Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless
testing requires it.
©2003 Maytag Appliances Company
16022506
15
Maytag Matrix
Control Panel Assembly
Continuity is indicated as follows:
1000 – 6600
Ω
for Cancel pad
1000 – 15000
Ω
for All other pads
1
18
11
10
Pad
1
2
3
4
5
6
7
8
9
0
Lower Cancel
Upper Cancel
Conv Bake
Delay
Clock
Favorite
Lower Clean
Upper Clean
Lower Bake
Lower Light
Upper Keep Warm
Upper Light
Autoset
Lower Keep Warm
Conv Roast
Lower Broil
Upper Bake
Timer 2
Cook & Hold
Upper Broil
Timer 1
Trace
15 & 16
14 & 16
16 & 17
7 & 15
6 & 7
6 & 17
6 & 17
5 & 14
6 & 14
8 & 14
1 & 2
11 & 12
4 & 5
5 & 6
4 & 7
5 & 7
4 & 8
7 & 8
4 & 14
7 & 14
7 & 17
8 & 17
14 & 17
4 & 15
5 & 15
8 & 15
14 & 15
4 & 16
5 & 16
7 & 16
8 & 16
Measurement
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity