©2005 Maytag Services
16026549
C – 3
Gas Conversion Instructions
-8-
Orifice Conversion
1.
FROM NATURAL GAS TO LP/PROPANE GAS:
a.
Change the appliance pressure regulator from
natural to LP setting. (See figure 6, 7 or 8).
b.
Screw the burner orifice hoods down tight against
the pins. (See figure 9B). Use care to not over
tighten. Over tightening can damage the coaxial
pin inside the orifice hood.
NOTE:
On units using Eaton Oven Safety Valve,
screw the valve orifice hood down tight against
the valve body. (See figure 9D). It is important
that the hood be turned down as far as it can go
to insure that complete conversion has occurred.
c.
Adjust burner air shutter to the widest opening
that will not cause the flame to lift or blow off the
burner when cold.
NOTE:
Correctly adjusted sealed burners, can
have flames that will lift or blow without a pot over
the burner. These should be adjusted with a pot in
place.
2.
FROM LP/PROPANE GAS TO NATURAL GAS:
a.
Change the appliance pressure regulator from LP
to natural setting. (See figure 6, 7 or 8).
b.
Screw the burner orifice hoods away from the
pins. (See figure 9A). Approximately 1 1/2 to 2
turns.
NOTE:
On units using Eaton Oven Safety Valve,
screw the burner orifice hoods away from pin (see
figure 9C). Approximately 1 1/2 to 2 turns.
c.
Adjust burner air shutter to the widest opening
that will not cause the flame to lift or blow off the
burner when cold.
NOTE:
Correctly adjusted sealed burners, the
flame will lift or blow without a pot over the burner.
These should be adjusted with a pot in place.
SERVICE - PARTS INFORMATION
WHEN YOUR RANGE REQUIRES SERVICE OR
REPLACEMENT PARTS, CONTACT YOUR DEALER OR
AUTHORIZED SERVICE AGENCY. PLEASE GIVE THE
COMPLETE MODEL AND SERIAL NUMBERS OF THE
RANGE WHICH IS LOCATED ON THE RANGE MODEL
NUMBER PLATE.
FIGURE 9A
NATURAL GAS
SETTING
FIGURE 9B
LP GAS
SETTING
FOR ALL TOP BURNER AND
OVEN SAFETY VALVE CONVERSION
(EXCEPT EATON VALVE)
FOR EATON
OVEN SAFETY VALVE CONVERSION
FIGURE 9C
NATURAL GAS
SETTING
FIGURE 9D
LP GAS
SETTING
Содержание CWG3100AA Series
Страница 19: ...2005 Maytag Services 16026549 A 1 Appendix A...
Страница 25: ...2005 Maytag Services 16026549 B 1 Appendix B...
Страница 26: ...B 2 16026549 2005 Maytag Services Use and Care Information...
Страница 27: ...2005 Maytag Services 16026549 B 3 Use and Care Information...
Страница 28: ...B 4 16026549 2005 Maytag Services Use and Care Information...
Страница 29: ...2005 Maytag Services 16026549 B 5 Use and Care Information...
Страница 30: ...B 6 16026549 2005 Maytag Services Use and Care Information...
Страница 31: ...2005 Maytag Services 16026549 B 7 Care and Cleaning...
Страница 32: ...B 8 16026549 2005 Maytag Services Care and Cleaning...
Страница 33: ...2005 Maytag Services 16026549 C 1 Appendix C...