Mobile home - Additional installation requirements: 

This dryer is suitable for mobile home installations.  

The installation must conform to the Manufactured  

Home Construction and Safety Standard, Title 24 CFR,  

Part 3280 (formerly the Federal Standard for Mobile home 

construction and Safety, Title 24, HUD Part 280) or Standard 

CAN/CSA-Z240 MH.

Mobile home installations require: 

All dryers:

 

Metal exhaust system hardware, available for purchase  

from your dealer. For further information, see “Assistance  

or Service” section in your “Use and Care Guide.”

 

Special provisions must be made in mobile homes to  

introduce outside air into dryer. Openings (such as a  

nearby window) should be at least twice as large as  

dryer exhaust opening.

For gas dryers mobile home installations:

 

Mobile Home Installation Hold-down Kit Part Number 

W10432680 is available to order. For further information,  

see “Assistance or Service” section in your “Use and  

Care Guide.”

6"/0"

(152 mm/0 mm)

14" max

(356 mm)

1"/0"

(25 mm/0 mm)

1"/1"

(25 mm)

18"/18"*

(457 mm)

3"/3"

(76 mm)

3"/3"

(76 mm)

48"

2

/48"

2

(310 cm

2

)

24"

2/

24"

2

(155 cm

2

)

*Recommended/Minimum spacing 

ELECTRICAL REQUIREMENTS -  

U.S.A. ONLY (SPÉCIFICATIONS 

ÉLECTRIQUES – ÉTATS-UNIS 

SEULEMENT)

It is your responsibility:

 

To contact a qualified electrical installer.

 

To be sure that the electrical connection is adequate and in 

conformance with the National Electrical Code, ANSI/NFPA 

70 - latest edition and all local codes and ordinances. 

 

The National Electrical Code requires a 4-wire power supply 

connection for homes built after 1996, dryer circuits involved 

in remodeling after 1996, and all mobile home installations. 

 

A copy of the above code standards can be obtained from: 

National Fire Protection Association, One Batterymarch Park, 

Quincy, MA 02269.

 

To supply the required 3- or 4-wire, single phase, 120/240 

volt, 60 Hz, AC-only electrical supply (or 3- or 4-wire, 

120/208 volt electrical supply, if specified on the serial/rating 

plate) on a separate 30-amp circuit, fused on both sides of 

the line. Connect to an individual branch circuit. Do not have 

a fuse in the neutral or grounding circuit.

 

Do not use an extension cord.

 

If codes permit and a separate ground wire is used, it is 

recommended that a qualified electrician determine that the 

ground path is adequate.

If using a power supply cord:

Use a UL Listed power supply cord kit marked for use with  

clothes dryers. The kit should contain:

 

A UL Listed 30-amp power supply cord, rated 120/240 

volt minimum, with a temperature rating of 140°F (60°C) 

minimum. The cord should be type SRD or SRDT, and  

be at least 4 ft. (1.22 m) long. The wires that connect to 

the dryer must end in ring terminals or spade terminals  

with upturned ends.

 

A UL Listed strain relief.

Electrical Connection

To properly install your dryer, you must determine the type of 

electrical connection you will be using and follow the instructions 

provided for it here.

 

This dryer is manufactured ready to install with a 3-wire 

electrical supply connection. The neutral ground conductor  

is permanently connected to the neutral conductor (white 

wire) within the dryer. If the dryer is installed with a 4-wire 

electrical supply connection, the neutral ground conductor 

must be removed from the external ground connector (green 

screw), and secured under the neutral terminal (center or 

white wire) of the terminal block. When the neutral ground 

conductor is secured under the neutral terminal (center or 

white wire) of the terminal block, the dryer cabinet is isolated 

from the neutral conductor.

 

If local codes do not permit the connection of a neutral  

ground wire to the neutral wire, see “Optional 3-wire 

connection” section.

 

A 4-wire power supply connection must be used when the 

appliance is installed in a location where grounding through  

the neutral conductor is prohibited. Grounding through the 

neutral is prohibited for (1) new branch-circuit installations,  

(2) mobile homes, (3) recreational vehicles, and (4) areas  

where local codes prohibit grounding through the neutral 

conductors.

Spacing for recessed area or closet installation

The dimensions shown are for the recommended spacing 

allowed. 

 

Additional spacing should be considered for ease of 

installation and servicing.

 

Additional clearances might be required for wall, door, and 

floor moldings.

 

Additional spacing of 1" (25 mm) on all sides of the dryer is 

recommended to reduce noise transfer.

 

For closet installation, with a door, minimum ventilation 

openings in the top and bottom of the door are required. 

Louvered doors with equivalent ventilitation openings are 

acceptable.

 

Companion appliance spacing should also be considered.

Содержание MGDB835DW4

Страница 1: ...Requirements 8 Gas Type 8 Gas Supply Line 8 Gas Supply Connection Requirements 9 Burner Input Requirements 9 Dryer Gas Pipe 9 INSTALL LEVELING LEGS 9 MAKE ELECTRICAL CONNECTION U S A ONLY 10 Electrica...

Страница 2: ...2 DRYER SAFETY...

Страница 3: ...r Clear the room building or area of all occupants IMPORTANT The gas installation must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 or...

Страница 4: ...8 203 mm or 10 254 mm adjustable wrench for gas connections Pipe joint compound resistant to propane gas Plastic putty knife INSTALLATION REQUIREMENTS Leveling legs 4 Tape measure Pliers Parts needed...

Страница 5: ...RTANT Do not operate install or store dryer where it will be exposed to water weather or at temperatures below 45 F 7 C Lower temperatures may cause dryer not to shut off at end of automatic sensor cy...

Страница 6: ...fied electrician determine that the ground path is adequate If using a power supply cord Use a UL Listed power supply cord kit marked for use with clothes dryers The kit should contain A UL Listed 30...

Страница 7: ...a grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances WARNING Improper connection of the equipm...

Страница 8: ...nd gas supplier permit If you are using Natural gas do not use copper tubing WARNING Explosion Hazard Use a new CSA International approved gas supply line Install a shut off valve Securely tighten all...

Страница 9: ...f propane gas must be used Do not use TEFLON tape Must include shut off valve In the U S A An individual manual shut off valve must be installed within six 6 ft 1 8 m of the dryer in accordance with t...

Страница 10: ...rd or a direct wire connection 2 Remove terminal block cover Remove hold down screw and terminal block cover Put power supply cord through the strain relief Be sure that the wire insulation on the pow...

Страница 11: ...minal block screw B Remove neutral ground wire E from external ground conductor screw A B A E Prepare to connect neutral ground wire and neutral wire 1 B E C Connect neutral ground wire and neutral wi...

Страница 12: ...lly reinsert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw Now go to Venting Requirements 2 Connect neutral wire Connect neutral wire white or center C of...

Страница 13: ...2 38 mm from remaining 3 wires Strip insulation back 1 25 mm Shape ends of wires into hooks 1 25 mm 5 127 mm 1 Prepare your 4 wire cable for direct connection B E C 3 Connect neutral ground wire and n...

Страница 14: ...moved if needed Strip 31 2 89 mm of outer covering from end of cable Strip insulation back 1 25 mm If using 3 wire cable with ground wire cut bare wire even with outer covering Shape wire ends into ho...

Страница 15: ...neutral wire 2 Connect neutral ground wire E and neutral wire white or center wire C of power supply cord or cable under center terminal block screw B Tighten screw Connect remaining wires 3 Connect r...

Страница 16: ...d make sure exhaust hood is not plugged with lint Replace plastic or metal foil vents with rigid metal or flexible metal vents Review Vent System Chart and if necessary modify existing vent system to...

Страница 17: ...from ground or any object that may obstruct exhaust such as flowers rocks bushes or snow Acceptable Style Optional exhaust installations PLAN VENT SYSTEM Recommended exhaust installations Typical ins...

Страница 18: ...st systems longer than those specified will Shorten life of dryer Reduce performance resulting in longer drying times and increased energy usage Vent System Chart Number of 90 elbows Type of vent Angl...

Страница 19: ...r cold inlet hose to other side of Y connector Screw on coupling by hand until it is seated on connector Using pliers tighten the couplings an additional two thirds turn NOTE Do not overtighten Damage...

Страница 20: ...evel Dryer 1 Adjust leveling legs 2 If dryer is not level prop up using a wood block Use wrench to adjust legs up or down and check again for levelness Place level here Place level here CONNECT VENT 1...

Страница 21: ...f scale through the water system in the dryer Over time the buildup of lime scale may clog different parts of the water system which will reduce product performance Excessive scale buildup may lead to...

Страница 22: ...surface with the inside of the door facing up 5 Install 2 plastic plugs A into screw holes where the hinges were removed in Step 4 Reverse the strike 1 Remove the door strike A from the dryer door ope...

Страница 23: ...Remove the 10 screws from the dryer door and set screws off to the side 3 Remove the inner door by using a plastic putty knife to separate the sides and bottom of the dryer door and trim There are 2...

Страница 24: ...right side of the door 6 Remove the door hinges and set off to the side 8 Lift door up and rotate trim pieces to the opposite side from which they were removed Then screw trim pieces back in 5 Remove...

Страница 25: ...ce with the hinges lined up with the hinge holes 11 Install 6 hinge screws and the other 4 screws 12 Install hinge covers and plugs Hinge covers will go in sideways to then rotate 90 and snap into pla...

Страница 26: ...2017 All rights reserved Tous droits r serv s W11101355A W11101358A SP 03 17...

Отзывы: