ul 325 compliant

installation requirements

A

  Install the gate operator only when:

   

1

  The operator is appropriate for the construction of the gate and the usage Class of the gate,

   

2

  All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 6 feet (1.83 m) above the 

   

  ground to prevent a 2-1/4 inch (57.2 mm) diameter sphere from passing through the openings anywhere in the gate, and in that 

   

  portion of the adjacent fence that the gate covers in the open position,

   

3

  All exposed pinch points are eliminated or guarded, and

   

4

  Guarding is supplied for exposed rollers.

B

  The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate access opening. The 

  pedestrian access opening shall be designed to promote pedestrian usage. Locate the gate such that persons will not come in contact with 
  the vehicular gate during the entire path of travel of the vehicular gate.

C

  The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and 

  closing to reduce the risk of entrapment. Swinging gates shall not open into public access areas.

D

  The gate must be properly installed and work freely in both directions prior to the installation of the gate operator. Do not over-tighten the 

  operator clutch or pressure relief valve to compensate for a damaged gate.

E

  For gate operators utilizing Type D protection:

   

1

  The gate operator controls must be placed so that the user has full view of the gate area when the gate is moving,

   

A gate operator shall additionally be provided with a placard that is marked in letters at least 1/4-in (6.4-mm) high with the word 

   

  “

WARNING

” and the following statement or the equivalent: 

“Moving Gate Has Potential of Inflicting Injury or Death - Do Not Start 

   

  Gate Unless Path is Clear”

.

   

3

  An automatic closing device (such as a timer, loop sensor, or similar device) shall not be employed, and

   

4

  No other activation device shall be connected.

F

  Controls intended for user activation must be located at least six feet (6’) away from any moving part of the gate and where the user is 

  prevented from reaching over, under, around or through the gate to operate the controls. Outdoor or easily accessible controls shall have a 
  security feature to prevent unauthorized use.

G

  The Stop and/or Reset button must be located in the line-of-sight of the gate. Activation of the reset control shall not cause the operator to start.

H

  A minimum of two (2) WARNING SIGNS shall be installed, one on each side of the gate where easily visible.

I

  For gate operators utilizing a non-contact sensor:

   

1

  See instructions on the placement of non-contact sensors for each Type of application,

   

2

  Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle, trips the sensor while the gate is still moving, and

   

3

  One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the perimeter reachable 

   

  by a moving gate or barrier.

J

  For a gate operator utilizing a contact sensor:

   

1

  One or more contact sensors shall be located where the risk of entrapment or obstruction exists, such as at the leading edge, trailing 

   

  edge, and post mounted both inside and outside of a vehicular horizontal slide gate.

   

2

  One or more contact sensors shall be located at the bottom edge of a vehicular vertical lift gate.

   

3

  One or more contact sensors shall be located at the pinch point of a vehicular vertical pivot gate.

   

4

  A hardwired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate 

   

  operator is not subjected to mechanical damage.

   

5

  A wireless device such as one that transmits radio frequency (RF) signals to the gate operator for entrapment protection functions 

   

  shall be located where the transmission of the signals are not obstructed or impeded by building structures natural landscaping or 

   

  similar obstruction. A wireless device shall function under the intended end-use conditions.

   

6

  One or more contact sensors shall be located on the inside and outside leading edge of a swing gate. Additionally, if the bottom edge 

   

  of a swing gate is greater than 6 inches (152 mm) above the ground at any point in its arc of travel, one or more contact sensors shall 

   

  be located on the bottom edge.

   

7

  One or more contact sensors shall be located at the bottom edge of a vertical barrier (arm).

Содержание Max Megatron 1400

Страница 1: ...rushless DC Swing Gate Operators Made in USA CONFORMS TO UL STD 325 UL CLASS I II III IV CERTIFIED TO CAN CSA STD C22 2 NO 247 Bi Parting Gates ONLY Single or Bi Parting Gates Single or Bi Parting Gat...

