22
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETY
CENTER
EXIT
OPEN
MAX
GATE SPEED
STOP
CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFF
ON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec
1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
MOTOR
ON-LINE
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
FIRE DEPT
GND
RADIO SIG.
RADIO GND
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
Secondary
Gate Operator
(
NO
Matrix 1)
Primary
Gate Operator
Matrix 1
FU
SE
7 Am
p
PO
W
ER
11
5V
AC
3A
ma
x
On
Of
f
WA
RNI
NG:
Fo
r cont
inu
ed
pr
otec
tio
n
ag
ains
t fi
re,
re
pla
ce
onl
y w
ith t
he
sa
me
typ
e a
nd r
ati
ng
of
fuse.
AV
ER
TIS
SE
ME
NT
:
pou
r n
e p
as
co
mpr
om
ett
re
la
prote
cti
on co
ntr
e l
es
risq
ue
s d
’incen
die,
uti
lise
r un
fusi
ble
de
m
êm
es
typ
e et
ca
rac
tér
ist
ique
s
nom
inal
es
.
ON/OFF
Batte
ry
E
F
1/2
Battery
Voltage
Re
plac
e
Batte
ry
TE
ST
Battery
Battery
IN
Erro
r
MAX
BC-
7
Bat
tery
Modu
le
BAT
TER
Y
IN
PO
W
ER/
SO
LAR
IN
PO
W
ER
IN
Batte
ry
Pack
TO
M
OTO
R
CO
NT
RO
LLE
R
www
.Max
.U
S.c
om
To MC
Batte
ry Pac
k
To MC
POWER
IN
Ph
oto
Ce
ll
Edg
e
UL
Entr
ap
1
2
Lim
it SW
ON
-LIN
E
MAT
RIX
JO
G
LE
FT
JO
G
RIGH
T
Jo
g LT
Jo
g R
T
GN
D
Ed
ge
1
Ed
ge
2
Photo
Ce
ll
ER
D
Mo
tor
Ov
erL
oad
POW
ER
MC
-20
0
Mo
tor
Con
trolle
r
16
15
14
13
12
3
4
5
MA
X
LE
D O
N
Ed
ge
Sen
sitivi
ty
ER
D
MOT
OR
Powe
r In
PWR 24V -
GND -
RS-485 (-) -
RS-485 (+) -
not used -
not used -
GND -
PWR 12V -
MA
TR
IX
BOAR
D
AL
ARM
BAT
TE
RY
PA
CK
LIM
IT
SW
ITC
H
MO
TO
R
INPUT
S
MA
X MC
-200
Primary
Secondary
3 Wires to Matrix 1
NO
24V
to
Matrix 1
Connect (3) three RS-485 wires from the
SECONDARY operator’s
MAX MC-200 motor
controller
to the
Matrix 1 - SEC GATE.
•
Pos (+) to Pos (+)
•
Neg (-) to Neg (-)
•
Gnd to Gnd
•
DO NOT
connect
PWR 24V.
Wiring operator
secondary operator to matrix 1
22 AWG Min. 3-conductor
twisted pair, shielded cable
MOTOR
Power In
PWR 24V -
GND -
RS-485 (-) -
RS-485 (+) -
not used -
not used -
GND -
PWR 12V -
MATRIX
BOARD
ALARM
BATTER
Y
PAC
K
LIMIT
SWITCH
MOTO
R
INPUTS
Secondary
Operator
MAX MC-200
4-Pin Plug
4-Pin Plug
Unplug 4-Pin plug from the bottom of the
MAX MC-200 motor controller
and connect
RS-485 wires as shown below.
NOTE:
The Alarm Shut-Off is
located on the Primary gate
operator
ONLY
. There is
NO
alarm shut-off button on the
secondary gate operator.
3 Wires to Matrix 1