Maytag KFGD500EBL04 Скачать руководство пользователя страница 7

7

Burner Input Requirements

Input ratings shown on the model/serial/rating plate are for 

elevations up to 2,000 ft (609.6 m).
For elevations above 2,000 ft (609.6 m), ratings are reduced at 

a rate of 4% for each 1,000 ft (304.8 m) above sea level (not 

applicable for Canada).

Gas Supply Pressure Testing

Gas supply pressure for testing regulator must be at least 

1" water column pressure above the manifold pressure shown 

on the model/serial/rating plate.

Line pressure testing above 

1

/

2

 psi gauge (14" WCP)

The range and its individual shut-off valve must be disconnected 

from the gas supply piping system during any pressure testing of 

that system at test pressures in excess of 

1

/

2

 psi (3.5 kPa).

Line pressure testing at 

1

/

2

 psi gauge (14" WCP) or lower

The range must be isolated from the gas supply piping 

system by closing its individual manual shut-off valve during 

any pressure testing of the gas supply piping system at test 

pressures equal to or less than 

1

/

2

 psi (3.5 kPa).

INSTALLATION INSTRUCTIONS

Unpack Range

1. 

Remove shipping materials, tape, and film from the range. 

Keep cardboard bottom under range.

2. 

Remove oven racks and parts package from inside oven.

3. 

To place range on its back, take 4 cardboard corners from 

the carton. Stack one cardboard corner on top of another. 

Repeat with the other 2 corners. Place them lengthwise on 

the floor behind the range to support the range when it is laid 

on its back.

4. 

Using 2 or more people, firmly grasp the range and gently lay 

it on its back on the cardboard corners.

5. 

Pull cardboard bottom firmly to remove.

6. 

Use an adjustable wrench to loosen the leveling legs.

7. 

Place cardboard or hardboard in front of range. Using 2 

or more people, stand range back up onto cardboard or 

hardboard.

Adjust Leveling Legs

1. 

If range height adjustment is necessary, use a wrench or 

pliers to loosen the 4 leveling legs.
This may be done with the range on its back or with the 

range supported on 2 legs after the range has been placed 

back to a standing position.

NOTE:

 To place range back up into a standing position, put 

a sheet of cardboard or hardboard in front of range. Using 2 

or more people, stand range back up onto the cardboard or 

hardboard.

2. 

Adjust the leveling legs to the correct height. Leveling legs 

can be loosened to add up to a maximum of 1" (2.5 cm). A 

minimum of 

3

/

16

" (5.0 mm) is needed to engage the anti-tip 

bracket.

NOTE:

 If height adjustment is made when range is standing, 

tilt the range back to adjust the front legs, then tilt forward to 

adjust the rear legs.

3. 

When the range is at the correct height, check that there is 

adequate clearance under the range for the anti-tip bracket. 

Before sliding range into its final location, check that the 

anti-tip bracket will slide under the range and onto the rear 

leveling leg prior to anti-tip bracket installation.

Install Anti-Tip Bracket

1. 

Remove the anti-tip bracket that is taped inside the upper 

oven with the package containing literature.

2. 

Determine which mounting method to use: floor or wall. 
If you have a stone or masonry floor, you can use the wall 

mounting method.

WARNING

Excessive Weight Hazard

Use two or more people to move and install range.
Failure to do so can result in back or other injury.

WARNING

Tip Over Hazard

A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation 

instructions.
Slide range back so rear range foot is engaged in the 

slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without anti-tip bracket installed 

and engaged.
Failure to follow these instructions can result in death 

or serious burns to children and adults.

Содержание KFGD500EBL04

Страница 1: ...en gaz 23 INSTRUCTIONS D INSTALLATION 24 D ballage de la cuisini re 24 R glage des pieds de nivellement 24 Installation de la bride antibasculement 25 Raccordement au gaz 25 V rifier que la bride ant...

Страница 2: ...approved by UL or CSA For more information contact your gas supplier If a gas leak is detected follow the What to do if you smell gas instructions WARNING If the information in this manual is not foll...

Страница 3: ...r It is the installer s responsibility to comply with installation clearances specified on the model serial rating number plate The model serial rating number plate is located behind the control panel...

Страница 4: ...le 24 CFR Part 3280 formerly the Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 280 When such standard is not applicable use the Standard for Manufactured Home Installation...

Страница 5: ...round wire is used it is recommended that a qualified electrical installer determine that the ground path is adequate A copy of the above code standards can be obtained from National Fire Protection A...

Страница 6: ...es permit a new CSA design certified 4 to 5 ft 122 to 152 4 cm long 1 2 1 3 cm or 3 4 1 9 cm I D inside diameter flexible metal appliance connector may be used for connecting range to the gas supply l...

Страница 7: ...hardboard Adjust Leveling Legs 1 If range height adjustment is necessary use a wrench or pliers to loosen the 4 leveling legs This may be done with the range on its back or with the range supported on...

Страница 8: ...and an adjustable wrench to attach the flexible connector to the adapters IMPORTANT All connections must be wrench tightened Do not make connections to the gas pressure regulator too tight Making the...

Страница 9: ...the range the range may not be fully engaged in the bracket Check to see if there are obstructions keeping the range from sliding to the wall or keeping the range foot from sliding into the bracket V...

Страница 10: ...t Flame Height Adjust the height of top burner flames The cooktop LO burner flame should be a steady blue flame approximately 1 4 0 64 cm high To adjust standard burners The flame can be adjusted usin...

Страница 11: ...have all of your tools 3 Dispose of recycle all packaging materials 4 Check that the range is level See the Level Range section 5 Use a mild solution of liquid household cleaner and warm water to rem...

Страница 12: ...gas pressure does not exceed 14 36 cm water column Examples of a qualified person include licensed heating personnel authorized gas company personnel and authorized service personnel Failure to do so...

Страница 13: ...r section in the Use and Care Guide for oven door removal instructions 3 Push the bake burner cover to the right 4 Lift up and remove oven bake burner cover 5 Unscrew wing nut and remove oven baffle 6...

Страница 14: ...1 Remove broil burner screw and set aside 2 Remove the broil burner from the broil burner orifice hood The broil burner will hang in the back of the oven while changing the orifice hood 3 Turn the Num...

Страница 15: ...l gas orifice spuds in plastic parts bag for future use and keep with literature package 10 Replace burner grates 11 Complete installation See the Make Gas Connection and Electronic Ignition System se...

Страница 16: ...1 Remove oven racks from inside the oven cavity 2 Remove oven door See the Oven Door section in the Use and Care Guide for oven door removal instructions 3 Push the bake burner cover to the right 4 L...

Страница 17: ...gas orifice spud in the upper oven and replace with a Number 0 055 Natural gas orifice spud 14 Reverse steps to reinstall the orifice covers oven bake burners oven baffles and oven bake covers in both...

Страница 18: ...location Natural Gas Orifice Spud Chart Burner Rating Color Number 5 000 BTU Green 107N 7 300 BTU Yellow 125N 9 200 BTU Orange 142N 10 000 BTU Clear 149N 15 000 BTU White 180N 16 000 BTU Black 195N 5...

Страница 19: ...W10694069C 2016 Used under license in Canada All rights reserved Utilis sous licence au Canada Tous droits r serv s 9 16...