background image

29

MOTOR

ON-LINE

LIMIT

SWITCH

ON-LINE

24V

GND

UL ALARM 12V

ALARM RET

RESET

GND

GATE

TAMPER

MAG

LOCK

OPEN

RIGHT

OPEN

LEFT

MAGLOCK

DELAY

PRIMARY

GATE

SAFETY

CENTER

EXIT

OPEN

MAX

GATE SPEED

STOP

CLOSE

ANTI

TAILGATE

CLOSE TIMER

POSITION

RECORDER

ID

PLUG

AUTOMATIC OPEN/CLOSE CONTROLS

BATTERY

BACK-UP MODE

MATRIX 1

PHOTOCELL

EDGE 1

EDGE 2

ID PLUG

ERROR

OPEN

COM

CLOSE

Tamper NO

COM
GND

Tamper IN

OFF

OFF

ON

EXIT

PARTIAL

OPEN

OBD PORT

BLACK BOX

MOTOR MOTION

CENTER

REVERSE SENSITIVITY

MOTOR OVERLOAD

NO LIMIT SWITCH /

CLAMP SLIPPING

MIN

MAX

12VDC

GND

24VDC

GND

MAX

MIN

OFF

SAFETY

LEAVE

OPEN

LEAVE

CLOSED

MADE in USA

OPEN
1 TIME

2Sec

1.5Sec

COM

NC

BATTERY

IN USE

POWER

GATE

STATUS

(+)

GND

(-)

PRIMARY

GATE

(+)

GND

(-)

SEC

GATE

 UL

ENTRAP

PHOTOCELL

GND

STRIKE

GND

KEYP

AD / RDR

GND

FIRE DEPT

GND

MAX OPEN

GND

RADIO SIG.

RADIO GND

OPEN

STOP

CLOSE

COM

GA

TE DISABLE

PRIMARY

BATTERY

1

CLOSE TIMER

MAX

MIN

PHOT

OFF

SAFETY

matrix 1

Matrix 1 will accept third party loop detectors in the 3 ports. Each loop detector has a 
corresponding in-ground loop that must be connected for the loop system to operate 
(see below). Power down Matrix 1 

BEFORE

 connecting loop detectors. Refer to your 

chosen loop detector’s instruction sheet for specific information about loop detector.

Loop Detectors

maglock

Maglock 

MUST

 be connected as shown.

MAGLOCK DELAY:

 You 

MUST

 select a time 

delay when using a maglock.
Maglock power disengages 1.5 sec 

or

2 sec 

before

 gate starts opening.

MAGLOCK LED (Monitors Maglock):
ON

 - Locked      

OFF

 - Unlocked

Flashing

 - Problem with Maglock Power.

MOTOR

ON-LINE

LIMIT

SWITCH

ON-LINE

24V

GND

UL ALARM 12V

ALARM RET

RESET

GND

GATE

TAMPER

MAG

LOCK

OPEN

RIGHT

OPEN

LEFT

MAGLOCK

DELAY

PRIMARY

GATE

SAFETY

CENTER

EXIT

OPEN

MAX

GATE SPEED

STOP

CLOSE

ANTI

TAILGATE

CLOSE TIMER

ID

PLUG

AUTOMATIC OPEN/CLOSE CONTROLS

BATTERY

BACK-UP MODE

MATRIX 1

PHOTOCELL

EDGE 1

EDGE 2

ID PLUG

ERROR

OPEN

COM

CLOSE

Tamper NO

COM
GND

Tamper IN

OFF

OFF

ON

EXIT

MOTOR MOTION

CENTER

REVERSE SENSITIVITY

MOTOR OVERLOAD

NO LIMIT SWITCH /

CLAMP SLIPPING

MIN

MAX

MAX

MIN

OFF

SAFETY

LEAVE

OPEN

LEAVE

CLOSED

MADE in USA

OPEN
1 TIME

2Sec

1.5Sec

COM

NC

BATTERY

IN USE

POWER

GATE

STATUS

(+)

GND

(-)

PRIMARY

GATE

(+)

GND

(-)

SEC

GATE

 UL

ENTRAP

PHOTOCELL

GND

STRIKE

GND

KEYP

AD / RDR

GND

FIRE DEPT

GND

MAX OPEN

GND

RADIO SIG.

RADIO GND

OPEN

STOP

CLOSE

COM

GA

TE DISABLE

OPEN

MAX

GATE SPE

STOP

MOTOR MOTION

MIN

M

EPT

RADIO SIG.

DIO GND

CENTER

EXIT

ANTI

TAILGATE

UTOMATIC OPEN/CLOSE CONTROLS

OFF

ON

EXIT

CENTER

Reno

Loop Detector

(Plug-In)

LED always

blinks steadily

during

operation

Connect desired loop detector
to appropriate loop port

Maglock
Power

Pos

Neg

Pos

Neg

Maglock

SAFETY

CENTER

EXIT

OPEN/CLOSE CONTROLS

ON

1

2

3

4

5

6

7

8

5 = Opt

im

um

 Sens.

   = I

ncre

ase

 Sen

s.

   =

 Dec

reas

e Se

ns

.

DEFLEC

TOMETER

PO

WE

R

ON 

 = No

rm

al P

ow

er

OF

F= No

 Pow

er

LED 

INDI

CAT

ORS

DETEC

T

ON 

 = De

tec

t

OF

F= No

 Det

ect

2 Hz 

Flash

=Del

ay Ti

ming

SW1 

SW2   Frequ

enc

y

ON 

ON

   = L

ow

ON 

OF

F  =

 Me

dium

-Low

OF

ON 

  = 

Med

ium

-Hi

gh

OF

OF

F  = 

Hig

h

SW4 

SW5   Output 

B

ON 

ON

   = Pu

lse o

n En

try

ON 

OF

F  = 

B sa

me 

as A

OFF 

ON 

  = Pu

lse o

n Exi

t

OFF 

OF

F  

= Lo

op 

Fau

lt

SW3
ON

    =

 Fai

l Secure

OF

F  =

  Fa

il S

afe

SW

6

ON 

   = 2

 Sec

on

d De

lay

OF

F  =

  No

 Del

ay

SW7
ON    

= No

rm

al P

resence

OFF 

 =  In

fin

ite Pre

se

nc

e

SW

8

ON 

   = S

ens

itivity

 Boo

st

OF

F  = 

 No

 Se

nsiti

vity

 Boo

st

Loop

 Faul

t

1 Flash 

 = O

pen 

Loop

2 Fla

shes

= Sh

orted

 Loo

p

3 Fl

ashe

s=25%

 cha

nge

 

    of 

Induc

tance

Bot

h LED’

s Fla

shin

g=

   Cur

rent 

Loop 

Faul

t

PWR

 LED 

Flas

hing=

   Pre

vious

 Lo

op Fa

ult

EDI

Tel: 

480.968.6407

DEF

LE

CT

OM

ET

ER

SEN

S

RE

SE

T

POW

ER

DE

TECT

ED

I

SENS

LM

A1

800

OPTIONS

1

2

3

4

5

6

7

8

ON

In-ground loop connection

Connect each in-ground loop wires to the appropriate input. Lead wires 
should be twisted together 6 twists per foot 
minimum.
See page 14 for in-ground loop installation.

Safety loop wires must be wired in series.

Each LED will light when the corresponding 
loop detector get activated by a vehicle 
passing over its in-ground loop.
LEDs will flash when 
there is an error with the 
corresponding loop 
detector.

NOTE:

 Reno H2 detector 

always blinks steadily 
during normal operation.

MOTOR

ON-LINE

LIMIT

SWITCH

ON-LINE

24V

GND

UL ALARM 12V

ALARM RET

RESET

GND

GATE

TAMPER

MAG

LOCK

OPEN

RIGHT

OPEN

LEFT

MAGLOCK

DELAY

PRIMARY

GATE

SAFETY

CENTER

EXIT

OPEN

MAX

GATE SPEED

STOP

CLOSE

ANTI

TAILGATE

CLOSE TIMER

POSITION

RECORDER

ID

PLUG

AUTOMATIC OPEN/CLOSE CONTROLS

BATTERY

BACK-UP MODE

MATRIX 1

PHOTOCELL

EDGE 1

EDGE 2

ID PLUG

ERROR

OPEN

COM

CLOSE

Tamper NO

COM
GND

Tamper IN

OFF

OFF

ON

EXIT

PARTIAL

OPEN

OBD PORT

BLACK BOX

MOTOR MOTION

CENTER

REVERSE SENSITIVITY

MOTOR OVERLOAD

NO LIMIT SWITCH /

CLAMP SLIPPING

MIN

MAX

12VDC

GND

24VDC

GND

MAX

MIN

OFF

SAFETY

LEAVE

OPEN

LEAVE

CLOSED

MADE in USA

OPEN
1 TIME

2Sec

1.5Sec

COM

NC

BATTERY

IN USE

POWER

GATE

STATUS

(+)

GND

(-)

PRIMARY

GATE

(+)

GND

(-)

SEC

GATE

 UL

ENTRAP

PHOTOCELL

GND

STRIKE

GND

KEYP

AD / RDR

GND

FIRE DEPT

GND

MAX OPEN

GND

RADIO SIG.

RADIO GND

OPEN

STOP

CLOSE

COM

GA

TE DISABLE

T

Removable Terminal

Lead
Wires

SAFETY LOOP

SAFETY LOOP

EXIT LOOP

CENTER LOOP

Outside Property

Inside Property

EXIT

CENTER

SAFETY

12345

6

7

8

ON

EX

T=

SW

 8

SW 7

OFF

OF

F

ON

OFF

ON
ON

OF

F

ON

0 S

EC

SE

C

5 SE

C

10

 SE

C

DL

Y=

SW

 6

SW 5

OF

F

OFF

ON

OFF

ON

ON

OF

F

ON

0 S

EC

SE

C

5 SE

C

10

 SE

C

FREQ

=

SW

 2

SW

 1

ON

ON

OFF
ON

OF

F

OF

F

ON
OF

F

LO

W

NO

RM

M

ED

HI

GH

BO

OST

SW 4

OF

F

ON

ON

OF

F

M

ODE

SW 3

OF

F

ON

FAIL

 SECUR

E

FA

IL SAF

E

VE

HICL

E DETECTOR

MODEL H2

8-

30 VD

C

LO

W

NO

RM

HIG

H

0
3
7

SE

NSITI

VIT

Y

RENO

RENO

A&E

POWE

R

DE

TECT

FA

IL

EDI

Loop Detector

(Plug-In)

EDI

Loop Detector

Low Current

Draw

(Plug-In)

ON

1

2

3

4

5

6

7

8

5 = 

Opti

mum 

Sens.

   = 

Incr

ease Sens

.

   = 

Decrea

se Sens

.

DEFLECTOME

TER

PO

WER

ON  

= Normal 

Po

wer

OFF= No

 Power

LED IN

DICA

TORS

DETECT
ON  

= Detect

OFF= No

 Detect

2 Hz Fl

ash=Delay 

Tim

ing

SW1 

SW2   Frequenc

y

ON 

ON

   = 

Low

ON 

OF

F  

= Me

diu

m-L

ow

OFF 

ON

   = 

Med

ium-H

igh

OFF 

OFF  

= Hi

gh

SW4 

SW5   Output 

B

ON 

ON

   = 

Pulse

 on 

Ent

ry

ON 

OFF  

= B sa

me as 

A

OFF 

ON

   = 

Puls

e on 

Exit

OFF 

OFF  

= Loo

p Fault

SW3

ON   

 = Fai

l Secu

re

OFF 

 =  Fa

il Sa

fe

SW6

ON   

 = 2 Secon

d De

lay

OFF 

 =  No

 De

lay

SW7

ON   

 = No

rmal

 Pre

senc

e

OFF 

 =  

Infi

nite 

Pres

enc

e

SW8

ON   

 = S

ens

itiv

ity Bo

os

t

OFF 

 =  No

 Sens

itiv

ity

 Boost

Loop Faul

t

1 Flash  = 

Open Lo

op

2 Flashes= Sh

orted Lo

op

3 Flas

hes

=25% chang

e

 

    of In

duct

ance

Both LED’

s Flashing=

   Cu

rrent Loop Fault

PWR 

LED

 Flashing

=

   Pr

evious Lo

op 

Faul

t

EDI

Tel: 480.968.6407

DE

FLEC

TOME

TER

SENS

RESET

POWE

R

DETECT

EDI

SENS

LMA180

0

OPTIONS

1

2

3

4

5

6

7

8

O

N

OPTIONS

ON

1

2

3

4

5

6

7

8

5 = Optim

um

 Se

ns.

   = Incr

ease Sens

.

   = Dec

rease Se

ns.

DEFLECTO

ME

TER

PO

WE

R

ON 

 = 

Nor

mal Power

OFF=

 No Power

LE

D IN

DICA

TORS

DETEC

T

ON 

 = 

Detec

t

OFF= 

No Detect

2 Hz Fl

ash=

Delay 

Timing

SW1 

SW2  

 Frequency

ON 

ON   = Low

ON 

OFF  = Medium-Lo

w

OFF 

ON  

 = Me

dium-High

OFF 

OFF  

= High

SW4 

SW5  

 Output 

B

ON 

ON   = Pulse 

on E

ntr

y

ON 

OFF  = B 

sa

me as

 A

OFF 

ON   

= Pu

lse 

on Exi

t

OF

OFF

  = 

Loo

p Fau

lt

SW

3

ON  

  = 

Fail Secure

OFF 

 =  Fai

l Sa

fe

SW

6

ON  

  = 

2 Sec

on

d D

ela

y

OFF

  =  N

o Dela

y

SW

7

ON  

  = N

orm

al P

rese

nce

OFF 

 =  In

finite

 Presenc

e

SW8

ON  

  = S

ensitiv

ity 

Boo

st

OFF 

 =  N

o Se

nsiti

vity 

Bo

ost

Loop Fau

lt

1 Fl

ash  = Open L

oo

p

2 Flashes

= Sho

rted 

Loo

p

3 Flas

hes=

25%

 change

 

    of

 Indu

ctanc

e

Both 

LED’

s Flashin

g=

   Current

 Lo

op Fa

ult

PWR 

LED

 Flas

hing=

   Pre

vious

 Loop

 Fault

EDI

Tel: 480

.968.640

7

DEF

LECTOMET

ER

SEN

S

RESET

PO

WER

DETEC

T

ED

I

SENS

LMA1800-LP

1

2

3

4

5

6

7

8

O

N

Third party external loop detectors can be used if 
desired with the 

MAX External Loop Detector Cable 

Adapter

. (1) One is included with the operator but 

more can be purchased if needed.

Ext

ernal

Loop

Detector

External Loop Detectors

Plug-In Loop Detectors

Wire to
back of
detector

Plug-In Loop Detector

Safety loops need
to be wired in series.

Power 15 VDC (Red)

Loop Detect
Output (White)

Com, Gnd (Black)

Power Terminal

MAX External Loop

Detector Cable Adapter

MAG

LOCK

MAGLOCK

DELAY

OFF

2Sec

1.5Sec

COM

NC

Tamper NO

COM

GND

Tamper IN

+

+

-

-

Power

Ter

mi

na

l

EMX

Loop Detector
(Plug-In)
MAX Part number:
MAX D-TEK

PO

WER

FRE

Q COUN

T

DE

TE

CT

UL

TR

AME

TE

R

12

3

4

ON   DIP

Dual Gate Operators:

 Primary gate 

opens 

FIRST

. Install maglock 

accordingly to account for this.

