Place the kWh-meter on a DIN-rail in the fuse box.
Connecting an MID kWh-meter
Connect the green Phoenix connector to port RS1 on Maxem.
Connect behind the main circuit breaker so that it measures the output of the
complete grid connection. Notice that this kWh-meter is fed from the top end.
Set the address of the kWh-meter to corresponding node.
SET
OK
1 2 3
Connection RS485 cable
on kWh-meter
A.
B.
D.
E.
RS1 port for
MID kWh-meter
REVISION
TITLE:
A4
DWG NO.
SCALE:1:2
SHEET 1 OF 2
WEIGHT:
A
A
B
B
C
C
D
D
E
E
F
F
4
4
3
3
2
2
1
DATE
SIGNATURE
DO NOT SCALE DRAWING
MATERIAL:
NAME
1
DRAWN
LINEAR:
CHK'D
APPV'D
MFG
Q.A
ANGULAR:
FINISH:
TOLERANCES:
EDGES
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN MILLIMETERS
SURFACE FINISH:
DEBURR AND
BREAK SHARP
Maxem5-R4
Connection RS485 cable
on Phoenix connector
C B A
Connect a 1-phase solar installation which supplies L3 of the main grid connection
also to L3 of the kWh-meter. The same goes for L2.
Connect the RS485 cable to the kWh-
meter and the supplied green Phoenix
connector as follows:
kWh-
meter
Wire
color
Phoenix-
connector
A
Brown
1
B
White
2
C
Green
3
C.
2
1
3