![maxem Maxem 5 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/maxem/maxem-5/maxem-5_installation-manual_1743640008.webp)
8
•
A correct circuit breaker or earth leakage circuit breaker with proper fusing value.
See
p. 33 to determine fusing.
•
Schuko sockets for 230V power supply Maxem (if not already available).
•
UTP (CAT5 or CAT6) data cable for connecting charging station to Maxem.
•
RJ45 (8P8C) connectors for ethernet connected charging stations (ICU / Keba).
•
Cable end sleeves for UTP cores (only for Tesla Wall Connector).
•
Internet connected smartphone, tablet or computer.
Required materials
01 - Voorbereidingen vooraf
What do I need for the installation?
Wired Internet access
With Maxem compatible charging stations
Compatibility may change over time. See the website www.maxem.io for the current
overview of compatible charging stations.
Tesla Wall Connector
ICU EVe mini
KEBA P20/P30
ICU EVe
The following network settings are required. Don’t be alarmed by the jargon, these are
normal network settings. In corporate networks some options can be blocked:
•
Maxem has to receive an IP address via DHCP.
•
This IP address may not be in the following range: 10.50.0.0/16, 10.51.0.0/16, and
192.168.25.1/24.
•
In case of a firewall outgoing traffic has to be allowed on the following ports: 80, 443,
1194 t/m 1200 and 9090.