Electrical Information ___________

Electrical Requirements

All electrical connections must be made by a properly licensed 

electrician. This is to ensure that the electrical installation is 

adequate and conforms to local, state, and national regulations 

or codes of the country of destination. In the absence of such 

codes, all electrical connections, materials, and workmanship 

must conform to the applicable requirements of the National 

Electrical Code ANSI/NFPA NO. 70-LATEST EDITION or in 

Canada, the Canadian Electrical Codes Parts 1 & 2 CSA C22.1-

1990 or LATEST EDITION.

IMPORTANT:

 Failure to comply with these codes or 

ordinances, and/or the requirements stipulated in this manual 

can result in personal injury or component failure.

NOTE:

 Component failure due to improper installation will void 

the warranty.
Each pocket should be connected to an independently 

protected branch circuit. The dryer must be connected with 

copper wire only. Do not use aluminum wire. The copper 

conductor wire/cable must be of proper ampacity and 

insulation in accordance with electric codes for making all 

service connections.

NOTE:

 The use of aluminum wire will void the warranty.

An individual ground circuit must be provided to each pocket, 

do not daisy chain.
Component failure due to improper voltage application will void 

the warranty.
The manufacturer reserves the right to make changes in 

specifications at any time without notice or obligation.

IMPORTANT:

 A separate protected circuit must be provided to 

each pocket.
It is necessary to have a power disconnect for each pocket. 

These disconnects must be located within 30' (9 m) of the 

dryer and also be identified as being one of two power sources 

supplying a dryer.
The dryer must be connected to the electric supply shown on 

the data label.

Electrical Service Specifications

ELECTRICAL SERVICE SPECIFICATIONS (PER POCKET)

NOTES:

A.  When fuses are used they must be dual 

element, time delay, current limiting, class RK1 

or RK5 ONLY. Calculate/determine correct fuse 

value, by applying either local and/or National 

Electrical Codes to listed appliance amp draw 

data.

B.  Circuit breakers are thermal-magnetic 

(industrial) motor curve type ONLY. For others, 

calculate/verify correct breaker size according 

to appliance amp draw rating and type of 

breaker used.

SERVICE 

VOLTAGE

PHASE

WIRE

SERVICE

APPROX. 

AMP DRAW

CIRCUIT 

BREAKER

MINIMUM 

WIRE GAUGE

60 Hz

120

2

12

15

14

Grounding

A ground connection must be provided and installed in 

accordance with local, state, and national regulations or codes 

of the country of destination. In the absence of these codes, 

grounding must conform to applicable requirements of the 

National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION, 

or in Canada, the installation must conform to applicable 

Canada Standards: Canadian Electrical Codes Parts 1 & 2 CSA 

C22.1-1990 or LATEST EDITION. The ground connection may 

be to a proven earth ground at the location service panel.

Electrical Connections

A wiring diagram is located behind the control panel with 

connection data.
If local codes permit, power to the dryer can be made by the 

use of a flexible UL listed power cord/pigtail (wire size must 

conform to rating of dryer), or the dryer can be hard wired 

directly to the service breaker panel. In both cases, a strain 

relief must be installed where the wiring enters the dryer.

Single-Phase (1ø) Wiring Connections / Hookup

The electrical input connections are made into the rear service 

box located at the top of the dryer. To gain access, the service 

box cover must be removed. (Refer to the specification drawing 

in “Specifications” section of manual.)

Fire Hazard

Use appropriate gauge of copper wire (See chart in 
"Electrical Requirements" section).
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Electrically ground appliance per installation 
instructions.
Securely tighten all connections.
Failure to do so can result in death, fire, or electrical 
shock.

Содержание MLG45

Страница 1: ...MLG45 Installation Manual Stack Dryer WFR113489H RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE ...

Страница 2: ...ON HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Installation and service must be performed by a qualified installer service agency or the gas supplier Do not try to light any appliance Do not touch ...

