OUT-LOOK
Outdoor/indoor intrusion detector
Preliminary Quick Reference
Ver.1 28/05/2008
Page
3
(of 6)
DIP Switch
#4
,
Detection Range Setting.
There are two ways to set the detection range:
a.
Physical setting by the Trimmers
, allows you to set the detection range manually- by the described
above PIR and Microwave Trimmers.
b.
Setting by a "Walk Test"
, allows you to set the detection range automatically- by moving in the
protected area ("Walk test"). Valid just if the required detection range is above 3 meters.
The adjustment of the PIR and Microwave Trimmers must be carried out before the
Setting by a "Walk
Test"
.
Here is who to set the detection range automatically, by a "Walk Test":
1. Once you move DIP switch No. 4 from OFF to ON position, the
Red
,
Green
and
Orange
will glow.
2. Close the detector's case immediately and go to the most distant point of the desired detection range (Not
over the detector's maximum detection range limitations!) and wait there, for a few seconds, until the
Green
LED will glow alone.
3. Once the
Green
LED glows (alone), you should define the detection range borders by walking parallel to
the detector's front to the most distant points of the desired detection range, while obey these easy
instructions provided by detector's LED indicators:
Green
Walk
!
Red
Stop!
That "Walk/Stop" procedure will repeat 4 times.
5. As an indication for the end of procedure, the
Green
and
Red
LED indicators will glow for 8 seconds.
DIP Switch
#5
,
Auto Night Detection Mode
.
Set to
"ON"
if you wish during night (darkness) the detection range will be automatically shifted to a
different detection range.
If DIP switch No. 4 is set to
Setting by "Walk Test"
position,
Then:
- During the day (light) the detection range is as defined in the "Walk Test".
- Once the night (darkness) comes, the detection range defined by the PIR and Microwave Trimmers.