TECHNICAL DATA
9 - 5
DSE-17
www.maxcess.eu
MI 1064 1 C
TechnDaten.fm
Note:
The configuration of the sensor cannot be changed by the user.
Air supply (optional)
DSE-17-160
DSE-17-300
DSE-17-420
* These figures are approximate values. They can be adjusted to
the relevant application if necessary.
Filtration rating
5µm or better
Residual oil content
0.01mg/m³ or better
Standards
The DSE-17 sensor has been designed and constructed
according to the standards and regulations of the European
Union. A declaration of conformity is available on file.
Operating pressure
*
Air consumption
*
3bar
7.42m
3
/h
Up to 6 bar pulsing
3.7l/s
Operating pressure
*
Air consumption
*
1bar
3,76m
3
/h
2bar
7,78m
3
/h
Operating pressure
*
Air consumption
*
1bar
5,26m
3
/h
2bar
10,89m
3
/h