Страница 3: ...sed to prevent straining of the gas supply when the dryer is moved An external means of power removal disconnect device must be provided by the installer The dryer must be used only for drying water washed fabrics The dryer must never be operated with any of the back guards or service panels removed The wiring diagram for the dryer is located behind the front control panel List of Acronyms _______...

Страница 4: ...Hz 600 cfm 16 99 cmm HEAT INPUT PER POCKET 112000 Btu hr 28224 kcal hr EXHAUST CONNECTION DIAMETER PER POCKET 2 8 Standard 1 10 Optional 2 20 32 cm 1 25 4 cm INLET PIPE CONNECTION PER POCKET 3 4 M N P T Shaded areas are stated in metric equivalents NOTE The manufacturer reserves the right to make changes in specifications at any time without notice or obligation NOTE Ductwork can be 2 8 20 32 cm o...

Страница 5: ...st conform to applicable Canadian Standards CAN CGA B149 1 M91 Natural Gas or CAN CGA B149 2 M91 Propane Gas or LATEST EDITION for General Installation and Gas Plumbing The operation of this dryer may affect the operation of other types of gas dryers which take their air for safe combustion from the same room If in doubt consult the dryer manufacturer s The dryer must be installed on a sound level...

Страница 6: ...r 1000 Btu 252 kcal It is not necessary to have a separate make up air opening for each dryer Common make up air openings are acceptable However they must be set up in such a manner that the make up air is distributed equally to all the dryers EXAMPLE For a bank of four dryers two unrestricted openings measuring 20 by 221 2 50 80 cm by 57 15 cm are acceptable To compensate for the use of registers...

Страница 7: ...hrough a wall ceiling or roof made of combustible materials the opening must be 2 5 08 cm larger than the duct all the way around The duct must be centered within this opening The ductwork for this dryer must be suitable for the appliance category in accordance with national installation regulations of the country of destination Outside Ductwork Protection To protect the outside end of the horizon...

Страница 8: ...the outdoors is longer than 20 6 09 m or has more than one elbow in it IMPORTANT For extended ductwork runs the crosssectional area of the ductwork can only be increased to an extent When the ductwork approaches the maximum limits as noted in this manual a professional HVAC firm should be consulted for proper venting information Multiple Dryer Venting with 10 25 4 cm Diameter 1200 cfm 33 98 cmm Ex...

Страница 9: ... When fuses are used they must be dual element time delay current limiting class RK1 or RK5 ONLY Calculate determine correct fuse value by applying either local and or National Electrical Codes to listed appliance amp draw data B Circuit breakers are thermal magnetic industrial motor curve type ONLY For others calculate verify correct breaker size according to appliance amp draw rating and type of...

Страница 10: ...nnections materials and workmanship conform to local and state regulations or codes of the country of destination In the absence of such codes all plumbing connections materials and workmanship must conform to the applicable local requirements In the USA this is the National Fuel Gas Code ANSI Z223 1 LATEST EDITION or in Canada the Canadian Installation Codes CAN CGA B149 1 M91 Natural Gas or CAN ...

Страница 11: ...eter Specific information regarding supply line size should be determined by the gas supplier NOTE Undersized gas supply piping can create a low or inconsistent pressure which will result in erratic operation of the burner ignition system TYPICAL NATURAL GAS INSTALLATION Consistent gas pressure is essential at all gas connections It is recommended that a 3 4 19 05 mm pipe gas loop be installed in ...

Страница 12: ...stment of the valve is complete the regulator cap must be replaced and sealed with for example paint to prevent tampering by the user Leak Check 1 Be sure the gas supply is turned on 2 Turn on dryer 3 Brush or spray an approved noncorrosive leak detection solution onto all connections and inspect for leaks indicated by growing bubbles 4 If dryer was moved during testing use the same method to chec...

Страница 13: ...ructions __________ The dryer is available for use when the appropriate side of the microprocessor display reads 0 minutes and the amount needed to start the dryer i e 25 Once the load has been put into the dryer and the main door is closed start the dryer as follows Insert the proper number of coins into the coin acceptor Once the correct Amount To Start has been inserted the display will read SE...

Страница 14: ... ducting and remove any lint buildup Suggested Cleaning Schedule Every Third or Fourth Load Clean the lint screen every third or fourth load A clogged lint screen will cause poor dryer performance The lint door drawer is located just below the loading door of the dryer Open the lint door drawer brush the lint off the lint screen and remove the lint Inspect lint screen and replace if torn NOTE To r...

Страница 15: ...s Gives the number drill size used 6 Electric Service This describes the voltage and current rating for a particular model 7 Gas Manifold Pressure For Gas Dryers This describes the manifold pressure taken at the gas valve tap SECHEUSES VOL 2 INPUT ENTREE ORIFICE ORIFICE MOD SER INPUT 0 TO 2 000 FT ENTREE 0 A 610M HEAT CHALEUR TYPE 120V 60HZ 1PH 2W 16A MANIFOLD PRESSURE PRESSION A LA TUBULURE D ALI...

Страница 16: ...MLG45 Manuel D installation Sécheuses Superposées CONSERVER CES INSTRUCTIONS POUR RÉFÉRENCE ULTÉRIEURE ...

Страница 17: ...structions à l usage du client en un lieu bien visible au cas où le client percevrait une odeur de gaz Ces renseignements doivent être obtenus auprès de votre fournisseur en gaz Placer l avertissement qui suit à un endroit bien visible Ne pas entreposer ou utiliser de l essence ou d autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil électroménager QUE FAI...

Страница 18: ...ISATION 28 INSTRUCTIONS D ARRÊT 28 RENSEIGNEMENTS SUR LA RÉPARATION ET LES PIÈCES 29 ENTRETIEN DE ROUTINE 29 INFORMATIONS SUR L ÉTIQUETTE DE DONNÉES 30 Attention Lors des contrôles d entretien placer des étiquettes sur l ensemble des câbles avant leur débranchement Des erreurs de câblage peuvent occasionner un fonctionnement incorrect Dans l État du Massachusetts les instructions d installation su...

Страница 19: ...TRÉE DE CHALEUR PAR SÉCHEUSE 112 000 Btu h 28 224 kcal h CONDUIT D ÉVACUATION DIAMÈTRE PAR SÉCHEUSE 2 8 po standard 1 10 po en option 2 20 32 cm 1 25 4 cm RACCORD D ENTRÉE DE TUYAU PAR SÉCHEUSE 3 4 po M N P T Les zones ombrées indiquent les dimensions en métrique REMARQUE Le fabricant se réserve le droit de modifier les spécifications à tout moment sans préavis ni obligation 8 po X2 OU 10 po EN OP...

Страница 20: ...91 gaz naturel ou CAN CGA B149 2 M91 gaz propane ou la DERNIÈRE ÉDITION pour l installation générale et la plomberie au gaz L utilisation de cette sécheuse peut affecter celle d autres sécheuses à gaz dont la source d approvisionnement en air se fait dans la même pièce pour une combustion sans danger En cas de doute consulter le fabricant de la sécheuse La sécheuse doit être installée sur un sol s...

Страница 21: ...ir d appoint distincte pour chaque sécheuse Les ouvertures communes pour l air d appoint sont acceptables Toutefois elles doivent être installées de sorte que l air d appoint est distribué uniformément à toutes les sécheuses EXEMPLE Pour une rangée de quatre sécheuses 2 ouvertures sans restriction de 20 po x 22 5 po 50 80 cm x 57 15 cm sont acceptables Pour compenser l utilisation de registres ou ...

Страница 22: ...e REMARQUE Lorsque les conduits d évacuation traversent un mur un plafond ou un toit en matériaux combustibles l ouverture doit être supérieure de 2 po 5 08 cm à celle du conduit tout autour Le conduit doit être centré dans cette ouverture Les conduits de cette sécheuse doivent être adaptés à la catégorie d appareils conformément aux réglementations nationales en matière d installation du pays de ...