Страница 2: ......

Страница 3: ...Overview Primary Gate Open Left Open Right Close Timer Selectable Gate Speed Control Battery Back Up Mode Anti Tailgate Single Pass Anti Tailgate Radio Receiver Radio Safety Pause Gate in Motion Alarm...

Страница 4: ...1600lbs 12 ft gate per operator 90 Opening Time MAX Megatron 1400 1400HP 2200 16 selectable speeds from approximately 11 5 sec to 20 sec depending on the weight and length of the gate MAX Megatron FAS...

Страница 5: ...rsonnel SECURITY AUTHORIZED PERSONNEL ONLY ul 325 model classifications A Inherent entrapment protection system B1 Provision for connection of a non contact sensor photoelectric sensor or the equivale...

Страница 6: ...art of the gate and where the user is prevented from reaching over under around or through the gate to operate the controls Outdoor or easily accessible controls shall have a security feature to preve...

Страница 7: ...t the gate operator from accidentally closing on vehicles in the gate s closing path and entrapment M ovin g Gate Can Cause Serious In ju ry or Death KE EP CL EA R Ga te may mov e at an y tim e withou...

Страница 8: ...mper NO COM GND T amper IN OFF OFF ON EXIT P ARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH CLAMP SLIPPING MIN MAX 12VDC GND 24VDC GND MAX MIN OF...

Страница 9: ...ION CENT ER REVE RSE SENS ITIVIT Y MOTO R OVER LOAD NO LIMIT SWIT CH CLAM P SLIPP ING MIN MAX 12VD C GND 24VD C GND MAX MIN OFF SAFET Y LEAVE OPEN LEAVE CLOS ED MADE in USA OPEN 1 TIME 2Sec 1 5Se c C...

Страница 10: ...should be installed at the gate bracket height across the ENTIRE gate to keep the gate pickets from bending YES YES NO NO Gate Bracket Support Bar Too High Not Long Enough Support Bar MOTOR Power In...

Страница 11: ...D MAX MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1 5Sec COM NC BATTERY IN USE POWER GATE STATUS MOTOR ON LINE LIMIT SWITCH ON LINE GND PRIMARY GATE GND SEC GATE UL ENTRAP PHOT...

Страница 12: ...com Made in USA BATTERY PACK TO MOTOR CONTROLLER PhotoCell Edge UL Entrap 1 2 Limit SW ON LINE MATRIX JOG LEFT JOG RIGHT Jog LT Jog RT GND Edge 1 Edge 2 Photo Cell ERD Motor OverLoad POWER MC 200 Moto...

Страница 13: ...tely install a Remote MAX Megatron Toroid box Install the MAX Magic Box near the 115 VAC or 230 VAC input AC power source up to 1000 ft away from gate operator NOTE A MAX Magic Box kit is required for...

Страница 14: ...IMIT 2 4 V GND UL ALARM 12V ALARM RET RESET GND GA TE T AMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELA Y PRIMARY GA TE SAFETY CENTER EXIT OPEN MAX GA TE SPEED STOP CLOSE ANTI T AILGA TE CLOSE TIMER...

Страница 15: ...onitored Normally Closed Type IMPORTANT Sensing edges MUST be Monitored 10K Normally Closed Type and a GEM 104 module MUST be installed Closed Gate Max 10K Mini Sensing Edge N C Hinge Area End of Gate...

Страница 16: ...ired in series MOTOR ON LINE LIMIT SWITCH ON LINE 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED S...

Страница 17: ...FETY CENT ER EXIT OP EN MAX GA TE SP EED STOP CLOS E AN TI TAILGA TE CLOS E TIMER PO SITION RE CO RD ER ID PLUG AUTOMATIC OPEN CLOSE CONTROLS BATTER Y BA CK UP MOD E MATRIX 1 PH OT OC ELL ED GE 1 ED...

Страница 18: ...Battery Button Press to show amount of battery power available when using battery power ONLY Battery voltage LEDs will light respectively Battery IN Error LED Lights when there is a battery connectio...

Страница 19: ...t End of Gate Options GND C P h o to C e ll E d g e U L E n tr a p 1 2 L im it S W O N L IN E M A T R IX J O G L E F T J O G R I G H T J o g L T J o g R T G N D E d g e 1 E d g e 2 P h o to C e ll E R...

Страница 20: ...AD RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG RADIO GND OPEN STOP CLOSE COM GATE DISABLE E TIMER CENTER MAX MIN OFF SAFETY POSITION CORDER OPEN STOP CLOSE MOTOR MOTION Inputs MUST be LEARNED to MONI...

Страница 21: ...rotec tio n co ntre les ris qu es d ince nd ie utilise r un fusible de m m es type et ca ract ristiq ue s no minales AC IN Power LED M A X M e g a t r o n T o r o i d B o x disconnect power before ser...

Страница 22: ...Polarity Matters Remove the Remote Toroid 15 Amp connector from the BC 7 battery module POWER SOLAR IN port Plug the Magic Box POWER SOLAR IN connector into the POWER SOLAR IN port NOTE A MAX Magic Bo...

Страница 23: ...e BATTERY IN POWER SOLAR IN POWER IN Battery Pack TO MOTOR CONTROLLER w w w M a x U S c o m BATTERY IN POWER SOLAR IN Refer to Solar application guide Max Solar Power Kit Sold separately Connect to PO...

Страница 24: ...ge Re pla ce Ba tte ry TE ST Ba tte ry Ba tte ry IN Err or MAX BC 7 Ba tte ry Mo du le B A T T E R Y IN P O W E R S O L A R IN P O W E R IN B a tt e ry P a c k T O M O T O R C O N T R O L L E R w w w...

Страница 25: ...t 2 or 3 3 Press an d HOLD the OPEN STO P bu tto ns at the sa me tim e on Matrix 1 un til be ep is he ard learn mod e be gins Le arn mod e lasts for 5 min indica ted by be ep ing 4 LE Ds WILL be ON f...

Страница 26: ...le attempts to tailgate The second vehicle must then back off the safety loop for the gate to continue closing A new radio signal will open the gate When turned ON a moving gate will pause if a radio...

Страница 27: ...Dual Gates See page 34 See page 28 Emergency OPEN Overrides gate disable switch MAX OPEN Overrides gate disable switch 4 Wire Radio 3 Wire Radio Emergency Security Devices Normal Opening Devices Norm...

Страница 28: ...rements for each successive click up to 60 sec MAX NOTE 1 2 sec MIN position is recommended for High Traffic areas gate close timer MOTOR ON LINE LIMIT SWITCH ON LINE 24V GND UL ALARM 12V ALARM RET RE...

Страница 29: ...L GND STRIKE GND KEYPAD RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG RADIO GND OPEN STOP CLOSE COM GATE DISABLE MOTOR ON LINE LIMIT SWITCH ON LINE SAFETY ANTI TAILGATE OFF ON AUTHORIZED Vehicle UNAUTH...

Страница 30: ...BATTERY IN USE POWER GATE STATUS GND PRIMARY GATE GND SEC GATE UL ENTRAP PHOTOCELL GND STRIKE GND KEYPAD RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG RADIO GND OPEN STOP CLOSE COM GATE DISABLE ID PLU...

Страница 31: ...when there is an error with the corresponding loop detector NOTE Reno H2 detector always blinks steadily during normal operation MOTOR ON LINE LIMIT SWITCH ON LINE 24V GND UL ALARM 12V ALARM RET RESE...

Страница 32: ...MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH CLAMP SLIPPING MIN MAX 12VDC GND 24VDC GND MAX MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1 5Sec COM NC BATTER...

Страница 33: ...FF OFF ON EXIT PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH CLAMP SLIPPING MAX 12VDC GND 24VDC GND MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE...

