General Safety Information

• To reduce the risk of death, personal injury or property damage from fire, 

electric shock, falling parts, cuts/abrasions, and other hazards read all 
warnings and instructions included with and on the fixture box and all 
fixture labels.

• Before installing, servicing, or performing routine maintenance upon 

this equipment, follow these general precautions.

• Commercial installation, service and maintenance of luminaires 

should be performed by a qualified licensed electrician.

• For Residential installation: If you are unsure about the installation or 

maintenance of the luminaires, consult a qualified licensed electrician 
and check your local electrical code.

• To prevent wiring damage or abrasion, do not expose wiring to edges of sheet 

metal or other sharp objects.

• Do not make or alter any open holes in an enclosure of wiring or electrical 

components during kit installation.

• DO NOT INSTALL DAMAGED PRODUCT!

• Suitable for Dry or Damp location

WARNING:

RISK OF ELECTRICAL SHOCK

• Turn off electrical power at fuse or circuit breaker box before wiring fixture 

to the power supply.

• Turn off the power when you perform any maintenance.

• Verify that supply voltage is correct by comparing it with the luminaire label 

information.

• Make all electrical and grounded connections in accordance with the National Electrical 

Code and any applicable local code requirements.

• All wiring connections should be capped with UL approved wire connectors. 
CAUTION: 

RISK OF INJURY

• Wear gloves and safety glasses at all times when removing luminaire from carton, installing, 

servicing or performing maintenance.

• Avoid direct eye exposure to the light source while it is on.

• Account for small parts and destroy packing material, as these may be hazardous to children.
CAUTION: 

RISK OF FIRE

• Keep combustible and other materials that can burn away from luminaire and lamp/lens.

NOTE: Green ground screw provided in proper location. 

Do not relocate.

NOTE: Minimum 90° supply conductors.

NOTE: Specifications and dimensions subject to change without 

notice.

NOTE: Suitable for Dry or Damp location.

Models:

This instruction manual applies to the LSV Series

Picture is for illustration purposes 
only. Your model may vary.

© Copyright 2021 MaxLite, Inc. All Rights Reserved.
12 York Ave, West Caldwell, NJ 07006   Tel: 800-555-5629   Fax: 973-244-7333   Email: [email protected]

Page: 1
REV: 10/29/21

Included in the box:

• LSV Vapor Tight Fixture
• Instructions
• Brackets (3)
• V-Hooks (3) & hardware

Содержание 105687

Страница 1: ...er supply Turn off the power when you perform any maintenance Verify that supply voltage is correct by comparing it with the luminaire label information Make all electrical and grounded connections in...

Страница 2: ...P switch is accommodated with 3 options left middle and right corresponding to 3 color temperatures and 3 powers respectively which can perform the desired color temperature and lumen output combinati...

Страница 3: ...ion Instructions Operating Instructions LSV Series MaxLite 8ft Vapor Tight LSV Series 1 Locate drill holes for mounting brackets Use hardware found in hardware kit Mount bracket to surface 2 Secure mo...

Страница 4: ...own in figure 6 Connect power supply to the driver through the outlet box as shown in the figure the flexible cord is customer supplied make sure to snap the cover to the outlet box after wiring is co...

Страница 5: ...the junction box and cover the junction box with the UL listed canopy Make sure to provide a strain relief at the canopy side Ensure that the gap is sealed with glue Be sure to provide with a wet loc...

Страница 6: ...ge 6 REV 10 29 21 Chain Suspended Mounting Installation Instructions Continued 3 Hang fixture from customer supplied chain using V brackets 4 Release latches by pulling top of latch away from housing...

Страница 7: ...n Instructions Continued outlet box cover ground wire 7 Connect power supply to the driver through the outlet box as shown in the figure the flexible cord is customer supplied make sure to snap the co...

Страница 8: ...y Pink Red Blue L N LED DIM 12VDC LED light source Green LED _ _ DIM 12VDC Sensor Operating Instructions LSV Series MaxLite 8ft Vapor Tight LSV Series Wiring Diagram Copyright 2021 MaxLite Inc All Rig...

Страница 9: ...LED White _ _ Connector BATTERY LED LED _ _ _ L N AC AC Black Red Connector Black Red EMERGENCY Gray Pink White Red Black 3500K 5000K White Black Black White Brown Purple Brown Purple TEST SWITCH Con...

Страница 10: ...nfo maxlite com Page 10 REV 10 29 21 Emergency Battery Back up Microwave Motion Sensor Additional Accessory LED DRIVER Black White _ _ _ Yellow Brown Purple Gray Pink Red Blue Yellow Purple Gray Pink...

Страница 11: ...tern on the fixture 2 Run the wires from the adapter through the knock out hole of the fixture and attach the adapter using the locking nut Ensure that the adapter is facing downwards after the fixtur...

Страница 12: ...EXPRESS WARRANTY SET FORTH HEREIN IN NO EVENT WILL MAXLITE BE LIABLE FOR ANY SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION DAMAGES RESULTING FROM LOSS OF USE PROFITS BUSINE...

Страница 13: ...ez des travaux d entretien V rifiez si la valeur de la tension d alimentation est correcte en la comparant aux informations dans le tableau sur l tiquette du luminaire R alisez toutes les connexions l...

Страница 14: ...les deux commutateurs DIP Chaque commutateur DIP a 3 options gauche milieu et droite correspondant 3 temp ratures de couleur et 3 niveaux de puissance respectivement qui peut effectuer la combinaison...

Страница 15: ...us de forage pour les supports de montage Utiliser le mat riel trouv dans le kit de mat riel Monter le support sur la surface 2 Fixer les pinces de montage dans les encoches du bo tier en les appuyant...

Страница 16: ...ier de sortie comme illustr dans la figure le cordon flexible est fourni par le client s assurer de remettre le couvercle du bo tier de sortie apr s avoir r alis le c blage 7 Respecter le sch ma g n r...

Страница 17: ...nt aux endroits humides Instructions d installation suspendue par cha nes 1 Attacher le support en V chaque pince de montage en cartant les bouts du support en V et en ins rant ensuite les jambes dans...

Страница 18: ...eau LED du luminaire 6 Localiser le c ble de s curit lors de l ouverture pour installer le corps du luminaire et connecter le c ble au plateau du mat riel avant d effectuer les connexions lectriques c...

Страница 19: ...lage 8 Respecter le sch ma g n ral de c blage ci dessus pour r f rence S assurer que l alimentation lectrique est d connect e avant l installation 9 Rattacher le plateau LED au luminaire en suivant l...

Страница 20: ...ris Rose Rouge Bleu L N LED VAR 12VCC Source de lumi re LED Vert LED _ _ VAR 12VCC Capteur Sch ma de c blage Mode d emploi S rie LSV MaxLite de 244cm 8 pi tanche la vapeur S rie LSV Droits d auteur 20...

Страница 21: ...nc _ _ Connecteur BATTERIE LED LED _ _ _ L N CA CA Noir Rouge Connecteur Noir Noir Rouge Rouge URGENCE Gris Rose Blanc 3500K 5000K Blanc Noir Noir Blanc Marron Violet Marron Violet COMMUTATEUR DE TEST...

Страница 22: ...axlite com Page 10 REV 10 29 21 Batterie de secours et Capteur de mouvement micro ondes accessoire suppl mentaire PILOTE LED Noir Blanc _ _ _ Jaune Marron Violet Gris Rose Rouge Bleu Jaune Violet Gris...

Страница 23: ...e luminaire 2 Faites passer les fils de l adaptateur travers le trou d foncer du luminaire et fixez l adaptateur l aide de l crou de blocage Assurez vous que l adaptateur est orient vers le bas apr s...

Страница 24: ...EXPRESSE D FINIE DANS LES PR SENTES MAXLITE NE SERA EN AUCUN CAS RESPONSABLE DES DOMMAGES PARTICULIERS ACCESSOIRES OU CONS CUTIFS Y COMPRIS SANS S Y LIMITER LES DOMMAGES R SULTANT DE LA PERTE D UTILI...

Отзывы: