background image

2

5

ma

trix 1

24V

GND

UL ALARM 12V

ALARM RET

RESET

GND

GATE

TAMPER

MAG

LOCK

OPEN

RIGHT

OPEN

LEFT

MAGLOCK

DELAY

PRIMARY

GATE

SAFETY

CENTER

EXIT

OPEN

MAX

GATE SPEED

STOP

CLOSE

ANTI

TAILGATE

CLOSE TIMER

POSITION

RECORDER

ID

PLUG

AUTOMATIC OPEN/CLOSE CONTROLS

BATTERY

BACK-UP MODE

MATRIX 1

PHOTOCELL

EDGE 1

EDGE 2

ID PLUG

ERROR

OPEN

COM

CLOSE

Tamper NO

COM

GND

Tamper IN

OFF

OFF

ON

EXIT

PARTIAL

OPEN

OBD PORT

BLACK BOX

MOTOR MOTION

CENTER

REVERSE SENSITIVITY

MOTOR OVERLOAD

NO LIMIT SWITCH /

CLAMP SLIPPING

MIN

MAX

12VDC

GND

24VDC

GND

MAX

MIN

OFF

SAFETY

LEAVE

OPEN

LEAVE

CLOSED

MADE in USA

OPEN
1 TIME

2Sec

1.5Sec

COM

NC

BATTERY

IN USE

POWER

GATE

STATUS

MOTOR

ON-LINE

LIMIT

SWITCH

ON-LINE

(+)

GND

(-)

PRIMARY

GATE

(+)

GND

(-)

SEC

GATE

 

UL

ENTRAP

PHOTOCELL

GND

STRIKE

GND

KEYP

AD / RDR

GND

FIRE DEPT

GND

MAX OPEN

GND

RADIO SIG.

RADIO GND

OPEN

STOP

CLOSE

COM

GA

TE DISABLE

Power

RS-485

Stop

3-Button
Station
See page 32.

External Alarm

Reset Button

See page 32.

Gate Disable
Switch or Timer
See page 31.

Secondary Operator

Connect to MC-200
See pages 22 & 33.

In-Ground Loops
See page 29.

Loop Detectors

See page 29.

Safety Loops

Wired in series

Center

Loop

Safety

Loo

p

Safety

Loop

Exit

Loop

Gate Tamper:

See page 30.

24V Power for Matrix 1 from

Primary

 operator 

ONLY

See page 33.

ID Plug:

See page 30

ID Plug Error LED. See page 30.

ON

OF

F

ON

1

2

3

4

5

6

7

8

5 = 

Optimum Sens

.

   = 

Inc

rease Sens.

   = Decre

ase S

ens.

DE

FLECTOMETER

POWER

ON  = 

Nor

mal Powe

r

OFF= N

o Po

wer

LED

 INDICA

TO

RS

DETEC

T

ON  = D

etect

OFF= N

o D

etec

t

2 Hz

 Fla

sh=D

elay 

Tim

ing

SW1 

SW

2   Frequen

cy

ON

 

ON   = 

Low

ON

 OFF 

 = Medium

-Low

OFF

 ON

   = Medi

um-High

OFF

 

OFF 

 = H

igh

SW4 

SW5

   O

utput B

ON 

ON   =

 Pu

lse 

on Entr

y

ON 

OFF 

 = B sam

e a

s A

OFF

 

ON   = Pu

lse on Exit

OFF

 

OFF 

 = Loop 

Fault

SW

3

ON   

 = Fail

 Se

cure

OFF

  =  Fa

il Sa

fe

SW

6

ON    

= 2

 Secon

d D

elay

OFF

  =  No D

elay

SW

7

ON   

 = N

ormal

 Pres

enc

e

OFF

  =  I

nfini

te 

Presence

SW

8

ON

    = Sensitivit

y Boost

OFF

  =  

No Sensi

tivity Boos

t

Loop Fault

1 Fl

ash

  = Open Loop

2 Fla

she

s= 

Sho

rted Loop

3 Fl

ash

es=

25%

 ch

ang

e

 

    of In

ducta

nce

Bo

th LE

D’s Fl

ashin

g=

   Cu

rren

t Loo

p Fa

ult

PWR

 LED 

Flash

ing=

   Pr

evious

 Loop

 Fa

ult

ED

I

Tel: 480.968.640

7

DE

FLECTO

METER

SEN

S

RESE

T

POW

ER

DE

TEC

T

ED

I

SEN

S

LMA180

0

OPTIONS

1

2

3

4

5

6

7

8

O

N

UL LED Indicators 

ONLY

.