Содержание Max Megatron 1400

Страница 1: ...rushless DC Swing Gate Operators Made in USA CONFORMS TO UL STD 325 UL CLASS I II III IV CERTIFIED TO CAN CSA STD C22 2 NO 247 Bi Parting Gates ONLY Single or Bi Parting Gates Single or Bi Parting Gat...

Страница 2: ......

Страница 3: ...Overview Primary Gate Open Left Open Right Close Timer Selectable Gate Speed Control Battery Back Up Mode Anti Tailgate Single Pass Anti Tailgate Radio Receiver Radio Safety Pause Gate in Motion Alarm...

Страница 4: ...1600lbs 12 ft gate per operator 90 Opening Time MAX Megatron 1400 1400HP 2200 16 selectable speeds from approximately 11 5 sec to 20 sec depending on the weight and length of the gate MAX Megatron FAS...

Страница 5: ...rsonnel SECURITY AUTHORIZED PERSONNEL ONLY ul 325 model classifications A Inherent entrapment protection system B1 Provision for connection of a non contact sensor photoelectric sensor or the equivale...

Страница 6: ...art of the gate and where the user is prevented from reaching over under around or through the gate to operate the controls Outdoor or easily accessible controls shall have a security feature to preve...

Страница 7: ...t the gate operator from accidentally closing on vehicles in the gate s closing path and entrapment M ovin g Gate Can Cause Serious In ju ry or Death KE EP CL EA R Ga te may mov e at an y tim e withou...

Страница 8: ...mper NO COM GND T amper IN OFF OFF ON EXIT P ARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH CLAMP SLIPPING MIN MAX 12VDC GND 24VDC GND MAX MIN OF...

Страница 9: ...ION CENT ER REVE RSE SENS ITIVIT Y MOTO R OVER LOAD NO LIMIT SWIT CH CLAM P SLIPP ING MIN MAX 12VD C GND 24VD C GND MAX MIN OFF SAFET Y LEAVE OPEN LEAVE CLOS ED MADE in USA OPEN 1 TIME 2Sec 1 5Se c C...

Страница 10: ...should be installed at the gate bracket height across the ENTIRE gate to keep the gate pickets from bending YES YES NO NO Gate Bracket Support Bar Too High Not Long Enough Support Bar MOTOR Power In...

Страница 11: ...D MAX MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1 5Sec COM NC BATTERY IN USE POWER GATE STATUS MOTOR ON LINE LIMIT SWITCH ON LINE GND PRIMARY GATE GND SEC GATE UL ENTRAP PHOT...

Страница 12: ...com Made in USA BATTERY PACK TO MOTOR CONTROLLER PhotoCell Edge UL Entrap 1 2 Limit SW ON LINE MATRIX JOG LEFT JOG RIGHT Jog LT Jog RT GND Edge 1 Edge 2 Photo Cell ERD Motor OverLoad POWER MC 200 Moto...

Страница 13: ...tely install a Remote MAX Megatron Toroid box Install the MAX Magic Box near the 115 VAC or 230 VAC input AC power source up to 1000 ft away from gate operator NOTE A MAX Magic Box kit is required for...

Страница 14: ...IMIT 2 4 V GND UL ALARM 12V ALARM RET RESET GND GA TE T AMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELA Y PRIMARY GA TE SAFETY CENTER EXIT OPEN MAX GA TE SPEED STOP CLOSE ANTI T AILGA TE CLOSE TIMER...

Страница 15: ...onitored Normally Closed Type IMPORTANT Sensing edges MUST be Monitored 10K Normally Closed Type and a GEM 104 module MUST be installed Closed Gate Max 10K Mini Sensing Edge N C Hinge Area End of Gate...

Страница 16: ...ired in series MOTOR ON LINE LIMIT SWITCH ON LINE 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED S...

Страница 17: ...FETY CENT ER EXIT OP EN MAX GA TE SP EED STOP CLOS E AN TI TAILGA TE CLOS E TIMER PO SITION RE CO RD ER ID PLUG AUTOMATIC OPEN CLOSE CONTROLS BATTER Y BA CK UP MOD E MATRIX 1 PH OT OC ELL ED GE 1 ED...

