Operating Instructions USi 

Page 41/43

Polymer Electric

Glossary

is connected. The analog output OUT°1.1 can also be assigned an inverted output 
signal via the parameter assignment software (optional). (

cf. Output, OUT)

Output digital

 

Semi-conductor of type PNP. Each output can be an NO contact, an NC contact or 
Off. The digital output is preset as NO contact in delivery condition. A changeover 
is implemented, e.g., by de

fi

ning output 1.1 as a normally open contact and output 

1.2 as a normally closed contact. The digital outputs are de

fi

ned via the parameter 

assignment software (optional) (cf. Output, OUT, PNP)

Parameter assignment 
software

 

Optional software, with which all 

USi 

parameters can be changed via a Windows

®

 

interface and transmitted via USB interface to the USi. The parameter assignment 
software allocates the three modes 

Standard

Expert mode

 and 

Diagnosis

.

PNP

 

Transistor 

output

 Type PNP.

Proximity switch

 

Position switch, which is activated without mechanical contact with the moving  
object. [IEC

 

60947-5-2, 2.1.1] (cf. 

Ultrasonic proximity switch

)

Real switching distance

 

Switching distance

 of an individual 

proximity switch

, which is measured at speci

fi

temperature, voltage and installation conditions. [IEC

 

60947-5-2, 2.3.1.5]

Reference axis

 

Axis, which runs perpendicularly to the 

active surface

 and through its centre. 

[IEC

 

60947-5-2, 2.2.2.1] (cf. 

Opening angle

)

Reference object

 

Speci

fi

ed part, which is used for comparative measurements of the 

switch points

 

and the 

detection fields

. Synonymous with 

measurement object

.

Re

fl

ex barrier

 

Extended function of an 

ultrasonic proximity switch

. The 

USi

 monitors the area 

between 

switch point SP1

 and a taught-in re

fl

ector. Each change results in signal 

change at the 

output

. (cf. 

Sonic barrier

)

Re

fl

ex switch

 

Basic function of an 

ultrasonic proximity switch

Objects

 in the 

detection 

fi

eld

 will 

be detected, meaning sensed using the 

sonic lobe

.

Repeatability

 

Make a change to the 

real switching point

 under predetermined conditions. 

[IEC

 

60947-5-2, 2.3.4] Indicates the accuracy of measurement results, which have 

passed through the same 

switch point

 with predetermined conditions. Synonymous 

with reproducibility.

RESET

 

Function with which the 

USi

 is set back to the 

delivery condition.

 Subsequently,  

the 

USi

 will start with the 

factory settings

.

Resolution

 

Smallest unit of length, which can be differentiated by a 

proximity switch

. Resolu-

tion of the USi: 1

 

mm. (cf. 

Measurement

 

resolution

)

Secondary object

 

Object

 in the 

detection field

, which is not an 

object

 to be detected. Examples:  

machine parts, shelves, columns, etc. In order to prevent malfunctions, the 

USi

 will 

be subjected to a 

Teach

 

In

 of the environment incl. all secondary objects.  

(cf. 

Object

)

Содержание 1005264

Страница 1: ...Y Tel 49 731 2061 0 Fax 49 731 2061 222 E Mail info ulm mayser com Internet www mayser com Operating Instructions Original instructions Ultrasonic Industrial Sensor USi Master Slave USi PP 1005632 100...

Страница 2: ...a Sensor analog 13 Operating Mode 1 Range 13 Operating Mode Window 14 Examples of Use 15 Installation 17 Mounting the Sensor Ultrasonic Transducer 17 Alternative Enclosure set optional 18 Mounting th...

Страница 3: ...ating instructions carefully before use Keep operating instructions for the complete service life of the product Pass operating instructions on to every subsequent owner or user of the product Add any...

Страница 4: ...ne step where the order is rel evant r Bullets first level Bullets second level see Installation Cross reference Symbols used Symbol Meaning DANGER Immediate danger leading to death or serious injury...

Страница 5: ...not possible The product is not authorised for use in these areas r Objects with a highly sound absorbing surface such as open pore foam cordu roy etc cannot be reliably detected r Objects with an ext...