See page 30.

Strobe Light

12VDC

250mA Max

See page 32.

Security Device

Security Device

Normal

Opening

Device

GA

TE OPEN

GA

TE CLOS

ED

Maglock Connection: 

Must be specifically 

wired,

 

See page 29.

matrix 1

PR

ES

S

to RESET

Motion
Sensor

Security

Camera

Gate Status: 

See page 32

.

wiring Overview

12 VDC

OR

 24 VDC

Radio Power

12 VDC 

OR

 24 VDC

Photocell

Power

Card Reader

Separate

 power

for Devices.

Keypad

Photocell (N.O.)

250 mA Max.

Key Switch

Telephone Entry

     External
Open/Close
Key Switch
with Dual
Gates
See page 34.

See page 28.

Emergency OPEN

(Overrides gate

disable switch)

MAX OPEN

(Overrides gate

disable switch)

4-Wir

e

Radi

o

3-Wire

Radio

Emergency/Security Devices

Normal Opening Devices

Normal

Opening

Device

Dry Contact

(N.O.)

Dry Contact (N.O.)

(N.O.)

(N.O.)

See page 30.

Normally Closed 

Photocell

See page 13 &17.

1400

2200

FAST

MAX

MEGA

T

RON

1400

MA

X

MEG

AT

RO

N

FA

S

T

MAX

MEG

AT

R

O

N

2200

Pho

toCell

Edge

UL

 E

ntr

ap

1

2

Limi

t S

W

ON-

LIN

E

MA

TR

IX

JO

G

LEF

T

JOG

RI

GHT

Jog

 LT

Jo

g RT

GN

D

Ed

ge

 1

Ed

ge

 2

Ph

oto

Cell

ER

D

Mo

tor

Ove

rLo

ad

PO

WE

R

MC

-200

Mo

tor

 Co

ntr

oll

er

16

15

14

13

12

3

4

5

MA

X

LE

ON

Ed

ge

Se

nsi

tivi

ty

ERD

MOT

OR

Po

wer

 In

AL

ARM

BA

TT

ER

Y

PA

CK

LIMIT

SW

ITCH

MO

TOR

INPUT

S

PWR 12V

 

-

GND

 

-

-

-

PWR 24V -  

GND -  

RS-485 (-) -  

RS-485 (+) -  

MAT

RI

1

Edge 1

Moni

to

red

Rever

sing

Ed

ge

Moni

tored

Phot

o

Cel

l

OR

GND

Jog RT

Jog L

T

Entr

apmen

t Pr

otectio

n

Inp

uts: 

MU

ST

 jum

per

unused

 in

put

s

En

trapme

nt 

Pro

tection

Senso

r Gu

idelines

1

-

-

-

CA

UTI

ON

:

 Se

e i

ns

tal

lat

ion

 ins

truc

tions

.

AT

TE

NTI

ON

:

 Vo

ir la 

not

ice

 d’

inst

all

ation.

 Edge 2

Photo Cell

MC

-200

 

PW

12

V

 

MU

ST

 be

 us

ed

ON

LY

 powe

r entrapment

 pro

tec

tio

se

ns

or

s wi

th

 M

C-

200

 PW

R 12

V

Input

s     

&    

 MU

ST be

 “L

EA

RNE

D” 

to MO

NIT

OR 

se

nsors

.

To LE

AR

N input

s     

&     

:

1.

