Страница 1: ...MFS 50 125 INSTALLATIONANDMAINTENANCEINSTRUCTIONS INDUSTRIALWASHER PUBDATE 03 02 EXTRACTORS 504766...

Страница 2: ...5 PUTTING THE MACHINE INTO SERVICE 23 5 MAINTENANCE 24 5 1 INTRODUCTION 24 5 2 DAILY 24 5 3 MONTHLY OR AFTER 200 WORKING HOURS 24 5 4 EVERY 3 MONTHS OR AFTER 500 WORKING HOURS 24 5 5 EVERY 6 MONTHS O...

Страница 3: ...machine with frequency inverter do not change the parameters of the inverter Doing so can cause serious injury fire machine damage etc Instructions and warnings included in this manual do not cover al...

Страница 4: ...uses any responsibilities in such cases Define dangerous areas in the laundry room and do not allow people to enter if the machine is in operation MACHINE INFORMATION This manual comprises information...

Страница 5: ...mal standard deviation of the frequency 1 Electrical system of the machine 3x380 415V N 50 60Hz applicable for el heating 1x220 240V 50 60Hz not applicable for el heating 3x220 240V 50 60Hz applicable...

Страница 6: ...y system 1 connection for manifold 1 5 6 10 connections to liquid soap supply system Soap hoppers 3 5 5 CONSUMPTION Mean water consumption depends on selected programme cca 550 dm3 145 US gal STEAM CO...

Страница 7: ...imal standard deviation of the frequency 1 Electrical system of the machine 3x380 480V 50 60Hz 3x200 240V 50 60Hz 3x380 415V 50Hz 3x380V 60Hz 3x440 480V 60Hz 3x220 240V 50Hz 3x208 240V 60Hz TOTAL INPU...

Страница 8: ...or manifold 1 5 6 10 connections to liquid soap supply system Soap hoppers 5 CONSUMPTION Mean water consumption depends on selected programme cca 900 dm 3 240 US gal STEAM CONSUMPTION depends on selec...

Страница 9: ...mal standard deviation of the frequency 1 Electrical system of the machine 3x380 480V 50 60Hz 3x200 240V 50 60Hz 3x380 415V 50Hz 3x380V 60Hz 3x440 480V 60Hz 3x220 240V 50Hz 3x208 240V 60Hz TOTAL INPUT...

Страница 10: ...for manifold 1 5 6 10 connections toliquid soap supply system Soap hoppers 5 CONSUMPTION Mean water consumption depends on selected programme cca 1195 dm3 315 US gal STEAM CONSUMPTION depends on sele...

Страница 11: ...em of the machine 3x380 480V 50 60Hz 3x200 240V 50 60Hz 3x380 415V 50Hz 3x380V 60Hz 3x440 480V 60Hz 3x220 240V 50Hz 3x208 240V 60Hz TOTAL INPUT OF THE MACHINE WITH electric heating 54 kW no heating st...

Страница 12: ...r manifold 1 5 6 10 connections to liquid soap supply system Soap hoppers 5 CONSUMPTION Mean water consumption depends on selected programme cca 1500 dm3 400 US gal STEAM CONSUMPTION depends on select...

Страница 13: ...INSTALLATION AND MAINTENANCE MANUAL PUBLICATION DATE 03 02 504 766 3 5 DIMENSIONS AND CONNECTIONS OF THE MACHINE 33 40 55 kg 80 100 125 lbs 22 kg 50 lbs 5 soaphoppers 22 kg 50 lbs 3 soaphoppers Fig 3...

Страница 14: ...50 mm 1 97 50 mm 1 97 50 mm 1 97 H 1233 mm 48 54 two motors 1437 mm 56 57 one motor 1233 mm 48 54 1617 mm 63 66 1617 mm 63 66 1617 mm 63 66 I 173 mm 6 79 J 401 mm 15 8 two motors 87 mm 3 43 one motor...

Страница 15: ...city M12 To remove the machine to its final location follow these precautions All passages and spaces the machine has to be transported through at installation should be reasonably dimensioned to meet...

Страница 16: ...END TO INSTALL THE WASHING MACHINE IN A ROOM WITH A CELLAR OR ON A FLOOR HAVING ROOMS BENEATH WARNING IN CASE OF INSTALLATION IN A ROOM WITH A CELLAR OR ON A FLOOR HAVING ROOMS BENEATH THE INSTALLATIO...

Страница 17: ...BOLT M10 x 160 mm M16 x 160 mm TIGHTENING MOMENT 49 Nm 36 lbf ft 210 Nm 155 lbf ft Tab 4 3 B Fig 4 3 A Distances between washing machines walls and between other machines and optional design of the wa...

Страница 18: ...ould be made to make the water softer Only in some cases is the use of hard water desirable such as adding softener in the linen The soap supplier can help you with making the right decisions concerni...

Страница 19: ...for connecting to the laundry steam line For dimensions of connection points see fig 3 5 The value of inlet steam pressure must correspond to the range stated in chapter 2 Technical specification Any...

Страница 20: ...OT BE SUITABLE FOR CONNECTING TO AN IT SUPPLY SYSTEM 1 Earth leakage trip 2 Laundry electrical switchboard 3 Power supply protection 4 Washing machine 5 Phase conductors 6 Protective conductor 7 Main...

Страница 21: ...termined for strong electric circuits i e motors heating elements motor contactors circuit breaker main switch etc see the inner connecting diagram list A supplied with the machine SUPPLY CABLE CONNEC...

Страница 22: ...FRONT VIEW IN COUNTERCLOCKWISE DIRECTION DURING EXTRACTION IF IT ROTATES IN OPPOSITE DIRECTION DISCONNECT TWO PHASES SWITCH THEM OVER AND CHECK AGAIN THE ROTATION DIRECTION 1 Main switch 2 Bushing 3 C...

Страница 23: ...machine water system Fig 4 4 E CHECK IF THE HOSE IS TIGHTEN BY CLAMP ANY LEAKAGE OF CHEMICALS MAY CAUSE THE PARTS CORROSION INSIDE OF THE MACHINE WARNING PLACE EXTERNAL MIXER MIXERS NEAR THE MACHINE...

Страница 24: ...into service remove the three striking colour transport braces securing the vibrating machine components during the transport One brace fig 3 11 A B pos 1 is located in the front part of the machine a...

Страница 25: ...f washing soaps 4 Soap hoppers must be cleaned at the end of each working day 5 Clean up the door gaskets to remove sediments and dirt Do not use solvents or acids to clean the rubber door gasket Do n...

Страница 26: ...to the rubber bushing 3 located into the limiter 2 which is bolted to the drum front face 1 The switch attached to the switchboard is a part of the machine skeleton which is attached to the frame and...

Страница 27: ...y is to order the original part according the Spare parts manual WARNING REPLACE THE DAMAGED BOLT WITH A ONE OF THE SAME STRENGTH VALUE MARKED ON ITS HEAD IGNORING OF THE BOLT QUALITY AND MECHANICAL S...

Страница 28: ...Bolt nut Dimension Number of pcs Tightening Moments Nm Tightening Moments lbf ft A M20 x 65 24 12 600 00 443 00 B M12 x 30 8 70 00 52 00 33 kg TYPE nut KM13 1 450 00 332 00 C M12 x 35 6 70 00 52 00 D...

Страница 29: ...ricator Fig 5 8 Lubrication places of 33 40 55 kg 80 100 125 lbs machine for bearing house placed on rear of machine FOR ALL MACHINES 22 55 kg 50 125 lbs Once in 6 months or when needed grease spring...

Страница 30: ...it on the pulley faces If all points A B C D are touching the ruler the pulleys are aligned 1 Main housing with the pulley 2 Drum 3 Drive motor 4 Ruler Fig 5 9 5 10 WATER AND STEAM FILTERS Machines a...

Страница 31: ...usted tighten up the securing bolt 1 to the groove in the casing 2 thread Fig 5 11 A Machines 22 kg 50 lbs 1 Handle bolt 2 Handle sleeve 3 Door carrier beam 4 Semicircle cuts 5 Handle pin 6 Hinge bolt...

Страница 32: ...e has overload motor current protection by overcurrent relay All current protections have been set to the value according to a machine type stated on the power electrical scheme delivered with machine...

Страница 33: ...TRIPS If the laundry is equipped with the earth leakage trip in the inlet circuit of the electric switchboard it is necessary to test it regularly The earth leakage trip is a very sensitive device an...

Страница 34: ...uation occurs when microprocessor version at the end of a programme or when pressing the Stop button and the following function described in the Programming manual Electronic programmer card version W...

Страница 35: ...e inlet valve change the valve Water escaping check the inlet pipeline hoses valves filters tapes clamps their connections and eliminate possible leakage 6 3 TOO LONG HEATING TIME Electrical heating e...

Страница 36: ...ed drainage valve clean the drainage valve or exchange it Too small waste sump dimensions check the waste sump diameters and enlarge it accordingly 6 5 PROGRAMMER PROBLEMS See the chapter Troubleshoot...

Страница 37: ...witch 83 161 3 modification 1 F02 117 002 224 Microswitch 83 161 3 modification 2 PRI 401 020 021 Fuse 1 6 A 345 805 363 032 Fuse 2 5 A 345 805 163 032 Fuse 1A F02 117 001 814 Coil modification F02 10...

Страница 38: ...163 032 Fuse 1A 100 521 Grey keyboard MCB FC 100 629 Black keyboard MCB FC PRI 340 015 019 Thermostat sensor 22 kg 50 lbs 100 052 Black keyboard MCB EC PRI 348 000 123 Grey keyboard MCB EC 503 839 Th...

Страница 39: ...the machine will never be used again dismantle carefully the door with the hinge chapter 5 12 BE CAREFUL FALLING DOOR AND GLASS CAN CAUSE INJURIES 8 2 MACHINE LIQUIDATION For the machine liquidation a...

Страница 40: ...CARD PROGRAMMER K24 INSTALLATION DATE INSTALLATION CARRIED OUT BY SERIAL NUMBER ELECTRICAL DETAILS VOLT PHASE HZ NOTE ANY CONTACTS WITH YOUR DEALER REGARDING MACHINE SAFETY OR SPARE PARTS MUST INCLUD...