Страница 6: ...General Requirements These Operating Instructions were drawn up in compliance with IEC 62079 Prepa ration of Instructions Structuring Content and Presentation In the event of a fault take out of opera...

Страница 7: ...The sensors ultrasonic transducers are packaged in a protective pressure lock bag The documents are enclosed separately Packaging and transport Transport and storage Parts supplied 1 Evaluation Unit...

Страница 8: ...has a fixed length of 1 5 m and may not be lengthened or shortened Should the 1 5 m not be sufficient the cable length can be doubled using the optional extension cable 1005903 1 Ultrasonic transduce...

Страница 9: ...1 ultrasonic transducer 1 Sensor 2 M8 3 poled Sensor 2 ultrasonic transducer 2 Connections Plug X1 Signal PIN Circular connector Supply voltage US US 2 7 M12 Output 1 1 OUT 1 1 1 Output 1 2 OUT 1 2 3...

Страница 10: ...upply voltage US US 2 7 BN BU Brown Blue Output 1 1 OUT 1 1 1 WH White Output 1 2 OUT 1 2 3 GN Green Output 2 1 OUT 2 1 4 YW Yellow Output 2 2 OUT 2 2 5 GY Grey not assigned 6 PK Pink Synchronisation...

Страница 11: ...281114 v1 3 Operating Instructions USi Page 11 43 Polymer Electric Product overview Sonic lobe spatially Opening angle 6 dB narrow side Reference axis Opening angle 6 dB broad side Reference axis...

Страница 12: ...e SP1 1 cm SP2 200 cm Since switch point SP1 complies with the minimum switching distance of only 1 cm detection is effectively from the active surface to the switch point SP2 If an ob ject penetrates...

Страница 13: ...is only available for USi with analog output The 2 possible operating modes are Operating Mode 1 Range Operating mode 1 Range is the preset standard operating mode SP1 1 cm SP2 200 cm Since switch poi...

Страница 14: ...distant detection field extends from the switch point SP1 to the switch point SP2 If an object penetrates the detection field further away from the sensor the outputs preset as normally open contacts...

Страница 15: ...Position check Is a defined position reached 6 Operating mode 1 range and teach in Distance detection 7 Distance check When is a defined distance not reached 8 2 zone observation Has an object penetr...

Страница 16: ...When is a defined distance to the obstacle fall so far short SP1 that action must be taken 11 Operating mode 1 range 12 Operating mode 2 ranges and specification of the switch points SP1 and SP2 Area...

Страница 17: ...l 20 crackles per second are audible This can be stressful when continu ous Here it is recommended to not align the sensor directly to the ears but at an angle of at least 20 The same applies for indi...

Страница 18: ...ernative Enclosure set optional Instead of using your own brackets you can also use one of the Mayser enclosure sets See Chapter Accessories for a small selection The installation steps are the same a...

Страница 19: ...ny position on a 35 mm mounting rail IEC 60715 Wiring the Unit Cable Danger of injury due to electrocution Disconnect all devices and live parts in the immediate environment of the power supply and pr...

Страница 20: ...tions USi 281114 v1 3 Polymer Electric Installation Failure due to incorrect wiring Carefully check the wiring Inspect the supply voltage CAUTION Impaired operation due to missing grounding Carefully...

Страница 21: ...n immediately namely independently of the existing functional parameters At the first initialisation following delivery the USi starts with the functional parame ters preset in the factory the factory...

Страница 22: ...1 1 output 1 2 is closed Yellow LEDs OUT 2 and OUT 2 2 are off Outputs 2 1 and 2 2 are open 1 Make sure that the detection fields from sensor 1 and sensor 2 are clear Green LED Power is lit All yello...

Страница 23: ...ere this includes you and your limbs 3 Keep the Teach In button pressed down until the green LED Power starts to flash 1 Hz 4 Now release the Teach In button The green LED Power now flashes faster 5 H...

Страница 24: ...or 1 or for Sensor 2 5 Release the Teach In button as soon as all the yellow LEDs OUT of the corresponding sensor is lit for the switch points that you want to set Now the yellow LED OUT X 2 is lit an...

Страница 25: ...imum distance of 1 cm for switch point SP1 TIP Cancel After Step 5 cancellation is only possible by disconnection of the supply voltage Logon logoff Sensor 2 The USi is preset to one sensor ultrasonic...

Страница 26: ...el the function Logon logoff Sensor 2 after a period of 10 s 5 Now press the Teach In button 0 5 s The USi signalises that Sensor 2 is now logged off by the continuously lit yellow LEDs OUT for 1 s 6...

Страница 27: ...10 s Note If the Teach In button is not pressed the USi will automatically cancel the function RESET after a period of 10 s 5 Press the Teach In button 0 5 s The USi signalises that the RESET is exec...

Страница 28: ...ield the USi from the source of electromagnetic interference 3 Earth the Evaluation Unit Acoustic interference 1 When possible eliminate the interfe rence 2 Reconfigure the sensor 3 Move the sensor Gr...

Страница 29: ...outputs correctly The object is not detected The object is outside of the detection field Check the limits of the detection field with a test object Object has sound absorbing structure Check the acou...

Страница 30: ...sensor 2 Apply multisensors master slave software Reciprocal interference from sensors Apply multisensors master slave software Direct sunlight on the Evaluation Unit Shield the Evaluation Unit Elect...

Страница 31: ...ugs for USi Evaluation Unit 1005377 Sensor ultrasonic transducer ps mt 18x4 m with 1 5 m cable 1005264 Accessories Designation Part number O Ring Set 18 2 5 mm for ultrasonic transducer to mount in st...

Страница 32: ...ting of 1 Enclosure horizontal 2 O Ring 17 5 2 0 mm 7502905 Enclosure set vertical for Ultrasonic transducer consisting of 1 Enclosure vertical 2 O Ring 17 5 2 0 mm 7502906 Extension cable for sensor...

Страница 33: ...llow the enclosure to dry before recommissioning Danger of injury due to electrocution Disconnect the USi as well as all devices and live parts in the immediate environment from the power supply and p...

Страница 34: ...be disposed of at the collection centres of public sector disposal organisations e g municipal recycling depots At the end of their useful life the devices may be returned to us for disposal WEEE reg...

Страница 35: ...cm Device synchronisation Off Expert mode Echo gain 5 Sensitivity 5 Multiple scan 3 Power on delay 10 Close range to 16 cm Echo distribution from 50 cm Hysteresis 0 cm Object size Medium Object detect...

Страница 36: ...ection Size min Speed axial max Repeatability Hysteresis Temperature compensation without Temperature drift with Ultrasonic pulse echo procedure combined echo runtime and Echo amplitude measurement 10...

Страница 37: ...r output DC 30 V Safety classifications Electrostatic discharge protection in compliance with interference immunity against high frequency electromagnetic fields in compliance with interference immuni...

Страница 38: ...Evaluation Unit for faults which are determined during initialisation Distance The space between two points First point of the USi is the active surface second point is the detected object cf Measurem...

Страница 39: ...asurement distance Distance between active surface and detected object The minimum measurement distance is equal to the minimum switching distance the maximum measurement distance is equal to the moni...

Страница 40: ...e minimum switch ing distance The detection field extends from 1 Range from minimum switching distance on to switch point 2 Operating mode 2 Ranges USi operating mode where the detection field is divi...

Страница 41: ...ence axis Axis which runs perpendicularly to the active surface and through its centre IEC 60947 5 2 2 2 2 1 cf Opening angle Reference object Specified part which is used for comparative measurements...

Страница 42: ...oximity switch Supply voltage Voltage which is externally connected to a device in order to enable its operation The supply voltage should correspond to the connecting voltage indicated on the type pl...

Страница 43: ...sonic temperature drift is generally balanced by inter nal temperature compensation cf Temperature compensation Transducer Abbreviated name for ultrasonic transducer Referred to as sensor for USi cf S...

Отзывы: