background image

6-1

07/02

Commercial
Multi-Load
Dryers

Models
MDG30MC2
MDG30PC2
MDG30PNA
MDG30MNA

PRODUCT SPECIFICATIONS

• Drive motor: 1/2 H.P. (.373 Kw)

• Air flow: 600 cubic feet (17 cubic meters) per minute.

• Amperage Draw: 9.8 amps (approximate).

• Heat source: 90,000 BTU/Hr. (22,680 kcal/hr.).

• Flush to side wall installation possible, 24" rear clearance suggested for ease of maintenance.

• Tumbler Capacity: 12.3 cu. ft. (.348 cu.m.)

• Tumbler Diameter: 30" (76.2 cm)

• Tumbler Depth: 30" (76.2 cm)

• Door Opening: 21 1/2" Dia. (54.61 cm)

• Weight: Crated: 550 lbs. (250 Kg)

    Uncrated: 500 lbs. (227 Kg)

• Gas Inlet 1/2" I.D.

ELECTRICAL REQUIREMENTS

• 120 volts, 60 Hz single phase, (some 240 volts, 50 Hz models available for export).

• Individual branch circuit serving only the dryer is recommended.

• Minimum wire size required, awg. 12 with a 20 amp fuse or comparable circuit breaker. Copper

wire only.

• Dryer must be installed and grounded in accordance with National Electrical Codes and local

codes and ordinances.

PRODUCT DIMENSIONS

COMMERCIAL MULTI LOAD DRYERS - MDG30, MC2, PC2, PNA, and MNA

6"

15.2 cm

11 1/2"

29.2 cm

8"

20.3 cm

EXHAUST

DIAMETER

6"

15.2 cm

20 1/4"

51.4 cm

62 1/2"

158.8 cm

63"

160 cm

72"

182.9 cm

GAS INLET

ELECTRICAL CONN.

REAR VIEW

TOP VIEW

43"

109.2 CM

31 3/8"

79.7 cm

Содержание MDG30PCCWW

Страница 1: ...lbs 250 Kg Uncrated 500 lbs 227 Kg Gas Inlet 1 2 I D ELECTRICAL REQUIREMENTS 120 volts 60 Hz single phase some 240 volts 50 Hz models available for export Individual branch circuit serving only the dr...

Страница 2: ...ich it is connected ALL duct work joints must be taped to prevent moisture and lint from escaping into the building Additionally inspection doors should be installed at strategic points in the exhaust...

Страница 3: ...single 8 inch venting is used the duct work to the outlet cannot exceed 30 feet refer to Illus A below This calculation of 30 feet compensates or allows for the use of a maximum of only one 1 elbow RE...

Страница 4: ...ard outside outlet Illus B VERTICAL SINGLE DRYER VENTING NOTE A OPENING MUST BE TWO 2 INCHES LARGER THAN THE DUCT ALL THE WAY AROUND THE DUCT MUST BE CENTERED WITHIN THIS OPENING If the length of the...

Страница 5: ...cted to one 1 main common duct run The main common duct may be any shapes so long as the minimum cross section area is provided The main duct should be tapered with the diameter in creasing before eac...

Страница 6: ...mum of three 3 elbows including the two 2 elbows creating the 180 turned down ward outside outlet protection IMPORTANT No more than four 4 dryers maximum should be connected to one 1 main common duct...

Страница 7: ...he duct work for periodic inspection and cleaning 9 Where ever the duct passes through combustible materials the opening must be 2 inches larger all the way around than the duct The duct must be cente...

Страница 8: ...air openings are acceptable IMPORTANT Makeup air must be provided from a source free of contaminating fumes such as dry cleaning fumes Make up air contaminated by dry cleaning solvent fumes will resu...

Отзывы: