background image

OUT-LOOK 

Outdoor/indoor intrusion detector 

Preliminary Quick Reference 

Ver.1      28/05/2008 

 

Page 

 (of 6) 

 

 

ON

 

LEDs

OFF 

After 15 

minutes

#4

.

#5

.

Detection 

Range Setting

Auto Night 

Detection mode

DIP SWITCH SETTING

 

#2

.

Pulse Count

4

2

Low

High

Anti-masking 

Sensitivity and 

Learning, 

 

and Detection 

Technology 

Combination

OR

AND

#3

.

Physical

setting, 

by 

Trimmers

Setting 

by "Walk 

Test"

Low

High

Microwave and PIR sensitivity 

adjustment

 

High

Microwave

 

Sensitivity 

Adjustment

 

PIR

 

Sensitivity 

Adjustment

 

High

ON

OFF 

DIP Switch Specifications 

 

DIP Switch 

#1

,

 LED indication:

 ON or OFF (when switching to OFF, the LED indication will be           

                                                         enabled for 15 minutes- in order to allow "walk test". 

DIP Switch 

#2

,

 Pulse Count:

 Select between 2 or 4 pulses. 

                                                     Choose 2 pulses in a place with a low risk to false alarm. 

                                                     Choose 4 pulses in a place with a high risk to false alarm. 

DIP Switch 

#3

,

 Anti-masking Sensitivity and Learning, and Detection Technology Combination:

  

a.

 Select between LOW and HIGH Anti-masking Sensitivity. 

   Choose 

LOW

 Anti-masking Sensitivity in a place suffering of dust. 

   Choose 

HIGH

 Anti-masking Sensitivity in a place that doesn't suffering of dust. 

b.

 

Learning

: Once the state of the DIP switch is changed, OUT-LOOK learns the environmental conditions 

of its protected area (refer to page No.

6

). 

c.

 Select 

AND

 if you wish a true alarm will be generated just when the intrusion is detected by both 

detection technologies (PIR 

AND

 Microwave). 

Select 

OR

 if you wish a true alarm will be generated when the intrusion is detected by one of two detection 

technologies (PIR 

OR

 Microwave). 

Remark: the detection technology combination 

OR

 is valid just when OUT-LOOK detected that its near 

field-of-view is masked/covered (Anti-masking). Otherwise, the detection technology combination is 

AND