4. 

Gas supply pipe must be located within the shaded area as 

shown in the “Cabinet Dimensions” illustration in the 

“Location Requirements” section.

Complete connection

1. 

Open the manual shut-off valve in the gas supply line. The 

valve is open when the handle is parallel to the gas pipe.

2. 

Test all connections by brushing on an approved 

noncorrosive leak-detection solution. If bubbles appear, a 

leak is indicated. Correct any leak found.

3. 

Remove cooktop burner caps and grates from parts 

package. Align recess in burner caps with pins in burner 

base. Burner caps should be level when properly positioned. 

If burner caps are not properly positioned, surface burners 

will not light. Place burner grates over burners and caps.

4. 

Plug into a grounded 3 prong outlet. 

Verify Anti-Tip Bracket Is Installed and 

Engaged

1. 

Place the outside of your foot against the bottom front of 

the oven door to keep the range from moving, and grasp the 

lower right or left side of the control panel as shown.

NOTE:

 If your countertop is mounted with a backsplash, it 

may be necessary to grasp the range higher than is shown in 

the illustration.

2. 

Slowly attempt to tilt the range forward.
If you encounter immediate resistance, the range foot is 

engaged in the anti-tip bracket.

3. 

If the rear of the range lifts more than 

1

/

2

" (1.3 cm) off the 

floor without resistance, stop tilting the range and lower it 

gently back to the floor. The range foot is not engaged in the 

anti-tip bracket.

IMPORTANT:

 If there is a snapping or popping sound when 

lifting the range, the range may not be fully engaged in the 

bracket. Check to see if there are obstructions keeping the range 

from sliding to the wall or keeping the range foot from sliding 

into the bracket. Verify that the bracket is held securely in place 

by the mounting screws.

4. 

Slide the range forward and verify that the anti-tip bracket is 

securely attached to the floor or wall.

5. 

Slide range back so the rear range foot is inserted into the 

slot of the anti-tip bracket.

IMPORTANT:

 If the back of the range is more than 2" (5.1 cm) 

from the mounting wall, the rear range foot may not engage 

the bracket. Slide the range forward and determine if there 

is an obstruction between the range and the mounting wall. 

If you need assistance or service, refer to the “Assistance or 

Service” section of the Use and Care Guide, or the cover or 

the “Warranty” section of the User Instructions, for contact 

information.

6. 

Repeat steps 1 and 2 to ensure that the range foot is 

engaged in the anti-tip bracket.
If the rear of the range lifts more than 

1

/

2

" (1.3 cm) off 

the floor without resistance, the anti-tip bracket may not 

be installed correctly. Do not operate the range without 

anti-tip bracket installed and engaged. Please reference 

the “Assistance or Service” section of the Use and Care 

Guide, or the cover or the “Warranty” section of the User 

Instructions, to contact service.

Adaptor

A

B

C

D

A.  Gas pressure regulator
B. Adapter
C.  Flexible connector
D.  Manual shut-off valve

A

A.  Closed valve
B.  Open valve

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, 
fire, or electrical shock.

WARNING

Содержание KFGD500EBL04

Страница 1: ...en gaz 23 INSTRUCTIONS D INSTALLATION 24 D ballage de la cuisini re 24 R glage des pieds de nivellement 24 Installation de la bride antibasculement 25 Raccordement au gaz 25 V rifier que la bride ant...

Страница 2: ...approved by UL or CSA For more information contact your gas supplier If a gas leak is detected follow the What to do if you smell gas instructions WARNING If the information in this manual is not foll...

Страница 3: ...r It is the installer s responsibility to comply with installation clearances specified on the model serial rating number plate The model serial rating number plate is located behind the control panel...

Страница 4: ...le 24 CFR Part 3280 formerly the Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 280 When such standard is not applicable use the Standard for Manufactured Home Installation...

Страница 5: ...round wire is used it is recommended that a qualified electrical installer determine that the ground path is adequate A copy of the above code standards can be obtained from National Fire Protection A...

Страница 6: ...es permit a new CSA design certified 4 to 5 ft 122 to 152 4 cm long 1 2 1 3 cm or 3 4 1 9 cm I D inside diameter flexible metal appliance connector may be used for connecting range to the gas supply l...

Страница 7: ...hardboard Adjust Leveling Legs 1 If range height adjustment is necessary use a wrench or pliers to loosen the 4 leveling legs This may be done with the range on its back or with the range supported on...

Страница 8: ...and an adjustable wrench to attach the flexible connector to the adapters IMPORTANT All connections must be wrench tightened Do not make connections to the gas pressure regulator too tight Making the...

Страница 9: ...the range the range may not be fully engaged in the bracket Check to see if there are obstructions keeping the range from sliding to the wall or keeping the range foot from sliding into the bracket V...

Страница 10: ...t Flame Height Adjust the height of top burner flames The cooktop LO burner flame should be a steady blue flame approximately 1 4 0 64 cm high To adjust standard burners The flame can be adjusted usin...

Страница 11: ...have all of your tools 3 Dispose of recycle all packaging materials 4 Check that the range is level See the Level Range section 5 Use a mild solution of liquid household cleaner and warm water to rem...

Страница 12: ...gas pressure does not exceed 14 36 cm water column Examples of a qualified person include licensed heating personnel authorized gas company personnel and authorized service personnel Failure to do so...

Страница 13: ...r section in the Use and Care Guide for oven door removal instructions 3 Push the bake burner cover to the right 4 Lift up and remove oven bake burner cover 5 Unscrew wing nut and remove oven baffle 6...

Страница 14: ...1 Remove broil burner screw and set aside 2 Remove the broil burner from the broil burner orifice hood The broil burner will hang in the back of the oven while changing the orifice hood 3 Turn the Num...

Страница 15: ...l gas orifice spuds in plastic parts bag for future use and keep with literature package 10 Replace burner grates 11 Complete installation See the Make Gas Connection and Electronic Ignition System se...

Страница 16: ...1 Remove oven racks from inside the oven cavity 2 Remove oven door See the Oven Door section in the Use and Care Guide for oven door removal instructions 3 Push the bake burner cover to the right 4 L...

Страница 17: ...gas orifice spud in the upper oven and replace with a Number 0 055 Natural gas orifice spud 14 Reverse steps to reinstall the orifice covers oven bake burners oven baffles and oven bake covers in both...

Страница 18: ...location Natural Gas Orifice Spud Chart Burner Rating Color Number 5 000 BTU Green 107N 7 300 BTU Yellow 125N 9 200 BTU Orange 142N 10 000 BTU Clear 149N 15 000 BTU White 180N 16 000 BTU Black 195N 5...

Страница 19: ...W10694069C 2016 Used under license in Canada All rights reserved Utilis sous licence au Canada Tous droits r serv s 9 16...

Отзывы: