081222 v2.11-RiA
Operating instructions SG-EFS 104/2W
Page 19/19
Technical data
SG-EFS 104/2W
AC 24 V
DC 24 V
Outputs
OSSDs 1 and 2 (NO contact)
13, 14 and 23, 24
13, 14 and 23, 24
Signal circuit (NC contact)
41, 42
41, 42
Utilisation category
AC-12: 250 V / 4 A
AC-12: 250 V / 4 A
in accordance with
IEC 60947-5-1
DC-12: 24 V / 4 A
DC-12: 24 V / 4 A
Switching voltage (max.)
AC 250 V DC 24 V
AC 250 V DC 24 V
Switching current (max.)
4 A
4 A
4 A
4 A
Switching capacity (max.)
1000 VA 96 W
1000 VA 96 W
Switching operations,
mechanical
> 1× 10
7
> 1× 10
7
Switching operations,
electrical
> 3.6× 10
5
(DC 24 V / 1 A)
> 3.6× 10
5
(DC 24 V / 1 A)
External contact fuse
protection
6.3 A quick-acting
6.3 A quick-acting
Line length (max.)
30 m
30 m
Signal output (PNP)
M1, S1
M2, S1
M1, A2
M2, A2
Signal type
Sensor Fault
Sensor Fault
Voltage
DC 20 to 29 V
DC 20 to 29 V
DC 18 to 22 V
DC 18 to 22 V
Load current (max.)
100 mA 100 mA
100 mA 100 mA
Line length (max.)
30 m
30 m
30 m
30 m
Mechanical operating conditions
Cable terminals
4× 4-pin
4× 4-pin
Solid wire
1× 2.5 mm
2
or 2× 1.5 mm
2
1× 2.5 mm
2
or 2× 1.5 mm
2
Wire with sleeve
1× 2.5 mm
2
or 2× 1.5 mm
2
1× 2.5 mm
2
or 2× 1.5 mm
2
IEC 60529: degree of protection
IP20
IP20
Max. humidity (23 °C)
95%
95%
Operating temperature
−25 °C to +55 °C
−25 °C to +55 °C
Storage temperature
−25 °C to +55 °C
−25 °C to +55 °C
Impact resistance in operation
2.5 g
2.5 g
2006/42/EC and
UK S.I. 2008 No. 1597:
Emission sound pressure level < 70 dB(A)
< 70 dB(A)
Dimensions (W × H × D)
22.5 × 99 × 114.5 mm
22.5 × 99 ×114.5 mm
Weight
180 g
180 g