Страница 23: ...d évacuation est plus long de 20 pi 6 09 m ou comporte plus d un coude IMPORTANT Pour les conduits de longueur prolongée l aire de la section transversale du conduit ne peut être augmentée que dans une certaine mesure Lorsque le nombre de conduits approche les limites maximales indiquées dans ce manuel il convient de faire appel à une entreprise de CVC professionnel pour obtenir des informations s...

Страница 24: ...utres calculez vérifiez la taille correcte du disjoncteur en fonction de l appel de courant de l appareil et du type de disjoncteur utilisé TENSION DE SERVICE PHASE SER VICE DE CÂBLAGE ENVIRON APPEL DE COURANT DISJONC TEUR CALIBRE DE FILS MINIMAL 60 Hz 120 1ø 2 12 15 14 Mise à la terre Une liaison à la terre doit être fournie et installée conformément aux réglementations ou codes locaux provinciau...

Страница 25: ...du National Fuel Gas Code ANSI Z223 1 DERNIÈRE ÉDITION ou au Canada des codes d installation canadiens CAN CGA B149 1 M91 gaz naturel ou CAN CGAB149 2 M91 gaz propane ou DERNIÈRE ÉDITION Il est important que les régulateurs de pression de gaz répondent aux exigences de pression applicables et que les compteurs de gaz soient calculés pour la quantité totale de Btu fournie de la sécheuse Pour facili...

Страница 26: ...ui entraînera un fonctionnement irrégulier du système d allumage du brûleur INSTALLATION TYPIQUE AU GAZ NATUREL Une pression de gaz constante est essentielle pour tous les raccordements de conduites de gaz Il est recommandé d installer une boucle de tuyauterie pour circulation de gaz de 3 4 po 19 05 mm dans la conduite d alimentation desservant une rangée de sécheuses Un détendeur doit être instal...

Страница 27: ...s fuites 1 Vérifier que l alimentation en gaz est ouverte 2 Mettre la sécheuse en marche 3 Appliquer au pinceau ou par pulvérisation une solution non corrosive de détection des fuites homologuée sur tous les raccordements rechercher les éventuelles fuites de gaz observables par la formation de bulles 4 Si la sécheuse a été déplacée pendant le test utiliser la même méthode pour vérifier l absence d...

Страница 28: ...structions d utilisation La sécheuse peut être utilisée lorsque le côté approprié de l afficheur du microprocesseur indique 0 minutes et le montant nécessaire pour démarrer la sécheuse c à d 25 Une fois que la charge a été mise dans la sécheuse et que la porte principale est fermée mettre la sécheuse en marche comme suit Insérer le nombre approprié de pièces dans le récepteur de pièces Une fois qu...

Страница 29: ...6 à 8 heures de fonctionnement par jour IMPORTANT S assurer de réinstaller les pièces retirées pendant le nettoyage Chaque 6 mois inspecter les conduits d évacuation et éliminer toute accumulation de charpie Programme de nettoyage suggéré Chaque troisième ou quatrième charge Nettoyer le filtre à charpie tous les trois ou quatre charges Un filtre à charpie obstrué entraînera une mauvaise performanc...

Страница 30: ... fabricant de rassembler des informations sur votre sécheuse particulière 3 Type de chaleur Ceci décrit le type de chaleur de votre sécheuse gaz gaz naturel ou propane électrique ou vapeur 4 Apport de chaleur pour les sécheuses à gaz Ceci décrit l apport de chaleur en unités thermiques britanniques par heure Btu h ou kilowatt kW 5 Taille de l orifice pour les sécheuses à gaz Donne le nombre de for...

Страница 31: ...31 ...

Страница 32: ...WFR113489H 03 20 Tous droits réservés 2020 Maytag All rights reserved ...

Отзывы: