci dessous une illustration d un raccordement recommand Le raccordement peut varier selon le type d alimentation la dimension et l emplacement 3 Ouvrir le robinet d arr t du condui...

Страница 19: ...che de la porte vers la gauche ou la droite dans son logement pour ajuster l alignement Porte r versible extra large pivotement lat ral 1 Placer une serviette A sur la s cheuse pour prot ger la surfa...

Страница 20: ...t sur la s cheuse 7 Jeter recycler tout le mat riel d emballage 8 Lire Utilisation de la s cheuse dans les Instructions pour l utilisateur de la s cheuse 9 Essuyer soigneusement l int rieur du tambour...