background image

 

 

 
 
 

eMAX-MR51e

 

READER INTERFACE MODULE

 

 

Installation Guide and Specifications  

 
 

 

 

 

 

 

 

 

 

This device complies with FCC Part 15, Class A Specifications. 
The device meets CE Specifications, and is RoHS Certified.  

This device is UL 294 Recognized.  

 

 

 

 

 

 

 

August, 2012

 

Содержание eMAX-MR51e

Страница 1: ...INTERFACE MODULE Installation Guide and Specifications This device complies with FCC Part 15 Class A Specifications The device meets CE Specifications and is RoHS Certified This device is UL 294 Recog...

Страница 2: ...put Circuit Wiring 8 9 Status LEDs 10 10 Configuring the eMAX MR51e 10 11 Specifications 11 12 Mounting Information 3 Gang Electrical Box 12 13 Enclosure Mounting 14 Change History Revision A Document...

Страница 3: ...2 Card Reader connection ports The first reader port can accommodate a reader that utilizes Wiegand data0 data1 Magnetic Stripe clock data or 2 wire RS 485 electrical signaling standards as well as o...

Страница 4: ...HERNET STATUS LEDs RELAY K1 LED RELAY K2 LED STATUS LEDs SOLDER SIDE 2 3 4 1 S1 S2 1 2 3 4 5 6 ON J3 J7 K1 K2 12V J5 PoE J6 TB1 TB2 TB3 TB4 TB5 TB6 1 1 1 1 1 1 IN1 IN2 IN3 IN4 VO LEDBZRCLKDATGND VO GN...

Страница 5: ...6 GND Reader 1 Ground TB4 1 LED Reader 2 LED Output TB4 2 BZR Reader 2 Buzzer Output TB4 3 CLK Reader 2 CLK Data 1 Input TB4 4 DAT Reader 2 DAT Data 0 Input TB5 1 VO Auxiliary Power Output 12Vdc TB5...

Страница 6: ...ways jumper selected Power can be supplied via the Ethernet connection using Power over Ethernet PoE fully compliant to IEEE 802 3af OR Power can be supplied via a local 12Vdc power supply minimum 1A...

Страница 7: ...ort supports Wiegand and magnetic stripe electrical interfaces Power to the first reader is 12Vdc and is current limited to 150mA The second reader may be powered from the auxiliary power output on TB...

Страница 8: ...sistors and should be located as close to the sensor as possible Note Grounded and foreign voltage states are not a requirement of UL 294 and therefore not verified by UL The input circuit wiring conf...

Страница 9: ...RMS For 24Vac strike Panasonic ERZ C07DK470 typical See documentation included with locking device regarding suppression diode requirements NOTE It is possible for the eMAX MR51e to provide power for...

Страница 10: ...ON 1 On line encryption disabled 8 second ON 2 second OFF On line encryption enabled four pulses 1 second ON 1 second OFF per second 2 Flashes when there is host communication 3 Flashes when data is r...

Страница 11: ...power out TB5 12 Vdc 10 7 through 13 0 700mA maximum Outputs 2 Relay Outputs Form C contacts rated at 5A 28Vdc Inputs 4 unsupervised supervised End of Line resistors 1k 1k ohm 1 4W watt 1 standard res...

Страница 12: ...bracket 5 3 oz 150g with bracket Environment Temperature 55 C to 85 C storage 0 C to 70 C operating Humidity 10 to 95 Relative Humidity non condensing 12 Mounting Information 3 Gang Electrical Box So...

Страница 13: ...August 20 2012 eMAX MR51e Man Rev B 13 of 17 Mounting Plate Dimensions...

Страница 14: ...four eMAX MR51e panels will allow space for battery backup Sheet metal screws are included with the eMAX EP1501 for mounting The eMAX EP1501 mounts in the holes marked A1 through A6 Legend A1 through...

Страница 15: ...anels per Large enclosure Sheet metal screws are included with the eMAX EP1501 for mounting The eMAX EP1501 mounts in the holes marked A1 through A8 Legend A1 through A8 Mounting holes for EP1501 or M...

Страница 16: ...track fit per enclosure and allows space for the power supply and battery backup Din rail mounting kits are sold separately A A A B B B B B B B B B B C C C C D E E E E E A B C D E Housing Mounting Hol...

Страница 17: ...nties implied or otherwise and expressly excludes and disclaims all implied warranties of merchantability or fitness for a particular purpose Returned units are repaired or replaced from a stock of re...

Отзывы: