PREPARING THE MASKING CHANNEL FOR OPERATION
(Obligatory for
proper Anti-masking operation!!!)
To enable proper operation of the masking detection
(Anti-masking)
, it is necessary to allow the
detector to automatically study and analyze the environmental conditions of its protected area.
This is an obligatory action that should be performed by the installer, ensuring proper operation of
the Anti-masking channel
!!!
Study procedure to be performed in two cases:
1. Upon connecting the power supply to the detector (after about 1 minute, the time it takes the
detector to stabilize when first fed by power supply).
2. Upon the position of DIP switch number-3 (LED indicator) is changed.
Study procedure:
- Immediately close the detector’s case (within 30 seconds maximum).
- Keep at least 1 meter away from its front part, until the study procedure is complete, about 2
minutes.
PERFORM A TEST
* To be carried out when the case is closed and the LED indicators are enabled
(DIP switch No.1 switched to ON).
Test procedure for human movement detection (Alarm):
o
Walk in the protected area.
o
Compulsory reaction of the detector:
Upon each detection, the “Alarm Relay” will operate for 2 seconds.
The Red+Yellow LED indicators will flash simultaneously during those 2 seconds.
Test procedure for masking detection (Anti-masking):
o
At a distance of about 10 cm from the front of the detector, place a white piece of paper (or any
other object).
o
Compulsory reaction of the detector:
The Green LED will immediately flash continuously as long as the masking object exists.
If the masking object exists for more than 40 seconds, the Green LED will glow continuously
and the "MASK”
(Anti-masking)
relay will operate for at least 2 seconds and for as long as
masking exists.