In4G User Manual
- 78 -
Battery Level for Module Deregistration (12.3 volts ON, 11.9 volts OFF)
0,1~20 LCP Echo Interval (seconds)
0,1~10 LCP Echo Failure (counts)
OK
Note
: The Dialup Number cannot be left blank.
Periodic reset
AT$$RESET=24 (setting between 1 and 28 hours)
$$RESET: 24
OK
Parameters
$$RESET: X
0 ~ 24 Hours of Periodic reset
WAN scheduler
AT$$WANSS?
$$WANSS: 0,Disabled
OK
Parameters
$$WANSS:
0,1 RS232 line driver power down
0,1,2 Disable/Day of Week/Duration
0,1 Delete/Add schedule/5~59 Minutes of power up
0~28 Entry number of day of week/0,1, 2,3,4,5,6 Day of week/5~59 Minutes of power
cycle
0~23 Hours of start
0~59 Minutes of start
0~23 Hours of finish
0~59 Minutes of finish
0,1 Engine power down
OK