 

MO

NIT

OR

ED

 Se

nso

rs 

MU

ST

 be

  w

ire

d t

o i

npu

ts 

BEF

OR

E

 th

ey 

ca

n be

 

  l

ea

rne

d. 

An

y u

nu

se

d i

np

uts

 

MU

ST

 be

 

  j

um

pe

red

.

2.

 Re

ve

rsi

ng

 Ed

ge

 an

d/o

r P

ho

to 

Cel

l ca

  b

e w

ire

d t

o e

ith

er i

np

ut 

2 o

r 3

.

3.

 Pr

ess 

an

HO

LD

 the

 

OPE

ST

OP

 

  b

utton

s a

t th

e sa

me

 tim

e o

Mat

rix

 1

 

  u

nti

l be

ep

 is 

he

ard

, le

arn

 m

od

e b

eg

ins.

 

Le

arn m

od

e l

ast

s f

or 5

 m

in.

 in

dica

ted

 

  b

y b

ee

pin

g.

4.

 LED

WI

LL

 be

 

ON

 fo

r e

ach

 de

tect

ed

 

  se

nso

r o

n M

C-

20

0. 

LED

WI

LL

 be 

ON

 

  f

or 

BO

TH

 M

C-20

0s 

wh

en

 du

al 

  o

pe

rat

ors 

are

 use

d.

5.

 Pr

ess 

ST

OP

 bu

tto

n ag

ain 

wi

thi

n 5

 m

in.

 

  t

o l

ea

rn 

se

nso

rs an

d e

nd

 le

arn

 m

od

e, 

  b

ee

pin

g st

ops.

  I

npu

ts 

are

 no

MON

ITO

RE

D

.

2

3

2

3

2

3

 

A s

en

so

MUST

 be

 w

ired

 to 

ED

GE 1

 or

 

  o

per

ator 

W

ILL

 N

OT

 funct

ion. 

 

Wi

re 

NOR

MA

LL

CL

OSED

 

(N

.C

.)

 

  M

ON

ITOR

ED

 se

nsor

ONL

Y

, to 

each 

  o

per

ator

’s 

MC

-200

 w

hen 

dua

l ope

rat

ors 

  a

re u

sed.

 

Rever

sing 

Ed

ge

 and/

or 

Ph

oto

 C

ell

 ca

  b

e w

ire

d t

AN

Y

 of

 th

e 3

 

Input

s.

 M

C-

200 

PW

12V

 

MU

ST

 be 

use

d t

  p

ow

er 

MON

ITOR

ED

 

se

nsors.

 U

NU

SED

 in

pu

ts 

MU

ST

 rema

in

  J

UM

PER

ED

 or

 fa

ult wi

ll oc

cu

r.

GND

1

2

3

OPEN

ST

OP

CLOS

E

MO

TO

MO

TIO

N

MC-200 Swing

UL 325

Type B2

UL 325
Type B1

Power

Wireless
Sensing Edge
Radio Receiver

ON = Obstruction
BLINKING = Fault

PWR

MON.
SAFETY
INPUT

GEM - 104

10K Edge

PO

WER

ST

ATU

S

LE

AR

N

CH

 1

CH

 2

CO

M

P/N

. C

.

10K

CO

M

P/N

. C.

10

K

PO

WER

CH 

1

CH

 2

Mo

nit

ored 

Gat

e L

ink

MG

L-R

20

OU

TP

UT

SELE

CT

P

R

Normally
Closed

10K Sensing Edge
wiring, See
page 13 &17.

GEM-104

MC-200
Motor
Controller 

Refer to wireless
manual for more
information.

page 17 &18

Normally Open

 Closing Photocell 

ONLY.

See page 32 (Typically Retro-fit).

NOT 

UL 325 entrapment protection.

Содержание Max Megatron 1400

Страница 1: ...rushless DC Swing Gate Operators Made in USA CONFORMS TO UL STD 325 UL CLASS I II III IV CERTIFIED TO CAN CSA STD C22 2 NO 247 Bi Parting Gates ONLY Single or Bi Parting Gates Single or Bi Parting Gat...

Страница 2: ......

Страница 3: ...Overview Primary Gate Open Left Open Right Close Timer Selectable Gate Speed Control Battery Back Up Mode Anti Tailgate Single Pass Anti Tailgate Radio Receiver Radio Safety Pause Gate in Motion Alarm...

Страница 4: ...1600lbs 12 ft gate per operator 90 Opening Time MAX Megatron 1400 1400HP 2200 16 selectable speeds from approximately 11 5 sec to 20 sec depending on the weight and length of the gate MAX Megatron FAS...

Страница 5: ...rsonnel SECURITY AUTHORIZED PERSONNEL ONLY ul 325 model classifications A Inherent entrapment protection system B1 Provision for connection of a non contact sensor photoelectric sensor or the equivale...

Страница 6: ...art of the gate and where the user is prevented from reaching over under around or through the gate to operate the controls Outdoor or easily accessible controls shall have a security feature to preve...

Страница 7: ...t the gate operator from accidentally closing on vehicles in the gate s closing path and entrapment M ovin g Gate Can Cause Serious In ju ry or Death KE EP CL EA R Ga te may mov e at an y tim e withou...

Страница 8: ...mper NO COM GND T amper IN OFF OFF ON EXIT P ARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH CLAMP SLIPPING MIN MAX 12VDC GND 24VDC GND MAX MIN OF...

Страница 9: ...ION CENT ER REVE RSE SENS ITIVIT Y MOTO R OVER LOAD NO LIMIT SWIT CH CLAM P SLIPP ING MIN MAX 12VD C GND 24VD C GND MAX MIN OFF SAFET Y LEAVE OPEN LEAVE CLOS ED MADE in USA OPEN 1 TIME 2Sec 1 5Se c C...

Страница 10: ...should be installed at the gate bracket height across the ENTIRE gate to keep the gate pickets from bending YES YES NO NO Gate Bracket Support Bar Too High Not Long Enough Support Bar MOTOR Power In...

Страница 11: ...D MAX MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1 5Sec COM NC BATTERY IN USE POWER GATE STATUS MOTOR ON LINE LIMIT SWITCH ON LINE GND PRIMARY GATE GND SEC GATE UL ENTRAP PHOT...

Страница 12: ...com Made in USA BATTERY PACK TO MOTOR CONTROLLER PhotoCell Edge UL Entrap 1 2 Limit SW ON LINE MATRIX JOG LEFT JOG RIGHT Jog LT Jog RT GND Edge 1 Edge 2 Photo Cell ERD Motor OverLoad POWER MC 200 Moto...

Страница 13: ...tely install a Remote MAX Megatron Toroid box Install the MAX Magic Box near the 115 VAC or 230 VAC input AC power source up to 1000 ft away from gate operator NOTE A MAX Magic Box kit is required for...

Страница 14: ...IMIT 2 4 V GND UL ALARM 12V ALARM RET RESET GND GA TE T AMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELA Y PRIMARY GA TE SAFETY CENTER EXIT OPEN MAX GA TE SPEED STOP CLOSE ANTI T AILGA TE CLOSE TIMER...

Страница 15: ...onitored Normally Closed Type IMPORTANT Sensing edges MUST be Monitored 10K Normally Closed Type and a GEM 104 module MUST be installed Closed Gate Max 10K Mini Sensing Edge N C Hinge Area End of Gate...

Страница 16: ...ired in series MOTOR ON LINE LIMIT SWITCH ON LINE 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED S...

Страница 17: ...FETY CENT ER EXIT OP EN MAX GA TE SP EED STOP CLOS E AN TI TAILGA TE CLOS E TIMER PO SITION RE CO RD ER ID PLUG AUTOMATIC OPEN CLOSE CONTROLS BATTER Y BA CK UP MOD E MATRIX 1 PH OT OC ELL ED GE 1 ED...

Страница 18: ...Battery Button Press to show amount of battery power available when using battery power ONLY Battery voltage LEDs will light respectively Battery IN Error LED Lights when there is a battery connectio...

