background image

1

353AAV

Plus

90x

4--Way Multipoise Condensing Gas Furnace

Input Rates: 40,000 Only

Product Data

4--WAY MULTIPOISE DESIGN ALLOWS

MORE APPLICATIONS

A05085

A UNIQUE SEER SOLUTION

The

Plus

90x is an exciting addition to your product line. This

high--efficiency 4--way multipoise design furnace allows more

applications while the ECM motor and Bryant’s control logic

combine to provide a SEER increase of up to 1.5 points.*
Some of Bryant’s best--engineered components contribute to the

efficient performance of this condensing furnace. The

Plus

90x

utilizes Power Light

t

hot surface ignition (HSI), which ignites

the burners directly. HSI eliminates gas waste that typical

continuous--pilot designs can bring. Hot surface ignition has

proven to contribute to reliable start--up and operation of Bryant

furnaces.
Another deluxe feature included with this furnace is Bryant’s

trusted Everlastic

t

secondary heat exchanger; a patented

polypropylene laminate that provides exceptional heat transfer

and corrosion resistance. Using the exclusive flow--through

design, the secondary heat exchanger reduces the pressure drop in

the furnace resulting in lower electrical usage. The high

efficiency achieved by superior heat transfer is made only

better—by optimizing the efficient ECM motor speed tap

locations.
A standard media filter cabinet accessory is provided with the

Plus

90x in order to provide an opportunity to enhance indoor air

quality. As with all other Bryant furnaces, this model is designed

to work as a part of the total home comfort system which includes

elements for cooling, air cleaning, humidification, ventilation and

zoning. Boosting the unit’s efficiency with the ECM motor and

Bryant’s deluxe features show the

Plus

90x has been designed

with the homeowner in mind.

PLUS

90X FEATURES & BENEFITS

Everlastic

TM

— Exclusive Everlastic coating, a patented

polypropylene laminate is used on the secondary heat exchanger

and greatly reduces maintenance.

Perfect Light

Igniter

— Bryant’s unique Perfect Light

igniter is not only physically robust but it is also electrically

robust. It is capable of running at line voltage and does not

require complex voltage regulators as do other brands. This

unique feature further enhances the reliability of the

Plus

90x gas

furnace and continues Bryant’s tradition of technology leadership

and innovation in providing a reliable and durable product.

FanOn

— Improves comfort all year long by allowing the

homeowner to select different fan speeds during continuous fan

operation to achieve more or less airflow. This is done right at the

thermostat.

SmartEvap

— This feature allows your system to reduce

summertime humidity levels by nearly 10% over standard

systems.

Media Filter Cabinet

— Enhanced indoor air quality in your

home is made easier with our media filter cabinet—a standard

accessory on all Deluxe furnaces. When installed as a part of your

system, this cabinet allows for easy and convenient addition of a

Bryant high--efficiency air filter.

Control Center

— Microprocessor controls sequencing and

furnace operation. Equipped with a component test feature and

status indicator light to assist in troubleshooting. Microprocessor

controls blower times to start blower after main burners ignite to

eliminate cold air blowing into rooms.

*as compared to the Air---Conditioning, Heating and Refrigeration Institute’s standard coil---only rating (A/Cs up to 3.5 tons) when paired with selected Bryant

evaporator coils.

Содержание PLUS 90X 353AAV

Страница 1: ...oning Boosting the unit s efficiency with the ECM motor and Bryant s deluxe features show the Plus 90x has been designed with the homeowner in mind PLUS 90X FEATURES BENEFITS EverlasticTM Exclusive Ev...

Страница 2: ...smooth quiet combustion plus economical gas usage Slow Opening Redundant Gas Valve Shuts off gas to burners if any of the valves fails to close completely for any reason The slow opening feature reduc...

Страница 3: ...motor pulls hot flue gases through the heat exchangers maintaining negative pressure for added safety 10 Condensate drain connection collects moisture con densed during the combustion process 1 2 3 4...

Страница 4: ...NITION DEVICE Hot Surface DIRECT DRIVE MOTOR ECM X 13 1 2 1 2 1 2 3 4 1 1 MOTOR FULL LOAD AMPS 6 8 6 8 6 8 8 4 10 9 10 9 RPM Nominal SPEEDS 1050 5 BLOWER WHEEL DIAMETER X WIDTH IN mm 10 X 7 254 X 178...

Страница 5: ...For use with multi use stage configurations deg F C Auto Changeover Temperature and Humidity Control T6 PRH THERMOSTAT PROGRAMMABLE For use with 1 speed Air Conditioner deg F C Auto Changeover 7 Day...

Страница 6: ...dirt and many pollens commonly found Saves decorating and cleaning expenses by keeping carpets furniture and drapes cleaner Electronic air cleaner is shown A97432 CONTROLS THERMOSTATS AND ZONING Avai...

Страница 7: ...t furnace a For 800 CFM 16 in 406mm round or 14 1 2 368mm x 12 in 305mm rectangle b For 1200 CFM 20 in 508mm round or 14 1 2 368mm x 19 1 2 in 495mm rectangle c For 1600 CFM 22 in 559mm round or 14 1...

Страница 8: ...IPE APPLICATION SIZES 040 THROUGH 120 ONLY LENGTH OF STRAIGHT PIPE PORTION OF COMBUSTION AIR INLET PIPE ASSEMBLY IN mm CASING WIDTH A 17 1 2 8 1 2 1 2 216 13 mm 21 533 mm 10 1 2 1 2 267 13 mm 24 1 2 6...

Страница 9: ...5 635 24 610 23 5 8 600 mm 23 3 8 594 mm Furnace Side 23 3 4 603 mm Centerline Screw Slots 25 5 8 651 mm Duct Side 24 3 8 619 mm Opening with Flanges Bent 23 1 8 587 mm Opening 5 3 4 146 mm g n i n e...

Страница 10: ...10 CLEARANCE TO COMBUSTIBLES 335122 201 REV B LIT TOP A08435 353AAV...

Страница 11: ...39 30 60 17 33 30 60 17 33 40 70 22 39 CERTIFIED EX STATIC PRESSURE in wc Heating 0 10 0 12 0 15 0 15 0 20 0 20 Cooling 0 50 0 50 0 50 0 50 0 50 0 50 AIRFLOW CFM Heating 845 1040 1180 1450 1890 2065...

Страница 12: ...970 2 Org 1210 1180 1135 1085 1035 995 950 910 865 810 048080 SIDE BOTTOM 1 Red 1110 1065 1005 960 910 865 820 770 720 670 5 Gry 2070 2020 1985 1925 1890 1850 1795 1755 1690 1610 3 Blu 1815 1775 1730...

Страница 13: ...ric 2 1 2 64 one disk 2 1 2 64 10 3 0 NA NA NA NA NA 3 76 NA 45 13 7 40 12 2 35 10 7 30 9 1 25 7 6 20 6 1 3 76 no disk 3 76 70 21 3 70 21 3 70 21 3 70 21 3 70 21 3 70 21 3 ALTITUDE FT M UNIT SIZE BTUH...

Страница 14: ...3 4 38 11 6 31 9 4 NA 3 76 59 18 0 59 18 0 58 17 7 57 17 4 57 17 4 56 17 1 4 no disk 4 102 no disk 4 102 no disk 70 21 3 70 21 3 70 21 3 70 21 3 70 21 3 70 21 3 ALTITUDE FT M UNIT SIZE BTUH DIRECT VEN...

Страница 15: ...ntric 3 76 no disk NA 42 12 8 35 10 7 29 8 8 22 6 7 15 4 6 9 2 7 NA 3 76 53 16 2 52 15 8 50 15 2 49 14 9 48 14 6 47 14 3 4 102 no disk 4 102 no disk 70 21 3 70 21 3 70 21 3 70 21 3 70 21 3 70 21 3 ALT...

Страница 16: ...A 20 6 1 13 4 0 7 2 1 NA NA NA NA 3 76 46 14 0 44 13 4 43 13 1 41 12 5 40 12 2 38 11 6 4 102 no disk 4 102 no disk 61 18 6 56 17 1 51 15 5 46 14 0 41 12 5 36 11 0 ALTITUDE FT M UNIT SIZE BTUH DIRECT V...

Страница 17: ...isk 10 3 0 5 1 5 NA NA NA NA Disk usage Unless otherwise specified use perforated disk assembly factory supplied in loose parts bag If one disk is stated separate 2 halves of perforated disk assembly...

Страница 18: ...7 2 51 55 17 55 17 0 18 2 51 48 15 55 17 20 29 2 51 30 9 55 17 20 7 2 5 64 70 21 70 21 0 18 2 5 64 47 14 70 21 20 29 2 5 64 28 9 70 21 100 20 7 2 5 64 40 12 40 12 0 18 2 5 64 40 12 40 12 20 29 2 5 64...

Страница 19: ...Standard TYPICAL WIRING SCHEMATIC 115 V FIELD SUPPLIED DISCONNECT AUXILIARY J BOX 24 V TERMINAL BLOCK THREE WIRE HEATING ONLY FIVE WIRE NOTE 1 NOTE 2 FIELD SUPPLIED DISCONNECT CONDENSING UNIT TWO WIR...

Страница 20: ...CTRONIC AIR CLEANER AIRFLOW FRONT OF FURNACE COMBUSTION AIR INLET NON DIRECT 1 PIPE APPLICATION A05064 Upflow Application ELECTRONIC AIR CLEANER HUMIDIFIER A C COIL VENT COMBUSTION AIR DIRECT VENT 2 P...

Страница 21: ...VENT 2 PIPE APPLICATION COMBUSTION AIR INLET NON DIRECT VENT 1 PIPE APPLICATION A05066 Attic Horizontal Application COMBUSTION AIR PIPE DIRECT VENT 2 PIPE APPLICATION VENT PIPE ELECTRONIC AIR CLEANER...

Страница 22: ...ion ______________Media Filter Casing Casing shall be of 030 in 03 mm thickness minimum pre painted galvanized steel Inducer Motor Inducer motor shall be soft mounted to reduce vibration transmission...

Отзывы: