6
2.5 Enroll the PC4164-RS
You must enroll the PC4164-RS module with the PC4010/4020 panel, before you
can install and program the WLS9XX devices. The PC4164-RS will reserve up to 56
zones on a PC4010 and up to 64 zones on a PC4020 for wireless use.
To make sure you have enough space for hardwire zones, you should enroll the
PC4164-RS after you have enrolled all the hardwire zone expander modules. For
example, if you enroll the PC4164-RS first on a PC4020, it would use up zones 17 to
80, leaving only 48 spots left for hardwire zone expander modules.
NOTE
: You cannot have more than 64 zones on the PC4010 and 128 zones on the
PC4020. If the total number of zones theoretically available on the zone expanders
exceeds the maximum for the panel, you will not be able to use the extra zones.
A description of how to enroll keypads and modules is in your PC4010/4020
Installation Manual, section 4: Module Enrollment.
Follow these steps to enroll your PC4164-RS module.
1. At a PC4010/4020 system LCD keypad, enter [*][8][Installer’s code] to go to
the Installer’s Programming section.
2. Enter Ref #[0200], to go to the Enroll Module section.
3
Scroll to PC41XX Zn. Ex., press [*]. The LCD keypad will display
Create Tamper on Desired Unit
.
4. Tamper the PC4164-RS:
i) make sure the connection between the T1 and T2 tamper terminals is closed
(tamper zone secured) (see Diagram 1).
ii) open the normally closed contact, if present, or remove the wiring from one
of the tamper terminals (tamper zone violated). The change from secure to
violated will enroll the module.
The LCD keypad will display PC4164 Zn. Ex. Mod XX Enrolled.
5. When the module is enrolled, re-secure the connection between the T1 and T2
terminals.
6. Press [#]. The LCD keypad will display Zones XXX - XXX. Record the zone
number range for the module in the worksheets.
7. To exit module enrollment, press [#].
The PC4164-RS module is now installed and enrolled on the PC4010/4020 system. You
can now enroll and program the wireless devices. How to do this is described in Section 3.
G E T T I N G S T A R T E D