37
note: f
or
two
stage
non
-
coMMunIcatIng
outDoor
unIts
,
sYsteM
wIll
stage
aIrflow
autoMatIcallY
for
low
stage
oPeratIon
.
Tonnage
Selection
Airflow
Tonnage
Selection
Airflow
Tonnage
Selection
Airflow
Tonnage
Selection
Airflow
1
400
2.3
920
3.6
1440
4.9
1960
1.1
440
2.4
960
3.7
1480
5
2000
1.2
480
2.5
1000
3.8
1520
5.1
2040
1.3
520
2.6
1040
3.9
1560
5.2
2080
1.4
560
2.7
1080
4
1600
5.3
2120
1.5
600
2.8
1120
4.1
1640
5.4
2160
1.6
640
2.9
1160
4.2
1680
5.5
2200
1.7
680
3
1200
4.3
1720
5.6
2240
1.8
720
3.1
1240
4.4
1760
5.7
2280
1.9
760
3.2
1280
4.5
1800
5.8
2320
2
800
3.3
1320
4.6
1840
5.9
2360
2.1
840
3.4
1360
4.7
1880
6
2400
2.2
880
3.5
1400
4.8
1920
note:
tHe
sYsteM
wIll
not
ProVIDe
aIrflows
aBoVe
tHe
M
ax
a
Irflow
V
alue
.
•
3 Ton Models = 1,400 CFM
•
4 Ton Models = 1,760 CFM
•
5 Ton Models = 2,200 CFM
5.
Use the
CoolCloud
HVAC phone application to
configure/test
furnace
operations.
note: t
He
PHone
aPPlIcatIon
cannot
test
a
non
-
coMMunIcatIng
outDoor
unIt
.t
He
tHerMostat
wIll
Be
requIreD
for
outDoor
unIt
testIng
.
c
HargIng
a.
Two-stage outdoor units:
a.Provide a second stage cooling call from the
thermostat and charge accordingly.
b.
Single-stage outdoor units:
a.Provide a cooling call from the thermostat and
charge accordingly.
g
as
f
urnace
t
estIng
a. Two stage operation using the
CoolCloud
HVAC application:
a. Select the gas heat icon after entering the
furnace menus.
b. Select any value less than 50% for low stage
operation and any value greater than 50% for
high stage operation.
6.
Confirm thermostat heating and cooling calls
function properly with equipment.
q
uIck
s
tart
g
uIDe
for
g
as
H
eat
o
nlY
s
etuP
(n
o
o
utDoor
u
nIt
)
EXTREMELY IMPORTANT: The furnace only requires
a single W input for 2 stage gas heat control. Internal
algorithms will control staging of the gas furnace
automatically
1. Connect all necessary thermostat wires to the
thermostat connector on the furnace control as shown
in the following diagram.
R
C
G
Y
Optional
Optional
INDOOR
BOARD TERMINAL
CONNECTIONS
R
C
G
Y
24 VAC
Thermostat
1
2
C
Heat Pump
Optional
R
C
Y
n
on
-
coMMunIcatIng
sIngle
s
tage
H
eat
P
uMP
f
Igure
53
R
C
G
Y
Optional
Optional
INDOOR
BOARD TERMINAL
CONNECTIONS
R
C
G
Y
24 VAC
Thermostat
1
2
C
Two Stage
Heat Pump
R
C
Y
Y2
Y2
n
on
-
coMMunIcatIng
t
wo
s
tage
H
eat
P
uMP
f
Igure
54
2.
Download the
CoolCloud
HVAC phone application.
note: w
Hen
new
VersIons
of
B
luetootH
c
oMMunIcatIon
s
oftware
anD
f
urnace
c
ontrol
s
oftware
are
aVaIlaBle
,
tHe
PHone
aPPlIcatIon
notIfIes
tHe
user
. s
oftware
uPDates
are
classIfIeD
as
eItHer
oPtIonal
or
ManDatorY
anD
InstalleD
BY
usIng
tHe
PHone
aPPlIcatIon
. e
nsure
all
ManDatorY
software
uPDates
HaVe
Been
InstalleD
. r
eVIew
notes
for
oPtIonal
software
uPDates
anD
Install
If
necessarY
.
3. Select the Non-Comm Outdoor Setting menu (Od5)
using the on board push buttons or the
CoolCloud
HVAC phone application. Select 1 AC for single stage
Air Conditioners, 1HP for single stage heat pumps,
2 AC for two stage air conditioners and 2 HP for two
stage Heat Pumps.
4. Go to the tonnage units menu (ton) and select the
tonnage value that corresponds to the desired airflow
for the outdoor unit. See the following table.