Страница 19: ...t End of Gate Options GND C P h o to C e ll E d g e U L E n tr a p 1 2 L im it S W O N L IN E M A T R IX J O G L E F T J O G R I G H T J o g L T J o g R T G N D E d g e 1 E d g e 2 P h o to C e ll E R...

Страница 20: ...AD RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG RADIO GND OPEN STOP CLOSE COM GATE DISABLE E TIMER CENTER MAX MIN OFF SAFETY POSITION CORDER OPEN STOP CLOSE MOTOR MOTION Inputs MUST be LEARNED to MONI...

Страница 21: ...rotec tio n co ntre les ris qu es d ince nd ie utilise r un fusible de m m es type et ca ract ristiq ue s no minales AC IN Power LED M A X M e g a t r o n T o r o i d B o x disconnect power before ser...

Страница 22: ...Polarity Matters Remove the Remote Toroid 15 Amp connector from the BC 7 battery module POWER SOLAR IN port Plug the Magic Box POWER SOLAR IN connector into the POWER SOLAR IN port NOTE A MAX Magic Bo...

Страница 23: ...e BATTERY IN POWER SOLAR IN POWER IN Battery Pack TO MOTOR CONTROLLER w w w M a x U S c o m BATTERY IN POWER SOLAR IN Refer to Solar application guide Max Solar Power Kit Sold separately Connect to PO...

Страница 24: ...ge Re pla ce Ba tte ry TE ST Ba tte ry Ba tte ry IN Err or MAX BC 7 Ba tte ry Mo du le B A T T E R Y IN P O W E R S O L A R IN P O W E R IN B a tt e ry P a c k T O M O T O R C O N T R O L L E R w w w...

Страница 25: ...t 2 or 3 3 Press an d HOLD the OPEN STO P bu tto ns at the sa me tim e on Matrix 1 un til be ep is he ard learn mod e be gins Le arn mod e lasts for 5 min indica ted by be ep ing 4 LE Ds WILL be ON f...

Страница 26: ...le attempts to tailgate The second vehicle must then back off the safety loop for the gate to continue closing A new radio signal will open the gate When turned ON a moving gate will pause if a radio...

Страница 27: ...Dual Gates See page 34 See page 28 Emergency OPEN Overrides gate disable switch MAX OPEN Overrides gate disable switch 4 Wire Radio 3 Wire Radio Emergency Security Devices Normal Opening Devices Norm...

Страница 28: ...rements for each successive click up to 60 sec MAX NOTE 1 2 sec MIN position is recommended for High Traffic areas gate close timer MOTOR ON LINE LIMIT SWITCH ON LINE 24V GND UL ALARM 12V ALARM RET RE...

Страница 29: ...L GND STRIKE GND KEYPAD RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG RADIO GND OPEN STOP CLOSE COM GATE DISABLE MOTOR ON LINE LIMIT SWITCH ON LINE SAFETY ANTI TAILGATE OFF ON AUTHORIZED Vehicle UNAUTH...

Страница 30: ...BATTERY IN USE POWER GATE STATUS GND PRIMARY GATE GND SEC GATE UL ENTRAP PHOTOCELL GND STRIKE GND KEYPAD RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG RADIO GND OPEN STOP CLOSE COM GATE DISABLE ID PLU...

Страница 31: ...when there is an error with the corresponding loop detector NOTE Reno H2 detector always blinks steadily during normal operation MOTOR ON LINE LIMIT SWITCH ON LINE 24V GND UL ALARM 12V ALARM RET RESE...

Страница 32: ...MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH CLAMP SLIPPING MIN MAX 12VDC GND 24VDC GND MAX MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1 5Sec COM NC BATTER...

Страница 33: ...FF OFF ON EXIT PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH CLAMP SLIPPING MAX 12VDC GND 24VDC GND MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE...

Страница 34: ...TATUS GATE OPEN GATE CLOSED OPEN STOP STOP CLOSE Com Power GND GND N O Com MOTOR ON LINE LIMIT SWITCH ON LINE 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK...

Страница 35: ...MATRIX 1 PHOTOCELL EDGE 1 EDGE 2 ID PLUG ERROR OPEN COM CLOSE Tamper NO COM GND Tamper IN OFF OFF ON EXIT PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMI...

Страница 36: ...ONITO R se ns ors To LE AR N inpu ts 1 MONITO RE D Se ns ors MUS T be wired to inpu ts BE FO RE they ca n be learne d An y un us ed inpu ts MUS T be jumpe red 2 Re ve rsing Ed ge an d or Ph oto Ce ll...

Страница 37: ...the button to stop gate This allows gate to be moved back and fourth without leaving the operator to fine tune the open and close gate positions if desired Adjustments open and close limits CLOSED LI...

Страница 38: ...eadjustment is necessary After Release Handle Clamp is in the SECURE HORIZONTAL position Pull the arm NO slippage should occur If it does readjust Adjustment Bolt factory set bolt DO NOT adjust adjust...

Страница 39: ...tes LED is off B Turn knob counter clockwise to reduce sensitivity during ERD testing as needed LED remains OFF for all but position 1 IMPORTANT When satisfied with ERD adjustment cycle the gate 3 or...

Страница 40: ...home owner must call a qualified professional gate operator technician for any repairs and modifications The gate operator is virtually maintenance free to an end user home owner minimal maintenance i...

Страница 41: ...NC BATTERY IN USE POWER GATE STATUS MOTOR ON LINE LIMIT SWITCH ON LINE GND PRIMARY GATE GND SEC GATE UL ENTRAP PHOTOCELL GND STRIKE GND KEYPAD RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG RADIO GND OP...

Страница 42: ...nics Box MAX BC 7 Battery Module BATTERY IN POWER SOLAR IN POWER IN Battery Pack TO MOTOR CONTROLLER www Max US com CLOSED LIMIT OPEN LIMIT To SEC GATE input on Matrix 1 Motor MAX Megatron Toroid Box...

Страница 43: ...hood and remove it 2 Make sure ALL power is OFF to operator 1 Pull red handle up and move gate 3 maintenance manual gate release Arm WARNING WARNING NEVER grasp the arm to move gate Pinch Point Arm AL...

Страница 44: ...econd obstruction occurred CHECK THE GATE AREA FOR ANY PROBLEMS BEFORE pressing the STOP button on the Matrix 1 or the externally mounted Alarm Reset button to shut off the alarm and reset the gate NO...

Страница 45: ...HO TOC ELL EDG E 1 EDG E 2 ID PLU G ERR OR OPE N COM CLO SE Tam per NO COM GND Tam per IN OFF OFF ON EXIT PAR TIAL OPE N OBD POR T BLA CK BOX MO TOR MO TIO N CENT ER REVE RSE SENS ITIVI TY MOT OR OVER...

Страница 46: ...e without an RMA number Shipping charges to and from the factory service center for warranty repairs are the responsibility of the customer Repair or replacement of any warranty items is made at the s...

Страница 47: ...te the relay when a number of security circumstances occur making illegal entry almost impossible when the gate operator is connected to a existing building home alarm system The GATE TAMPER relay wil...

Страница 48: ...O PRI_MC Fully Open Posi on Learned Fri 07 11 2014 10 58 53 INFO SEC_MC Fully Open Posi on Learned Fri 07 11 2014 10 57 40 INFO PRI_CIO Communica on Established Fri 07 11 2014 10 57 38 ENTRAP PRI_MC P...

Страница 49: ...47...

Страница 50: ...48...

Страница 51: ...49...

Страница 52: ...99 0220 www max us com 4009963 CONFORMS TO UL STD 325 UL CLASS I II III IV CERTIFIED TO CAN CSA STD C22 2 NO 247 Residential Commercial Brushless DC Swing Gate Operators Made in USA 14 0 0 H P 14 0 0...

Отзывы: