Special provisions for mobile homes:

Exhaust vent must be securely fastened to a noncombustible 

portion of mobile home and must not terminate beneath the 

mobile home. Terminate exhaust vent outside. 

Moblie Home Exhaust installation

Connect vent to exhaust hood

2.

Vent must fit over the exhaust hood. Secure vent to exhaust 

hood with 4" (102 mm) clamp. Run vent to dryer location 

using straightest path possible. Avoid 90° turns. Use clamps 

to seal all joints. Do not use duct tape, screws, or other 

fastening devices that extend into interior of vent to secure 

vent, because they can catch lint.

INSTALL VENT SYSTEM

12" min.

(305 mm)

12" min.

(305 mm)

Install exhaust hood

1.

Install exhaust hood and use caulking compound to seal 

exterior wall opening around exhaust hood.

Determine vent length and elbows needed for best 

drying performance:

 

Use following Vent System Chart to determine type of vent 

material and hood combinations acceptable to use.

NOTE:

 Do not use vent runs longer than those specified  

in Vent System Chart. Exhaust systems longer than those 

specified will:

 

Shorten life of dryer.

 

Reduce performance, resulting in longer drying times  

and increased energy usage.

Vent System Chart

Number of 

90° elbows

Type of vent

Angled  

hoods

1

4

3

2

0

Rigid metal

Rigid metal

Rigid metal

Rigid metal

Rigid metal

64 ft. (20 m)

54 ft. (16.5 m)

44 ft. (13.4 m)

35 ft. (10.7 m)

27 ft. (8.2 m)

The Vent System Chart provides venting requirements that 

will help achieve best drying performance.

NOTE:

 Bottom exhaust installations have a 90° turn inside the 

dryer. To determine maximum exhaust length, add one 90° turn 

to the charts.

Determine vent path:

 

Select route that will provide straightest and most direct  

path outdoors.

 

Plan installation to use fewest number of elbows and turns.

 

When using elbows or making turns, allow as much room  

as possible.

 

Bend vent gradually to avoid kinking.

 

Use as few 90° turns as possible.

CONNECT INLET HOSES 

 

For non-steam models, skip to “Connect Vent.”

 

 

The dryer must be connected to the cold water faucet using  

the new inlet hoses. Do not use old hoses.

Turn cold water faucet off and remove washer inlet hose.
Remove old rubber washer from inlet hose and replace  

with new rubber washer. 

Turn cold water off, remove and 

replace rubber washer

1. 

Содержание MGDB835DW4

Страница 1: ...Requirements 8 Gas Type 8 Gas Supply Line 8 Gas Supply Connection Requirements 9 Burner Input Requirements 9 Dryer Gas Pipe 9 INSTALL LEVELING LEGS 9 MAKE ELECTRICAL CONNECTION U S A ONLY 10 Electrica...

Страница 2: ...2 DRYER SAFETY...

Страница 3: ...r Clear the room building or area of all occupants IMPORTANT The gas installation must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 or...

Страница 4: ...8 203 mm or 10 254 mm adjustable wrench for gas connections Pipe joint compound resistant to propane gas Plastic putty knife INSTALLATION REQUIREMENTS Leveling legs 4 Tape measure Pliers Parts needed...

Страница 5: ...RTANT Do not operate install or store dryer where it will be exposed to water weather or at temperatures below 45 F 7 C Lower temperatures may cause dryer not to shut off at end of automatic sensor cy...

Страница 6: ...fied electrician determine that the ground path is adequate If using a power supply cord Use a UL Listed power supply cord kit marked for use with clothes dryers The kit should contain A UL Listed 30...

Страница 7: ...a grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances WARNING Improper connection of the equipm...

Страница 8: ...nd gas supplier permit If you are using Natural gas do not use copper tubing WARNING Explosion Hazard Use a new CSA International approved gas supply line Install a shut off valve Securely tighten all...

Страница 9: ...f propane gas must be used Do not use TEFLON tape Must include shut off valve In the U S A An individual manual shut off valve must be installed within six 6 ft 1 8 m of the dryer in accordance with t...

Страница 10: ...rd or a direct wire connection 2 Remove terminal block cover Remove hold down screw and terminal block cover Put power supply cord through the strain relief Be sure that the wire insulation on the pow...

Страница 11: ...minal block screw B Remove neutral ground wire E from external ground conductor screw A B A E Prepare to connect neutral ground wire and neutral wire 1 B E C Connect neutral ground wire and neutral wi...

Страница 12: ...lly reinsert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw Now go to Venting Requirements 2 Connect neutral wire Connect neutral wire white or center C of...

Страница 13: ...2 38 mm from remaining 3 wires Strip insulation back 1 25 mm Shape ends of wires into hooks 1 25 mm 5 127 mm 1 Prepare your 4 wire cable for direct connection B E C 3 Connect neutral ground wire and n...

Страница 14: ...moved if needed Strip 31 2 89 mm of outer covering from end of cable Strip insulation back 1 25 mm If using 3 wire cable with ground wire cut bare wire even with outer covering Shape wire ends into ho...

Страница 15: ...neutral wire 2 Connect neutral ground wire E and neutral wire white or center wire C of power supply cord or cable under center terminal block screw B Tighten screw Connect remaining wires 3 Connect r...

Страница 16: ...d make sure exhaust hood is not plugged with lint Replace plastic or metal foil vents with rigid metal or flexible metal vents Review Vent System Chart and if necessary modify existing vent system to...

Страница 17: ...from ground or any object that may obstruct exhaust such as flowers rocks bushes or snow Acceptable Style Optional exhaust installations PLAN VENT SYSTEM Recommended exhaust installations Typical ins...

Страница 18: ...st systems longer than those specified will Shorten life of dryer Reduce performance resulting in longer drying times and increased energy usage Vent System Chart Number of 90 elbows Type of vent Angl...

Страница 19: ...r cold inlet hose to other side of Y connector Screw on coupling by hand until it is seated on connector Using pliers tighten the couplings an additional two thirds turn NOTE Do not overtighten Damage...

Страница 20: ...evel Dryer 1 Adjust leveling legs 2 If dryer is not level prop up using a wood block Use wrench to adjust legs up or down and check again for levelness Place level here Place level here CONNECT VENT 1...

Страница 21: ...f scale through the water system in the dryer Over time the buildup of lime scale may clog different parts of the water system which will reduce product performance Excessive scale buildup may lead to...

Страница 22: ...surface with the inside of the door facing up 5 Install 2 plastic plugs A into screw holes where the hinges were removed in Step 4 Reverse the strike 1 Remove the door strike A from the dryer door ope...

Страница 23: ...Remove the 10 screws from the dryer door and set screws off to the side 3 Remove the inner door by using a plastic putty knife to separate the sides and bottom of the dryer door and trim There are 2...

Страница 24: ...right side of the door 6 Remove the door hinges and set off to the side 8 Lift door up and rotate trim pieces to the opposite side from which they were removed Then screw trim pieces back in 5 Remove...

Страница 25: ...ce with the hinges lined up with the hinge holes 11 Install 6 hinge screws and the other 4 screws 12 Install hinge covers and plugs Hinge covers will go in sideways to then rotate 90 and snap into pla...

Страница 26: ...2017 All rights reserved Tous droits r serv s W11101355A W11101358A SP 03 17...

Отзывы: