Installation and operational instructions for
ROBA
®
-servostop
®
Type 8982.00_01
Size 40
– 100
(B.8982.EN)
06/10/2022 GF
Chr. Mayr GmbH + Co. KG
Eichenstraße 1, D-87665 Mauerstetten
Phone: +49 8341 804-0, Fax: +49 8341 804-421
Page 27 of 27
your reliable partner
16
Malfunctions / Breakdowns
Malfunction
Possible Causes
Solutions
Brake does not release
Incorrect voltage on rectifier
No power
Air gap too large (worn rotor)
Coil interrupted
Screws in thread s
1
too long
Apply correct voltage
Replace the power supply
Replace the brake
Select the correct screw length
Mayr
®
power transmission will take no responsibility or guarantee for replacement parts and accessories
which have not been delivered by
mayr
®
power
transmission, or for damage resulting from the use of these
products.