Setup
Connections
maxon motor control
3-18
Document ID: rel5543
ESCON Servo Controller
Edition: November 2015
ESCON 70/10 Hardware Reference
© 2015 maxon motor. Subject to change without prior notice.
Figure 3-9
Encoder Input Circuit Ch A “Single-ended” (analogously valid also for Ch B)
Single-ended
Input voltage
0…5 VDC
Max. input voltage
+12 VDC /
−
12 VDC
Logic 0
<1.0 V
Logic 1
>2.4 V
Input high current
I
IH
= typ420
μ
A @ 5 V
Input low current
I
IL
= typically
−
170
μ
A @ 0 V
Max. input frequency
100 kHz