![MAXA HI-T Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/maxa/hi-t/hi-t_users-and-installers-manual_1743121027.webp)
Hi
‐
T
Centralized
controller
26
With
"
Manual
"
and
"
Manual
eco
"
the
set
‐
point
temperature
set
in
the
menu
"
Set
water
"
and
"
Set
water
eco
"
is
activated;
they
respectively
correspond
to
the
temperature
of
"normal"
operation
(1st
set
‐
point)
and
to
the
working
temperature
during
the
energy
‐
saving
operation
(set
‐
point
economy).
By
accessing
"
Set
Status
"
and
press
on
"
Chiller
"
you
can
only
manage
the
chiller
interested
in:
With
"
Manual
"
and
"
Manual
eco
",
the
set
‐
point
temperature
set
in
the
menu
"
Set
water
"
and
"
Set
water
eco
"
is
activated;
they
correspond
respectively
to
the
temperature
of
the
outlet
water
during
normal
operation
and
during
the
energy
‐
saving
operation
(Ex:
in
summer
mode
"
Set
water
"
might
be
7
°
C,
while
"
Set
water
eco
"
could
be
10
°
C).
By
accessing
"
Set
Status
"
and
press
on
"
ZoneN
"
you
can
manage
each
area
separately
(e.g.
the
activation
of
the
zone
1
is
not
a
sufficient
condition
for
the
chiller
to
power
on,
if
it
is
off):
With
"
Manual
"
and
"
Manual
eco
"
the
set
‐
point
temperature
set
in
the
menu
"
Set
water
"
and
"
Set
water
eco
"
is
activated;
they
respectively
correspond
to
the
temperature
of
"normal"
operation
(1st
set
‐
point)
and
to
the
working
temperature
during
the
energy
‐
saving
operation
(set
‐
point
economy).
Once
you
have
set
the
status,
in
the
"
Set
Status
"
the
following
icons
may
appear
in
the
coincidence
of
the
unit/zone
set:
OFF
MANUAL
ECONOMY
MANUAL
PROGRAMMED
Another
way
to
set
only
certain
areas/units
in
a
given
status
can
be
as
follows:
1.
set
"
System
"
in
the
manual,
manual
eco
or
programmed
mode;
2.
put
off
units/areas
that
you
do
not
want
to
activate.
Note:
Once
the
status
is
set,
you
must
wait
a
minute
to
ensure
that
communication
with
the
on
‐
board
control
of
the
units
in
the
network
is
going
and
the
units
themselves
are
activated
in
the
set
status.
4.6.2
ON/OFF
SANITARY
MODE
If
enabled
the
sanitary
mode
(from
Home
‐
>
Configuration
‐
>
Service
Menu
‐
>
Parameters
‐
>
Chiller
‐
>
Chiller
name
‐
>
H10:
sanitary
presence
=
1
),
in
"
Status
setup
"
also
appears
the
word
"
Sanitary
mode
".
From
here
you
can
decide
which
chiller
enable
to
produce
the
domestic
hot
water:
WINTER
SYSTEM
SUMMER
OFF
PROGRAMMED
MANUAL
MANUAL
ECO
OFF
PROGRAMMED
MANUAL
MANUAL
ECO
CHILLER
OFF
PROGRAMMED
MANUAL
MANUAL
ECO
ZONEn
OFF
PROGRAMMED
MANUAL
MANUAL
ECO