User Manual
G
eneral
d
escription
Display: LCD screen with background, max reading of
“1999”
Operating temperature:
0°C - 40°C
(32°F
-
104°F)
Operating humidity:
<80% RH
Storage temperature:
-10°C - 60°C
(14°F
-
122°F)
Storage humidity:
<70% RH
Sampling updates:
2/mp
Measurement range selection: automatic or manual
Clamp Jaw Opening:
26 mm
Measurement category:
Cat III 600V
Power Source:
2x AAA 1,5V battery
Size:
194 x 72 x 35 mm
Weight:
~230g (with battery)
Overload Protection and Overvoltage Protection
Auto Turn On/Off function
Data Hold Function
s
afety
inforMation
This User’s Guide contains the safety information and
guidelines to use the Meter correctly. To prevent pos-
sible electrical shock or damage in the Meter, please
follow these guidelines while operating the Meter.
Warning!
Read and understand this user manual before you use
the Meter.
Follow the safety information and user’s guidelines to
secure personal safety and prevent electrical shock whi-
le using the Meter.
•
Do not exceed the maximum allowable input ran-
ge of any function.
•
Do not use the Meter around explosive gas, va-
pour or in damp or wet environments.
•
Do not use the Meter if its outside or your hands
are wet.
•
Never open the battery cover while operating the
Meter.
•
Inspect the condition of the test leads and the
Meter itself for any damage before operating the
Meter.
•
Repair or replace any damage before use.
•
Do not rotate the function switch until connecting
the Meter to current.
•
Do not use unspecified replacement parts, and do
not modify the current circuit of the Meter.
•
Have the Meter serviced only by qualified service
personnel.
•
Always turn the device off and remove test leads
before replacing the battery.
•
Do not replace battery if the Meter or your hands
are wet.
•
Ensure that you set the function switch onto the
right position before operating the Meter.
•
Do not expose the equipment to the sunlight or
wet and/or dusty environment.
•
To avoid false readings, replace the batteries as
soon as the low battery indicator
appears.
OFF
200A
600A
2A
20A
LINE
NCV
AUTO POWER OFF
MC 25610
Ω
V
V
°C°F
CLAMP METER
COM
MAX 600V
INPUT
RST RAN MAXH SEL
1 . „NCV” sensor/tip
2. Current Clamp
3. „NCV” LED function indicator
4. Clamp opening trigger
5. Function rotary switch
6. LCD display
7. Function buttons
- SEL – SELECT, measurement selector in functions
- RAN – RANGE, switch to manual measurements
- RST – RESET, device reset
- MAXH, MAX HOLD, maximum data hold function
8. INPUT – test lead input jack/terminal
9. COM – terminal/input jack
f
Unctions
HOLD button
Data hold function. To hold the present reading, press
the data hold button for a while. Press the button again
to resume normal operation.
MAX HOLD button
Maximum data hold function. To hold and record the
present reading, press the MAXH button for a while.
The measured reading will not change until the devi-
ce does not measure a higher measurement. The MAX
HOLD function can be turned off by pressing this but-
ton longer.
RANGE button
To select auto-range or manual range modes.
Press the RAN button to change between auto- or ma-
nual range modes. Press the button repeatedly to select
different ranges. Press the button for longer and the de-
vice will turn back to auto-range mode.
SELECT button
By the SEL button, you can select the functions within
the ranges of the function rotary switch
1
2
3
4
5
6
7
8