background image

Low temperature burners  - INDITHERM

®

w w w . m a x o n c o r p . c o m

combustion systems for industry

MAXON  reserves the right to alter specifications and data without prior notice. 
© 2008 Copyright Maxon Corporation.  All rights reserved.

1 - 2.3 -

16

E - m - 7/08

Gaskets - GSK- INDI

These gaskets are used to seal the mounting plate of the burner and the duct wall. Optionally available in 2 different types:

„

GSK-INDI-STD to be used in combination with standard discharge sleeves (square)

„

GSK-INDI-HT to be used in combination with high temperature discharge sleeves (round)

Gasket type

Burner Type

Geometry

GSK-INDI-STD-1

100

square

GSK-INDI-STD-2

300

square

GSK-INDI-STD-3

550-850

square

GSK-INDI-STD-4

1100-1800

square

GSK-INDI-HT-1

100

round

GSK-INDI-HT-2

300

round

GSK-INDI-HT-3

550-850

round

GSK-INDI-HT-4

1100-1800

round

Содержание INDITHERM 100

Страница 1: ...be available at burner inlet throughout the entire capacity range 8 Differential pressure to be measured between burner test connection and combustion chamber 9 Flame lengths are derived from measured...

Страница 2: ...o alter specifications and data without prior notice 2008 Copyright Maxon Corporation All rights reserved 1 2 3 7 E m 7 08 Materials of construction 1 Housing Cast iron 2 Standard sleeve AISI 310 1 48...

Страница 3: ...ilable in ANSI and ISO version Each version will have the main gas inlet connection following either NPT or ISO standards All burners include an adjustable orifice needle valve for pilot flame fine tu...

Страница 4: ...ry block for installation in applications where high temperatures can be expected In following cases the use of high temperature version discharge sleeve is required Dimension A is larger than 50mm In...

Страница 5: ...und the entire discharge sleeve should be present at all times Piloting and ignition INDITHERM burners have an internal pilot burner Piloting is accomplished by internally bypassing the built in gas b...

Страница 6: ...the burner flame Consult MAXON for proper combustion chamber lay out Gas pipe train design The INDITHERM burner is very sensitive to variations in gas pressures at burner gas inlet The burner gas inl...

Страница 7: ...e standard 8 Flame supervision port 9 Spark ignitor Dimensions in mm unless stated otherwise burner size gas inlet 1 A B C D E F G H I J K L M N P S Weight kg 100 1 365 225 200 160 111 442 93 390 431...

Страница 8: ...8 Flame supervision port 9 Spark ignitor Dimensions in mm unless stated otherwise burner size gas inlet 1 A B C D E F G H I J K L M N P S Weight kg 100 1 365 232 200 257 111 442 100 397 438 224 289 35...

Страница 9: ...fice is standard included with the burner and is factory mounted onto the burner pilot gas port In case a burner has been ordered for direct ignition this adjustable orifice is omitted Two available v...

Страница 10: ...gnitor can be mounted directly onto the burner spark ignitor connection port To be used on all burner sizes See table below for mounting position C depending on burner size Filter Elements FLT INDI Re...

Страница 11: ...nting plate of the burner and the duct wall Optionally available in 2 different types GSK INDI STD to be used in combination with standard discharge sleeves square GSK INDI HT to be used in combinatio...

Страница 12: ...have been cured carefully before shipment and shall be kept dry Wetting of the blocks could result in premature failures Handling of INDITHERM burners INDITHERM burners are shipped as complete units...

Страница 13: ...t to alter specifications and data without prior notice 2008 Copyright Maxon Corporation All rights reserved 1 2 3 18 E m 7 08 INDITHERM with standard sleeve INDITHERM with block with seal and support...

Страница 14: ...reserved 1 2 3 19 E m 7 08 Burner mounting flange Refer to below figure to design a correct burner mounting flange on the installation Mounting flange for INDITHERM burners with standard sleeve Dimen...

Страница 15: ...ice 2008 Copyright Maxon Corporation All rights reserved 1 2 3 20 E m 7 08 Mounting flange for INDITHERM burners with high temperature block sleeve Dimensions in mm unless stated otherwise Burner size...

Страница 16: ...art up During and after start up check the integrity of the system Check all bolted connections after first firing first time on tempera ture and retighten if necessary Purge For safety reasons it is...

Страница 17: ...ded preventative maintenance routine Inspect burner internal parts for wear and oxidation paying special attention to the refractory of the burner block when applicable Inspect associated control inst...