5.2.6
Switching Times
Diagram 1
Switching times for brake operation with overexcitation voltage
Key
M
Br
= Braking torque
M
L
= Load torque
t
1
= Connection time
t
11
= Response delay on connection
t
2
= Separation time
t
O
= Overexcitation time
U
N
= Coil nominal voltage/coil voltage
U
H
= Holding voltage
U
O
= Overexcitation voltage
(These values are mean values
referring to a nominal air gap „a“ on a cold brake)
Switching Times
Size
40
50
60
70
80
90
100
Connection time
DC-side switching
t
1
[ms]
15
15
15
20
20
30
30
AC-side switching
t
1
[ms]
65
65
65
80
90
150
150
Response delay on
connection
DC-side switching
t
11
[ms]
10
10
10
15
15
20
20
AC-side switching
t
11
[ms]
50
50
50
60
60
100
100
Separation time (release)
t
2
[ms]
25
25
35
50
70
70
70
Overexcitation time
t
O
[ms]
50
50
70
100
140
140
140
U
O
M
Br
0,1 x M
Br
M
L
t
11
t
1
t
2
t
O
U
M
t
t
U
H