Страница 34: ...TATUS GATE OPEN GATE CLOSED OPEN STOP STOP CLOSE Com Power GND GND N O Com MOTOR ON LINE LIMIT SWITCH ON LINE 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK...

Страница 35: ...MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON EXIT PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMI...

Страница 36: ...ONITO R se ns ors To LE AR N inpu ts 1 MONITO RE D Se ns ors MUS T be wired to inpu ts BE FO RE they ca n be learne d An y un us ed inpu ts MUS T be jumpe red 2 Re ve rsing Ed ge an d or Ph oto Ce ll...

Страница 37: ...the button to stop gate This allows gate to be moved back and fourth without leaving the operator to fine tune the open and close gate positions if desired Adjustments open and close limits CLOSED LI...

Страница 38: ...eadjustment is necessary After Release Handle Clamp is in the SECURE HORIZONTAL position Pull the arm NO slippage should occur If it does readjust Adjustment Bolt factory set bolt DO NOT adjust adjust...

Страница 39: ...tes LED is off B Turn knob counter clockwise to reduce sensitivity during ERD testing as needed LED remains OFF for all but position 1 IMPORTANT When satisfied with ERD adjustment cycle the gate 3 or...

Страница 40: ...home owner must call a qualified professional gate operator technician for any repairs and modifications The gate operator is virtually maintenance free to an end user home owner minimal maintenance i...

Страница 41: ...NC BATTERY IN USE POWER GATE STATUS MOTOR ON LINE LIMIT SWITCH ON LINE GND PRIMARY GATE GND SEC GATE UL ENTRAP PHOTOCELL GND STRIKE GND KEYPAD RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG RADIO GND OP...

Страница 42: ...nics Box MAX BC 7 Battery Module BATTERY IN POWER SOLAR IN POWER IN Battery Pack TO MOTOR CONTROLLER www Max US com CLOSED LIMIT OPEN LIMIT To SEC GATE input on Matrix 1 Motor MAX Megatron Toroid Box...

Страница 43: ...hood and remove it 2 Make sure ALL power is OFF to operator 1 Pull red handle up and move gate 3 maintenance manual gate release Arm WARNING WARNING NEVER grasp the arm to move gate Pinch Point Arm AL...

Страница 44: ...econd obstruction occurred CHECK THE GATE AREA FOR ANY PROBLEMS BEFORE pressing the STOP button on the Matrix 1 or the externally mounted Alarm Reset button to shut off the alarm and reset the gate NO...

Страница 45: ...HO TOC ELL EDG E 1 EDG E 2 ID PLU G ERR OR OPE N COM CLO SE Tam per NO COM GND Tam per IN OFF OFF ON EXIT PAR TIAL OPE N OBD POR T BLA CK BOX MO TOR MO TIO N CENT ER REVE RSE SENS ITIVI TY MOT OR OVER...

Страница 46: ...e without an RMA number Shipping charges to and from the factory service center for warranty repairs are the responsibility of the customer Repair or replacement of any warranty items is made at the s...

Страница 47: ...te the relay when a number of security circumstances occur making illegal entry almost impossible when the gate operator is connected to a existing building home alarm system The GATE TAMPER relay wil...

Страница 48: ...O PRI_MC Fully Open Posi on Learned Fri 07 11 2014 10 58 53 INFO SEC_MC Fully Open Posi on Learned Fri 07 11 2014 10 57 40 INFO PRI_CIO Communica on Established Fri 07 11 2014 10 57 38 ENTRAP PRI_MC P...

Страница 49: ...47...

Страница 50: ...48...

Страница 51: ...49...

Страница 52: ...99 0220 www max us com 4009963 CONFORMS TO UL STD 325 UL CLASS I II III IV CERTIFIED TO CAN CSA STD C22 2 NO 247 Residential Commercial Brushless DC Swing Gate Operators Made in USA 14 0 0 H P 14 0 0...

Отзывы: