SCSI Description
Maxtor Atlas 15K
5-43
5.14.5
Unit Attention Condition Page (00h)
The Unit Attention Page is used to enable or disable the generation of Unit Attention
Conditions. The Unit Attention Condition Page format and field descriptions are
described in Table 5-60 and Table 5-61 respectively.
Table 5-60
Unit Attention Condition Page (Page 0)
Table 5-61
Unit Attention Condition Page (Page 0)
Bit
Byte
7
6
5
4
3
2
1
0
0
PS
Rsvd
Page Code (00h)
1
Page Length (02h)
2
Reserved
DUA
Reserved
3
Reserved (00h)
Field
Default Value
Description
PS
1
Parameters Savable. This bit is only used with the MODE SENSE com-
mand. A returned value of 1 indicates that the target is capable of sav-
ing the page in a non-volatile, vendor-specific location. The bit is
reserved with the MODE SELECT command.
DUA
0
Disable Unit Attention. When set to the default value of 0, the drive re-
ports a CHECK CONDITION for any UNIT ATTENTION condition
(power-on, SCSI bus reset, etc.)
Содержание Atlas SCSI Drive 15K II
Страница 1: ...Maxtor Atlas 15K Product Manual ...
Страница 2: ...Maxtor Atlas 15K Product Manual April 29 2003 PN 1880 ...
Страница 6: ......
Страница 12: ...Table of Contents xii Maxtor Atlas 15K ...
Страница 14: ...List of Figures xiv Maxtor Atlas 15K ...
Страница 24: ...About This Manual 1 4 Maxtor Atlas 15K ...
Страница 53: ...Installation Maxtor Atlas 15K 3 25 Figure 3 9 Crosswise Airflow Cooling ...
Страница 54: ...Installation 3 26 Maxtor Atlas 15K ...
Страница 66: ...Specifications 4 12 Maxtor Atlas 15K ...
Страница 232: ...Feature Descriptions 6 16 Maxtor Atlas 15K ...
Страница 238: ...Appendix A A 6 Maxtor Atlas 15K ...
Страница 253: ...Glossary G 13 Maxtor Atlas 15K ...
Страница 254: ...Glossary G 14 Maxtor Atlas 15K ...
Страница 260: ...Index I 6 Maxtor Atlas 15K ...