Testing Procedures 

 

!

WARNING

 

To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless  
testing requires it. 

©2003 Maytag Appliances Company

 16022506 

17 

 

“Quick Test” Mode for Electronic Range Control 

Follow procedure below to use the quick test mode. Entries must be made within 32 seconds of each other or the 
control will exit the quick test mode. 

1.  Press and hold CANCEL and BROIL pads for 3 seconds. 
2.  Once the control has entered the “Quick Test” mode, release both pads. 
3.  Press each of the following pads indicated in the table below. 

NOTE: 

First time one of following pads are pressed it will activate the response. 

The second time the pad is pressed it will deactivate the response. 

Display will indicate the following: 

Pad Response 

 

BAKE ................................... Bake DLB and Bake relay activated 
BROIL.................................. Broil DLB and Broil relay activated 
KEEP WARM ...................... Bake DLB and Broil DLB activated 
CONVECT BAKE ................ Convection Fan on high speed 
CONVECT ROAST ............. Cooling Fan activated 
CLEAN ................................ MDL relay activated 
COOK & HOLD ................... Displays last diagnostic code 
FAVORITE .......................... Displays EEPROM version number 
TIMER ................................. Displays main code version number 
CLOCK ................................ All display segments illuminated 
OVEN LIGHT....................... Oven light activated 
CANCEL .............................. Exit Quick Test mode 
1........................................... Even segments on 
2........................................... Odd segments on 
3........................................... Convection Ring activated; Convection Ring DLB activated 
4........................................... Bake relay activated 
5........................................... Broil relay activated 
6........................................... Convection relay activated 
7........................................... N/A 
8........................................... N/A 
9........................................... N/A 
AUTOSET ........................... Steps through last 5 diagnostic codes 

Description of Error Codes 

Error diagnostic codes can only be viewed by entering the Diagnostic Code Display Mode. 
Each error code is four digits long and is created based on the following table. 

Digit Description 

1

st

 

Primary System: 

1 – Local to the control circuit board 

 

3 – Sensor or meat probe 

 

4 – Control input 

 

9 – Door lock 

2

nd

 

Measurable: 

d – Diagnostic: measurable parameter 

 

c – Control related, replace control 

3

rd

 Secondary 

System: 

Sequential 

numbering 

4

th

 

Oven Cavity: 

1 – Upper oven (or single cavity oven) 

 

2 – Lower oven 

 

c – Control specific 

Diagnostic Code Display Mode can be activated by pressing and holding the AUTOSET pad for 3 seconds at  
power-up. Diagnostic Code Display Mode can only be started while powering up the control. 

Содержание AEW3530DD Series

Страница 1: ...130DD JJW8227DD JJW8230DD JJW8527DD JJW8530DD JJW8627DD JJW8630DD JJW9527DD Service This manual is to be used by qualified appliance technicians only Maytag does not assume any responsibility for prop...

Страница 2: ...ING REPAIRS WARNING To avoid risk of severe personal injury or death disconnect power before working servicing on appliance to avoid electrical shock To locate an authorized servicer please consult yo...

Страница 3: ...20 UH2Control 21 Test Mode 22 Description of Error Codes 23 DisassemblyProcedures RemovingandReplacingUnit 26 Control Panel Assembly 26 Control Board Assembly 26 TouchPanel 26 SideTrim s 26 StepdownT...

Страница 4: ...Do not let potholder touch burners Do not use a towel or other bulky cloth SELF CLEANING OVEN 1 Do Not Clean Door Gasket The door gasket is essential for a good seal Care should be taken not to rub d...

Страница 5: ...A Almond on Almond B Black C Brushed Chrome H Traditional White L Traditional Almond P Prostyle Q Monochromatic Bisque S Stainless T Traditional Bisque W White on White F Frost White True Color White...

Страница 6: ...bake Convection bake should be used for cooking casseroles and roasting meats Oven should be preheated for best results when using convection bake Pans do not need to be staggered Cooks approximately...

Страница 7: ...b Site at www amana com For Maytag Jenn Air product call 1 800 462 9824 or visit the Web Site at www maytag com or www jennair com For product in Canada call 1 866 587 2002 or visit the Web Sites at w...

Страница 8: ...working Power outage Verify power is present at unit Verify that the circuit breaker is not tripped Replace household fuse but do not fuse capacity Refer to Use and Care Manual Operating Instructions...

Страница 9: ...erminals 2600 W Approximately 21 cold 2800 W Approximately 20 cold 240 208 VAC Bake element Test continuity of terminals Test voltage to terminals Approximately 20 cold 240 208 VAC Broil element Test...

Страница 10: ...h depressed and changes stat as switch is rotated No continuity with switch at rest position Continuity with switch depressed and changes stat as switch is rotated NC NO C Door plunger switch Remove s...

Страница 11: ...Controlled Factory Default Press and hold Cancel and Keep Warm pads for 3 seconds Allows the clock to be reset to factory settings H1 Controlled Twelve hour off Control will automatically cancel any c...

Страница 12: ...l Clock Cook Hold Broil Bake Clean Keep Warm Favorite Timer Oven Light Trace 13 15 12 15 10 15 7 13 12 13 10 12 4 13 4 12 5 10 5 12 1 2 3 4 14 5 14 13 14 7 15 5 7 14 15 5 13 4 5 4 10 Measurement Conti...

Страница 13: ...Controlled Factory Default Press and hold Cancel and Keep Warm pads for 3 seconds Allows the clock to be reset to factory settings H2 Controlled Twelve hour off Control will automatically cancel any c...

Страница 14: ...nuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continu...

Страница 15: ...ke Lower Light Upper Keep Warm Upper Light Autoset Lower Keep Warm Conv Roast Lower Broil Upper Bake Timer 2 Cook Hold Upper Broil Timer 1 Trace 15 16 14 16 16 17 7 15 6 7 6 17 6 17 5 14 6 14 8 14 1 2...

Страница 16: ...equent changes to cooking parameters may alter it COOKING MODE BAKE BROIL CONVECT ELEMENT CONVECT FAN COOLING FAN OVEN LIGHT IDLE r r r r BAKE PREHEAT r r BAKE r r BROIL PREHEAT r r r BROIL r r r CLEA...

Страница 17: ...ay activated COOK HOLD Displays last diagnostic code FAVORITE Displays EEPROM version number TIMER Displays main code version number CLOCK All display segments illuminated OVEN LIGHT Oven light activa...

Страница 18: ...bles all outputs 1 2 Disables lights and timers 1c2c Keyboard loop improper value Nothing Disables audible for key depression Disables all outputs 1 Disables lights and timers 1c31 Cancel key improper...

Страница 19: ...position is achieved The unlock position may be identified by a successful unlock switch closure or as the result of timing when the unlock switch is not functioning properly If the last known good p...

Страница 20: ...Press SETUP pad Press DOWN ARROW pad to scroll to 12 HOUR SHUTOFF pad Select ON or OFF Select SET pad to activate Press SETUP pad to exit Allows the time on the clock to be toggled from 12 hour or 24...

Страница 21: ...utoff Press SETUP pad Press DOWN ARROW pad to scroll to 12 HOUR SHUTOFF pad Select ON or OFF Select SET pad to activate Press SETUP pad to exit Allows the time on the clock to be toggled from 12 hour...

Страница 22: ...he pad is pressed again Upon entering TEST Mode all relays are turned off except the DLB relays which are turned on All relays are turned off when the TEST Mode is exited Pad Pressed Relay or Action A...

Страница 23: ...0 F door locked Latch locked 1 minute 3d11 Temperature sensor failure open Cook or Clean active 20 sec 3d12 Temperature sensor failure open Cook or Clean active 20 sec 3d21 Temperature sensor failure...

Страница 24: ...ions for cavity 3d41 Probe resistance 0 mssg 1 active mssg 2 data Disable all probe functions 3d51 Calibration value out of range mssg 2 Disable all probe functions 4d11 Door switch not closed when do...

Страница 25: ...position is achieved The unlock position may be identified by a successful unlock switch closure or as the result of timing when the unlock switch is not functioning properly If the last known good p...

Страница 26: ...when disconnecting 6 Place control panel assembly on a protected surface 7 Reverse procedure to reassemble Control Board Assembly 1 Remove control panel see Control Panel Assembly procedure steps 1 t...

Страница 27: ...r or remove oven door see Door Removal 3 Remove screws securing sensor to oven cavity NOTE Gently pull wiring through cavity wall 4 Disconnect oven sensor at the connector block and remove 5 Replace a...

Страница 28: ...ls 6 Remove latch assembly or door light switch from chassis 7 Replace and reverse procedure to reassemble Lower Oven Door Latch Door Light Switch Assembly 1 Turn off power to unit 2 Remove top oven d...

Страница 29: ...cket and push socket assembly away from the oven cavity 10 Disconnect wires from light socket 11 Reverse procedure to reinstall light socket Reposition insulation around lamp socket NOTE Reposition fi...

Страница 30: ...Door Disassembly 1 Remove oven door see Oven Door Removal procedure 2 Place door on a protected surface 3 Remove screws securing bottom trim to oven door 4 Slide outer oven door glass and trim toward...

Страница 31: ...ng Disassembly Procedures 2003 Maytag Appliances Company 16022506 Rev 0 31 Door handle Door face assembly Insulation Bottom shield Glass window Door linner shield Window frame Glass window double coat...

Страница 32: ...2003 Maytag Appliances Company 16022506 A 1 Appendix A...

Страница 33: ...FP 0 1 0 1 WR WR 28 29 1 LD RQGXLW FFHVV ROH 3O ZRRG ORRU 0XVW 6XSSRUW OEV 6 1 29 1 LD RQGXLW FFHVV ROH 3O ZRRG ORRU 0XVW 6XSSRUW OEV 6 1 29 1 LD RQGXLW FFHVV ROH 3O ZRRG ORRU 0XVW 6XSSRUW OEV 0 16 21...

Страница 34: ...de It is advisable that the electrical wiring and hookup be accomplished by a competent electrician 120 240 VAC or 120 208 VAC 60 Hz See serial plate on front of unit for power requirements The neutra...

Страница 35: ...U 0XVW 6XSSRUW OEV 6 1 29 1 LD RQGXLW FFHVV ROH 3O ZRRG ORRU 0XVW 6XSSRUW OEV 6 1 29 1 LD RQGXLW FFHVV ROH 3O ZRRG ORRU 0XVW 6XSSRUW OEV 0 16 216 LQFKHV FP 0 1 0 1 0 1 WR WR 0 16 216 LQFKHV FP 0 1 0 1...

Страница 36: ...ower trim and reinstall screws al klq fkpq ii _lqqlj qofj rkqfi rkfq fp qq eba ql qeb _fkbqK b Unit to be properly circuit protected and wired according to local electrical code and National Electrica...

Страница 37: ...see Figure 1 then the hinge arm is not properly seated on the receiver Rotate the hinge locking lever DOWN to the unlocked position see Figure 2 and remove oven door as outlined in the Oven Door Remov...

Отзывы: