A – 2
16026784
© 2005 Maytag Services
Installation Instructions
fkpq^ii^qflk ao^tfkdp
cfdrob N
klqbW
c ~ ~ ~~ K
“A” = 30 inches (76.2 cm) minimum clearance between the
top of the cooking surface and the bottom of an unprotected
wood or metal cabinet, or “A” = 24 inches (61 cm) minimum
when bottom of wood or metal cabinet is protected by not
less than 1/4-inch (6.4 mm) thick flame-retardant millboard
covered with not less than No. 28 MSG sheet steel,
0.015-inch (0.381 mm) thick stainless steel, 0.024-inch
(0.610 mm) thick aluminum, or 0.020-inch (0.508 mm) thick
copper.
To eliminate the risk of burns or fire by reaching over
heated surface units, cabinet storage space located above
the surface units should be avoided. If cabinet storage is to
be provided, the risk can be reduced by installing a range
hood that projects horizontally a minimum of 5 inches (13
cm) beyond the bottom of the cabinets.
cfdrob N
1, 2, 3 - COMBUSTIBLE BUILDING WALLS.
4 - COMBUSTIBLE WALL CABINET.
A free-standing range may be installed adjacent to (0
²
from) combustible walls 1, 2 & 3.
klqbW clo fkpq^ii^qflk fk `^k^a^I ^
cobbJpq^kafkd o^kdb fp klq ql _b fkpq^iiba
`ilpbo qe^k NOjj colj ^kv ^ag^`bkq
proc^`bK
4
3
2
1
“A”
fjmloq^kq
mib^pb hbbm clo qeb rpb lc qeb
il`^i bib`qof`^i fkpmb`qloK