In the U.S.A.:

An individual manual shutoff valve must be installed within 
six (6) feet (1.8 m) of the dryer in accordance with the National 
Fuel Gas Code, ANSI Z223.1.

In Canada:

An individual manual shutoff valve must be installed in 
accordance with the B149.1, Natural Gas and Propane 
Installation Code. It is recommended that an individual manual 
shutoff valve be installed within six (6) feet (1.8 m) 
of the dryer. 

The location should be easy to reach for opening and closing.

Gas supply connection requirements

Use an elbow and a 

³⁄₈

" flare x 

³⁄₈

" NPT adapter fitting between 

the flexible gas connector and the dryer gas pipe, as needed 
to avoid kinking.

Use only pipe-joint compound. Do not use TEFLON

®†

 tape.

This dryer must be connected to the gas supply line with a 
listed flexible gas connector that complies with the standard 
for connectors for gas appliances, ANSI Z21.24 or CSA 6.10.

Burner Input Requirements:

Elevations above 10,000 ft (3,048 m):

When installed above 10,000 ft (3,048 m) a 4% reduction of 
the burner Btu rating shown on the model/serial number plate 
is required for each 1,000 ft (305 m) increase in elevation.

Gas supply pressure testing

The dryer must be disconnected from the gas supply piping 
system during pressure testing at pressures greater than 
½ psi.

Dryer Gas Pipe

The gas pipe that comes out through the rear of your dryer 
has a 

³⁄₈

" male pipe thread.

A. 

³⁄₈

" NPT dryer pipe

Venting Requirements

WARNING: 

To reduce the risk of fire, this dryer MUST BE 

EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
The dryer exhaust must not be connected into any gas vent, 
chimney, wall, ceiling or a concealed space of a building.

If using an existing vent system

Clean lint from the entire length of the system and make sure 
exhaust hood is not plugged with lint. 

Replace any plastic or metal foil vent with rigid or flexible 
heavy metal vent.

Review Vent system chart. Modify existing vent system if 
necessary to achieve the best drying performance.

If this is a new vent system 

Vent material

Use a heavy metal vent. Do not use plastic or metal foil vent.

4" (10.2 cm) heavy metal exhaust vent and clamps must be 
used. DURASAFE™ venting products are recommended.

DURASAFE™ vent products can be purchased from your 
dealer or the toll-free number listed on the cover of the Dryer 
User Instructions. For more information, see the “Assistance 
or Service” section of the Dryer User Instructions.

Rigid metal vent

For best drying performance, rigid metal vents are 
recommended.

Rigid metal vent is recommended to avoid crushing and 
kinking.

Flexible metal vent

Flexible metal vents are acceptable only if accessible for 
cleaning.

Flexible metal vent must be fully extended and supported 
when the dryer is in its final location. 

A.

³⁄₈

" flexible gas connector

B.

³⁄₈

" pipe to flare adapter fitting

C.

¹⁄₈

" NPT minimum plugged tapping

D. ½" NPT gas supply line

E. Gas shutoff valve

A

B

E

D

C

®TEFLON  is a registered trademark of E.I. Du Pont De Nemours and Company.

A

1¼"

(3.2 cm)

9¼"

(23.5 cm)

4" (10.2 cm) heavy metal exhaust vent

WARNING

Fire Hazard

Use a heavy metal vent.

Do not use a plastic vent.

Do not use a metal foil vent.

Failure to follow these instructions can result in death 
or fire.

4"

10.2 cm

Содержание MGDC400VW - Centennial 29" Gas Dryer

Страница 1: ...Planification du syst me d vacuation 16 Installation du syst me d vacuation 17 Installation des pieds de nivellement 17 Raccordement au gaz 18 Raccordement du conduit d vacuation 18 Mise niveau de la...

Страница 2: ...lding Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be...

Страница 3: ...12 7 cm clearance behind the dryer for the exhaust vent with elbow See Venting Requirements Installation spacing for recessed area or closet installation The following spacing dimensions are recommend...

Страница 4: ...on IPS pipe is recommended approved aluminum or copper tubing is acceptable for lengths under 20 ft 6 1 m if local codes and gas supplier permit If you are using Natural gas do not use copper tubing L...

Страница 5: ...Observe all governing codes and ordinances The dryer exhaust must not be connected into any gas vent chimney wall ceiling or a concealed space of a building If using an existing vent system Clean lin...

Страница 6: ...ch PlanVentSystem Choose your exhaust installation type Recommended exhaust installations Typical installations vent the dryer from the rear of the dryer Other installations are possible Standard exha...

Страница 7: ...ng times and increased energy usage The Vent system chart provides venting requirements that will help to achieve the best drying performance Vent system chart NOTE Side and bottom exhaust installatio...

Страница 8: ...st be used to connect the dryer to the existing gas line Shown is a recommended connection Your connection may be different according to the supply line type size and location 3 Open the shutoff valve...

Страница 9: ...screws in cabinet are in large part of hinge slot Pull door forward off screws Set door handle side up on top of dryer Remove top screws from cabinet 4 Remove screws attaching hinges to door 5 Remove...

Страница 10: ...Temperature setting If the dryer will not start check the following Dryer is plugged into a grounded 3 prong outlet Electrical supply is connected Household fuse is intact and tight or circuit breake...

Страница 11: ...ront le symbole d alerte de s curit et le mot DANGER ou AVERTISSEMENT Ces mots signifient IMPORTANTES INSTRUCTIONS DE S CURIT CONSERVEZ CES INSTRUCTIONS Avant de jeter ou de ranger votre vieille s che...

Страница 12: ...la s cheuse n est pas d aplomb le linge peut ne pas culbuter convenablement et les programmes command s par des d tecteurs automatiques peuvent ne pas fonctionner correctement Ne pas faire fonctionne...

Страница 13: ...riqu es Titre 24 HUD partie 280 ou de la Norme canadienne des habitations pr fabriqu es CAN CSA Z240MH L installation dans une maison mobile exige Un syst me d vacuation en m tal disponible l achat ch...

Страница 14: ...t manuel individuel soit install en de de 6 pieds 1 8 m de la s cheuse et l emplacement doit tre facile atteindre pour l ouverture et la fermeture Exigences concernant le raccordement au gaz Utiliser...

Страница 15: ...vacuation pour atteindre le meilleur rendement de s chage En cas de nouveau syst me d vacuation Mat riel pour l vacuation Utiliser un conduit d vacuation en m tal lourd Ne pas utiliser un conduit de...

Страница 16: ...ypiques consistent acheminer le conduit d vacuation l arri re de la s cheuse D autres installations sont possibles Installations standard du conduit d vacuation l aide d un conduit m tallique rigide o...

Страница 17: ...des syst mes d vacuation fournit les exigences d vacuation qui vous aideront atteindre la meilleure performance de s chage Tableau des syst mes d vacuation REMARQUE Les installations d vacuation du c...

Страница 18: ...z existante On voit ci dessous une illustration d un raccordement recommand Le raccordement peut varier selon le type d alimentation la dimension et l emplacement 3 Ouvrir le robinet d arr t du condui...

Страница 19: ...che de la porte vers la gauche ou la droite dans son logement pour ajuster l alignement Porte r versible extra large pivotement lat ral 1 Placer une serviette A sur la s cheuse pour prot ger la surfa...

Страница 20: ...t sur la s cheuse 7 Jeter recycler tout le mat riel d emballage 8 Lire Utilisation de la s cheuse dans les Instructions pour l utilisateur de la s cheuse 9 Essuyer soigneusement l int rieur du tambour...

Отзывы: