12.0
COMMUNICATION (OPTIONAL)
www.maxcessintl.com
MAGPOWR Spyder-Plus
MI 850A320 1 M
Page 57 of 60
Starting
Modbus
Register
Parameter Name
Parameter
Format
Parameter
Type
Used with
Control
Types
Read /
Write
Range
0x99
Actual Output
FLOAT
None
LC, DT, DS,
OPT
Read
Only
{ 0.0 - 100.0 } %
0x9B
Actual Diameter
FLOAT
None
LC, OPT
Read
Only
{ 0.0 - 999.0 } in.
0x9D
Position Setpoint
FLOAT
None
DT, DS
Read
Only
{ 0.0 - 100.0 } %
0x9F
Actual Position
FLOAT
None
DT, DS
Read
Only
{ 0.0 - 100.0 } %
0xA1
Device Name
STRING
Data
LC, DT, DS,
OPT
Read /
Write
31 Characters Maximum
0xB1
Program Version
UINT32
None
LC, DT, DS,
OPT
Read
Only
920Axxx.yyy
xxx,yyy={0 - 999}
xxx = High Word
yyy = Low Word
0xB3
Modbus Address
UINT16
Data
LC, DT, DS,
OPT
Read /
Write
{ 0 - 255 }
0xB4
Modbus Byte Order
BYTE
Data
LC, DT, DS,
OPT
Read /
Write
0 = MSB First
1 = LSB First
0xB5
Modbus Word Order
BYTE
Data
LC, DT, DS,
OPT
Read /
Write
0 = MSB First
1 = LSB First
0xB6
Actual Manual Level
FLOAT
None
LC, OPT
Read
Only
{ 0.0
– 100.0 } %
0xB8
Enable Load Cell Reading (Dancer)
BYTE
Data
DT, DS
Read /
Write
0 = Load Cells Not Enabled
1 = Load Cells Enabled
0xB9
Remote Dancer Setpoint
FLOAT
Data
DT, DS
Read /
Write
No Integrator, mode: P or
PD, range = { 0.0
– 5.0 }
With Integrator, mode PI or
PID, range = { 0.0
– 1.0 }.
Multiply this value by 100 to
get percent.
0xBB
Setpoint Tension Percent
FLOAT
Data
OPT
Read/
Write
{ 0.0
– 100.0 } %
0xBD
System Type (Open Loop Tension )
BYTE
Data
OPT
Read/
Write
0 = Unwind
1 = Rewind
0xBE
Core Offset
FLOAT
Data
OPT
Read/
Write
{ -20.0
– 100.0 } %
0xC0
Actaul Tension Setpoint Percent
FLOAT
None
OPT
Read
Only
{ 0.0
– 100.0 } %
0xC2
Actual Tension Percent
FLOAT
None
OPT
Read
Only
{ 0.0
– 100.0 } %
0xC4
Initial Screen (Open Loop Tension)
BYTE
Data
OPT
Read/
Write
0 = Operator Menu
1 = Tension
2 = Output Level
3 = Diameter
0xC5
Hold Level Multiplier
FLOAT
Data
DT
Read/
Write
[0.0-99.0}
12.8
MODBUS MASTER PROGRAM
There is a Modbus master program available to test communications with the Spyder that runs on a PC with
Windows. This program was written as an engineering debugging tool for Modbus software development and is
provided as is. Go to
www.maxcessintl.com
. Type the keywords
“spyder modbus” in the Search field and press
the Enter key. When the results are displayed, select
Software
in the filter list on the left
–
do not click Search a
second time
. When results are displayed, click on
Spyder Modbus TCP Master Software,
which links to a zip file.
Save the zip file to a directory on your computer. Unzip this file and run the SMM.exe file. Use the Configure
screen to set up IP address of the Spyder, update rate and Spyder Program Number. The Spyder program number
is displayed on the Spyder for a few seconds after applying power.