EXHAUST REQUIREMENTS

Exhaust duct work 

should be

  designed and installed by a qualified professional. Improperly sized duct work will

create excessive back pressure which results in slow drying, increased use of energy, and shutdown of the burner by the
airflow (sail) switch, burner hi-limit chamber hi-heat protector thermostat.

Where possible, it is suggested to provide a separate (single) exhaust duct for each dryer.

 CAUTION: IMPROPERLY SIZED OR INSTALLED EXHAUST DUCT WORK CAN

CREATE  A POTENTIAL FIRE HAZARD.

 CAUTION:

DRYER 

MUST BE

 EXHAUSTED TO THE OUTDOORS.

The exhaust duct work 

should be

 laid out in such a way that the work travels as directly as possible to the outdoors with

as few turns as possible. The shape of the duct work is not critical so long as the minimum cross section area is
provided. Single or independent dryer venting is recommended.

It is suggested that the use of 90

°

 turns be avoided; use 30

°

 or 45

°

 angles instead.

The duct work 

should be

 smooth inside with no projections from sheet metal screws or other obstructions which will

collect lint. When adding ducts, the ducts to be added should overlap the duct which it is connected. 

ALL

 duct work

joints 

must be

  taped to prevent moisture and lint from escaping into the building. Additionally, inspection doors

should be

 installed at strategic points in the exhaust duct work for periodic inspection and cleaning.

 

IMPORTANT

:

  When connecting duct work to the dryer exhaust duct, be sure that when screws are

    used they do not restrict the operation (both opening and closing) of the damper.

 NOTE:

  When the exhaust duct passes through a wall, ceiling, or roof made of combustible materials,

    the opening must be 2-inches larger (all the way around) than the duct. The duct 

must be

    centered within this opening.

To protect the outside end of horizontal duct work from the weather, a 90

°

 elbow bent downward 

should be

 installed

where the exhaust exits the building. If the duct work travels vertically up though the roof, it 

should be

 protected from

the weather by using a 180

°

 turn to point the opening downward. In either case, allow at least twice the diameter of the

duct between the duct opening and the nearest obstruction (i.e., roof of ground level).

 

IMPORTANT

:

  

DO NOT

 use screens or caps on the outside of opening of exhaust duct work.

 

IMPORTANT

:

  Exhaust back pressure measured by a manometer at the dryer exhaust are 

must not

    exceed 0.3 inches of water column (W.C.)

COMMERCIAL MULTI LOAD DRYERS - MDG30, MC2, PC2, PNA, and MNA

Содержание MDG30PCCWW

Страница 1: ...lbs 250 Kg Uncrated 500 lbs 227 Kg Gas Inlet 1 2 I D ELECTRICAL REQUIREMENTS 120 volts 60 Hz single phase some 240 volts 50 Hz models available for export Individual branch circuit serving only the dr...

Страница 2: ...ich it is connected ALL duct work joints must be taped to prevent moisture and lint from escaping into the building Additionally inspection doors should be installed at strategic points in the exhaust...

Страница 3: ...single 8 inch venting is used the duct work to the outlet cannot exceed 30 feet refer to Illus A below This calculation of 30 feet compensates or allows for the use of a maximum of only one 1 elbow RE...

Страница 4: ...ard outside outlet Illus B VERTICAL SINGLE DRYER VENTING NOTE A OPENING MUST BE TWO 2 INCHES LARGER THAN THE DUCT ALL THE WAY AROUND THE DUCT MUST BE CENTERED WITHIN THIS OPENING If the length of the...

Страница 5: ...cted to one 1 main common duct run The main common duct may be any shapes so long as the minimum cross section area is provided The main duct should be tapered with the diameter in creasing before eac...

Страница 6: ...mum of three 3 elbows including the two 2 elbows creating the 180 turned down ward outside outlet protection IMPORTANT No more than four 4 dryers maximum should be connected to one 1 main common duct...

Страница 7: ...he duct work for periodic inspection and cleaning 9 Where ever the duct passes through combustible materials the opening must be 2 inches larger all the way around than the duct The duct must be cente...

Страница 8: ...air openings are acceptable IMPORTANT Makeup air must be provided from a source free of contaminating fumes such as dry cleaning fumes Make up air contaminated by dry cleaning solvent fumes will resu...

Отзывы: