11.0
ALPHABETICAL LIST OF SCREEN DEFINITIONS
www.maxcessintl.com
MAGPOWR Spyder-Plus
MI 850A320 1 M
Page 42 of 60
11.0
The descriptions of individual screen functions are provided to aid the understanding of the control operation.
Calibration and tuning procedures included in this manual must be used for proper operation. The information
contained in this section is not sufficient to allow proper set-up.
Applied Tension
From
Cal Sensors
menu
Enter a value corresponding to the amount of known weight to be
used to calibrate the load cell(s). See also Section 6.3
Apply Minimum
Dancer Voltage
Or
Apply Maximum
Dancer Voltage
From the
Cal Dancer
menu.
Calibration of the dancer position signal. The voltage must be
between 0 VDC and 10 VDC. Minimum must be less than Maximum
as defined in Figure 12
Apply Min Set Position volts
Or
Apply Max Set Position volts
From the
Cal Dancer
menu.
Calibration of the Position Setpoint analog input. The voltage must be
between 0 VDC and 10 VDC. Minimum must be less than Maximum.
Apply Min Set Tension voltage
Or
Apply Max Set Tension voltage
Or
Apply Min Set Manual voltage
Or
Apply Min Set Manual voltage
From
Recal Inputs
menu.
Calibration of the Tension Setpoint and Manual Level analog inputs.
Either input must be between 0 VDC and 10 VDC. Min must be less
than Max.
Apply the Min or Max voltage to the appropriate input and press
Apply tension and press
From
Cal Sensors
menu.
Load cell calibration happens in two steps. In this second step the
weight used to calibrate the load cells should be applied at this time.
The weight should be applied near the center of the sensing roll using
a rope or narrow web.
Bar Graph Rate
From
Configure
menu.
Sets the update rate for the bar graphs on both the Tension/Position
screens and the Output Level screen.
Cal Dancer
One of the top level menu screens. Used to calibrate the dancer
inputs.
Cal Diameter
One of the top level menu screens. Used to calibrate diameter for
Open Loop Tension systems.
Cal Sensors
One of the top level menu screens. Used to calibrate the load cells.
Cal Setpoint
Input
Tension
Or
Cal Setpoint
Input
Manual
From the
Recal Inputs
menu.
Used to select whether the Tension input or the Manual input will be
calibrated. Use
or
to select the input to calibrate.
Calibrate Taper (Yes/No)
From
Taper Setup
menu.
When
is pressed on the
Present Dia
screen, the operator is asked
if taper should be calibrated. If “
Yes
” is selected the present diameter
is entered next.