INSTALLATION
www.maxcessintl.com
MAGPOWR DTR-65
MI 850A349 1 D
Electrical
installation
WARNING – Death or injury from shock may result from
wiring live power to the DTR-65.
Be sure the power is turned off and locked out before wiring
the DTR-65.
All wiring must comply with the essential requirements of
the appropriate standard(s) and is the responsibility of the
installer.
For fixed/permanent installation of the DTR-65, a suitable
switch or circuit-breaker must be installed as a
disconnecting device and this switch/circuit-breaker needs
to be labelled appropriately.
Wiring to the digital load cell amplifier must be insulated
copper wire with a temperature rating of at least 80
⁰
C. The
wire size must be at least 0.34 mm
2
(22 AWG). Use twisted
pair cable for the power. Use shielded cable for the load cell
and analog output wiring.
The DTR-65 can be powered by either 100-240 VAC 50-60
Hz or by 24 VDC. Only connect to one power source.