Страница 18: ...Battery Button Press to show amount of battery power available when using battery power ONLY Battery voltage LEDs will light respectively Battery IN Error LED Lights when there is a battery connectio...

Страница 19: ...t End of Gate Options GND C P h o to C e ll E d g e U L E n tr a p 1 2 L im it S W O N L IN E M A T R IX J O G L E F T J O G R I G H T J o g L T J o g R T G N D E d g e 1 E d g e 2 P h o to C e ll E R...

Страница 20: ...AD RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG RADIO GND OPEN STOP CLOSE COM GATE DISABLE E TIMER CENTER MAX MIN OFF SAFETY POSITION CORDER OPEN STOP CLOSE MOTOR MOTION Inputs MUST be LEARNED to MONI...

Страница 21: ...rotec tio n co ntre les ris qu es d ince nd ie utilise r un fusible de m m es type et ca ract ristiq ue s no minales AC IN Power LED M A X M e g a t r o n T o r o i d B o x disconnect power before ser...

Страница 22: ...Polarity Matters Remove the Remote Toroid 15 Amp connector from the BC 7 battery module POWER SOLAR IN port Plug the Magic Box POWER SOLAR IN connector into the POWER SOLAR IN port NOTE A MAX Magic Bo...

Страница 23: ...e BATTERY IN POWER SOLAR IN POWER IN Battery Pack TO MOTOR CONTROLLER w w w M a x U S c o m BATTERY IN POWER SOLAR IN Refer to Solar application guide Max Solar Power Kit Sold separately Connect to PO...

Страница 24: ...ge Re pla ce Ba tte ry TE ST Ba tte ry Ba tte ry IN Err or MAX BC 7 Ba tte ry Mo du le B A T T E R Y IN P O W E R S O L A R IN P O W E R IN B a tt e ry P a c k T O M O T O R C O N T R O L L E R w w w...

Страница 25: ...t 2 or 3 3 Press an d HOLD the OPEN STO P bu tto ns at the sa me tim e on Matrix 1 un til be ep is he ard learn mod e be gins Le arn mod e lasts for 5 min indica ted by be ep ing 4 LE Ds WILL be ON f...

Страница 26: ...le attempts to tailgate The second vehicle must then back off the safety loop for the gate to continue closing A new radio signal will open the gate When turned ON a moving gate will pause if a radio...

Страница 27: ...Dual Gates See page 34 See page 28 Emergency OPEN Overrides gate disable switch MAX OPEN Overrides gate disable switch 4 Wire Radio 3 Wire Radio Emergency Security Devices Normal Opening Devices Norm...

Страница 28: ...rements for each successive click up to 60 sec MAX NOTE 1 2 sec MIN position is recommended for High Traffic areas gate close timer MOTOR ON LINE LIMIT SWITCH ON LINE 24V GND UL ALARM 12V ALARM RET RE...

Страница 29: ...L GND STRIKE GND KEYPAD RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG RADIO GND OPEN STOP CLOSE COM GATE DISABLE MOTOR ON LINE LIMIT SWITCH ON LINE SAFETY ANTI TAILGATE OFF ON AUTHORIZED Vehicle UNAUTH...

Страница 30: ...BATTERY IN USE POWER GATE STATUS GND PRIMARY GATE GND SEC GATE UL ENTRAP PHOTOCELL GND STRIKE GND KEYPAD RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG RADIO GND OPEN STOP CLOSE COM GATE DISABLE ID PLU...

Страница 31: ...when there is an error with the corresponding loop detector NOTE Reno H2 detector always blinks steadily during normal operation MOTOR ON LINE LIMIT SWITCH ON LINE 24V GND UL ALARM 12V ALARM RET RESE...

Страница 32: ...MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH CLAMP SLIPPING MIN MAX 12VDC GND 24VDC GND MAX MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1 5Sec COM NC BATTER...

Страница 33: ...FF OFF ON EXIT PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH CLAMP SLIPPING MAX 12VDC GND 24VDC GND MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE...

Страница 34: ...TATUS GATE OPEN GATE CLOSED OPEN STOP STOP CLOSE Com Power GND GND N O Com MOTOR ON LINE LIMIT SWITCH ON LINE 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK...

Страница 35: ...MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON EXIT PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMI...

Страница 36: ...ONITO R se ns ors To LE AR N inpu ts 1 MONITO RE D Se ns ors MUS T be wired to inpu ts BE FO RE they ca n be learne d An y un us ed inpu ts MUS T be jumpe red 2 Re ve rsing Ed ge an d or Ph oto Ce ll...

Страница 37: ...the button to stop gate This allows gate to be moved back and fourth without leaving the operator to fine tune the open and close gate positions if desired Adjustments open and close limits CLOSED LI...

Страница 38: ...eadjustment is necessary After Release Handle Clamp is in the SECURE HORIZONTAL position Pull the arm NO slippage should occur If it does readjust Adjustment Bolt factory set bolt DO NOT adjust adjust...

Страница 39: ...tes LED is off B Turn knob counter clockwise to reduce sensitivity during ERD testing as needed LED remains OFF for all but position 1 IMPORTANT When satisfied with ERD adjustment cycle the gate 3 or...

Страница 40: ...home owner must call a qualified professional gate operator technician for any repairs and modifications The gate operator is virtually maintenance free to an end user home owner minimal maintenance i...

Страница 41: ...NC BATTERY IN USE POWER GATE STATUS MOTOR ON LINE LIMIT SWITCH ON LINE GND PRIMARY GATE GND SEC GATE UL ENTRAP PHOTOCELL GND STRIKE GND KEYPAD RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG RADIO GND OP...

Страница 42: ...nics Box MAX BC 7 Battery Module BATTERY IN POWER SOLAR IN POWER IN Battery Pack TO MOTOR CONTROLLER www Max US com CLOSED LIMIT OPEN LIMIT To SEC GATE input on Matrix 1 Motor MAX Megatron Toroid Box...

Страница 43: ...hood and remove it 2 Make sure ALL power is OFF to operator 1 Pull red handle up and move gate 3 maintenance manual gate release Arm WARNING WARNING NEVER grasp the arm to move gate Pinch Point Arm AL...

Страница 44: ...econd obstruction occurred CHECK THE GATE AREA FOR ANY PROBLEMS BEFORE pressing the STOP button on the Matrix 1 or the externally mounted Alarm Reset button to shut off the alarm and reset the gate NO...

Страница 45: ...HO TOC ELL EDG E 1 EDG E 2 ID PLU G ERR OR OPE N COM CLO SE Tam per NO COM GND Tam per IN OFF OFF ON EXIT PAR TIAL OPE N OBD POR T BLA CK BOX MO TOR MO TIO N CENT ER REVE RSE SENS ITIVI TY MOT OR OVER...

Страница 46: ...e without an RMA number Shipping charges to and from the factory service center for warranty repairs are the responsibility of the customer Repair or replacement of any warranty items is made at the s...

Страница 47: ...te the relay when a number of security circumstances occur making illegal entry almost impossible when the gate operator is connected to a existing building home alarm system The GATE TAMPER relay wil...

Страница 48: ...O PRI_MC Fully Open Posi on Learned Fri 07 11 2014 10 58 53 INFO SEC_MC Fully Open Posi on Learned Fri 07 11 2014 10 57 40 INFO PRI_CIO Communica on Established Fri 07 11 2014 10 57 38 ENTRAP PRI_MC P...

Страница 49: ...47...

Страница 50: ...48...

Страница 51: ...49...

Страница 52: ...99 0220 www max us com 4009963 CONFORMS TO UL STD 325 UL CLASS I II III IV CERTIFIED TO CAN CSA STD C22 2 NO 247 Residential Commercial Brushless DC Swing Gate Operators Made in USA 14 0 0 H P 14 0 0...

Отзывы: