![Maytag KFGD500EBL04 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/maytag/kfgd500ebl04/kfgd500ebl04_installation-instructions-manual_1749712012.webp)
12
GAS CONVERSIONS
Gas conversions from Natural gas to LP gas or from LP gas to
Natural gas must be done by a qualified installer.
LP Gas Conversion
1.
Turn manual shut-off valve to the closed position.
2.
Unplug range or disconnect power.
To Convert Gas Pressure Regulator
1.
Locate gas pressure regulator at the rear of the range.
IMPORTANT:
Do not remove the gas pressure regulator.
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation
instructions.
Slide range back so rear range foot is engaged in the
slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without anti-tip bracket installed
and engaged.
Failure to follow these instructions can result in death
or serious burns to children and adults.
A
B
C
A. To range
B. Shut-off valve (closed position)
C. Gas supply line
A
A. Gas pressure regulator