11.0
ALPHABETICAL LIST OF SCREEN DEFINITIONS
www.maxcessintl.com
MAGPOWR Spyder-Plus
MI 850A320 1 M
Page 48 of 60
Secondary tuning is optimal.
From Cal Sensors menu for point to point systems.
Informs the operator that the most aggressive value allowed for
secondary manual tuning has been reached. Secondary tuning
should only be performed after primary tuning is optimized.
Security Code
From the
Security
menu.
Use to enter the security code to secure or unsecure the Spyder.
When secured only Remote Setpoint Tension and Percent Taper can
be changed.
Security Secured
Or
Security Not Secured
One of the top level menu screens. This screen also displays the
present state of security. When secured only Remote Setpoint
Tension and Percent Taper can be changed.
Sensing Roll is too heavy.
A load cell calibration error message.
See Load Cell Calibration
Problems
in Section 10.4.
Setpoint Tension
In the
Operator Loop
.
This is a display only of the tension setpoint. The tension setpoint is
set by either the Tension Input (Term.16 to Term.17) or by the
Ethernet connection. The source of the setpoint tension is
determined by Setpoint Source in the Configure menu.
Setpoint Tension
In the
Operator Loop
without taper tension
This is a display only of the tension setpoint. The tension setpoint is
set by either the Tension Input (Term.16 to Term.17) or by the
Ethernet connection. The source of the setpoint tension is
determined by Setpoint Source in the Configure menu.
Setpoint Position
In the
Operator Loop
.
For dancer with Setpoint = Analog this is only a display of the current
setpoint input between Term.16 and Term.17.
For dancer with Setpoint = Ethernet the position setpoint may be
entered on this screen by pressing the ENTER key or using the LEFT
and RIGHT keys to increment and decrement the position.
Setpoint Source
In the
Configure
menu.
Selects the setpoint source for either Tension or Position. The choice
is either Analog or Ethernet. The Spyder defaults to Analog input as
the setpoint source.
Signal too low at Max Tension
From the
Cal Sensors
menu.
The Spyder will not calibrate if the loading of the load cells at
Maximum Tension is less than 1/8 of the load cell rating.
Start Time
From the
Parameters
menu.
Enter a value based upon the amount of time it takes your machine to
ramp up from stopped to steady state operation. If the tension spikes
during this time, try increasing this START TIME value.