background image

21

8. HOW TO INSTALL OPTION-

AL 1260E TANK

With  AKHL1260E, you can add the optional 
AKTH13 air tank for 1260EX. If more air is re-
quired, use the following steps to install the op-
tional air tank.

Installation

1. (Fig.G,K) Turn off the power switch of the 

compressor and unplug the power cord 
from the electrical outlet. 

2. (Fig.D) Open the drain cock and drain 

compressed air from the tank. 

3. (Fig.M) Remove the four screws from the 

rubber feet of the compressor. 

4. (Fig.N,O) Remove the stop plug from the 

compressor clockwise and mount by turn-
ing the air chuck 44K that comes with the 
AKTH13 counterclockwise. 

5. (Fig.P) Mount the rubber feet of the compres-

sor on the holders of the AKTH13.

6. (Fig.Q) Fasten the four screws securely 

with a screwdriver.

7. (Fig.R) Connect the connector of the flexi-

ble pipe to the air chuck 44K. When con-
necting, please press the air plug strongly 
because the pressing is in two stages.

8. (Fig.L,C) Make sure that the four screws 

and the air chuck 44K are not loose, plug 
the compressor’s power cord in the elec-
tric outlet and turn the compressor’s 
power switch on.

9. Before operating the machine, be sure to 

carry out the "Inspection and checkup 
prior to operation" described on page 17.

Removal

1. (Fig.G,K) Turn off the power switch of the 

compressor and unplug the power cord 
from the electrical outlet. 

2. (Fig.D) Open the drain cock of the com-

pressor and optional air tank and drain 
compressed air from the tank. 

3. (Fig.S) Disconnect the connector of the 

flexible pipe from the air chuck 44K. Turn 
the sleeve of the air chuck 44K counter-
clockwise , and push the sleeve to remove 
the air plug.

4. (Fig.T) Remove the four screws of the rub-

ber feet that fasten the optional air tank to 
the compressor, and remove the air tank 
by lifting up the compressor. 

5. (Fig.U) Fasten the four screws with a 

screwdriver.

6. (Fig.L,C) Plug the compressor’s power 

cord in the electric outlet and turn the 
compressor’s power switch on. 

7. Before operating the machine, be sure to 

carry out the "Inspection and checkup 
prior to operation" described on page 17.

9. AUTOMATIC ADJUSTMENT 

OF OPERATING POWER (IN-
VERTER CONTROL)

Microcomputer-based inverter control is enabled 
on this machine in order to ensure the maximum 
utilization of the discharging performance. Adjust-
ment of the operating power is automatically con-
tinued until the pressure in the machine tank 
reaches the maximum level. Operating sounds 
may change when the operating power is 
switched, but you do not have to worry about them. 
Changes in the sounds are not due to a failure.

The pressure level at which the output change-
over is activated varies depending on the ca-
pacity of the main power supply, type of 
extension cord used and parallel use of other 
electric equipment. If the voltage is excessively 
low, extra time will be required for the filling.

If the fill time is longer than usual or when the 
pressure does not increase, change the cur-
rent connection to the power supply (reconnect 
to the main power supply) or stop the joint use 
of the power supply with a power tool.

When capacity of the main power is excessively 
low, or when it is jointly used with another power 
tool, a radical voltage drop results, may result in 
startup failure.

The circuit breaker of the power supply may be 
activated if the total current consumption re-
sulting from the parallel use with another pow-
er tool exceeds the current capacity of the 
circuit breaker.
If the circuit breaker trips, the power supply 
switch of the compressor moves to the OFF 
position.
Stop using other power tools on the same pow-
er source as the compressor. Then, after wait-
ing for 30 seconds or more, turn the switch ON.

Содержание AKHL1260E Powerlite

Страница 1: ...L ET LES CONSIGNES DE S CURIT AFIN DE GARANTIR UN FONCTIONNEMENT S R CONSERVER CE MANUEL EN LIEU S R AVEC L OUTIL AFIN DE POUVOIR LE CONSULTER ULTERIEUREMENT ANTES DE UTILIZAR ESTE COMPRESOR LEA DETEN...

Страница 2: ...e si no se evita puede resultar en muerte o lesiones graves PRECAUCI N Indica una situaci n potencialmente peligrosa que si no se evita puede resultar en una herida menor o moderada NOTA Destaca las i...

Страница 3: ...3 Fig A Abb A 2 1 5 7 8 9 b c 0 a d 4 3 6 h e f g Fig B Abb B j k l m i 9...

Страница 4: ...4 Fig C Abb C Fig D Abb D Fig E Abb E Fig F Abb F Fig G Abb G Fig H Abb H Fig I Abb I Fig J Abb J Fig K Abb K Fig L Abb L...

Страница 5: ...5 Fig M Abb M Fig N Abb N Fig O Abb O Fig P Abb P Fig Q Abb Q Fig R Abb R Fig S Abb S Fig T Abb T Fig U Abb U...

Страница 6: ...6...

Страница 7: ...WARNINGS AND ALL IN STRUCTIONS Failure to follow the warnings and instructions may result in death serious injury Save all warn ings and instructions for future reference RISK OF ELECTRIC SHOCK WARNIN...

Страница 8: ...y for EU countries Do not dispose of electric equipment together with household waste materi al In observance of European Directive 2012 19 EU on waste electrical and electronic equipment and its impl...

Страница 9: ...ower switch in the OFF position before connecting the compressor to its power source 7 STORE COMPRESSOR PROPERLY When not in use the compressor should be stored in dry place Keep out of reach of chil...

Страница 10: ...18 KEEP ALL SCREWS BOLTS AND COV ERS TIGHTLY IN PLACE Keep all screws bolts and plates tightly mounted Check their conditions periodically 19 KEEP HANDLES DRY CLEAN AND FREE FROM OIL AND GREASE Slippe...

Страница 11: ...RECT CURRENT POWER SUPPLY The compressor will break or be damaged from burning 34 THIS COMPRESSOR IS FOR INDOOR USE DO NOT INSTALL THE COMPRES SOR IN ANY PLACE EXPOSED TO RAIN OR SPLASHED WATER HIGH H...

Страница 12: ...sk of electric shock 3 SPECIFICATIONS Product No AKHL1260E EX CE AKHL1260E EX USA Dimensions L 583mm EX 583mm 23 EX 23 W 309mm EX 380mm 12 1 8 EX 15 H 337mm EX 479mm 13 1 4 EX 18 7 8 Weight 16 2kg EX...

Страница 13: ...pped with a cord having a grounding wire with an appropriate grounding plug The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordin...

Страница 14: ...fire due to burnout or ignition 7 AVOIDING A PLACE EXPOSED TO HIGH TEMPERATURE OR THE DIRECT SUN SHINE BE SURE TO USE THE MACHINE IN THE WELL VENTILATED SHADE Using it under high temperature or in the...

Страница 15: ...pressure on the pressure reduction valves REGULAR 8 3 bar 120psi maximum 7 High pressure air chuck for MAX tools It connects the MAX air hose for the tools 8 Regular pressure air chuck for regular pre...

Страница 16: ...the noises accompanying the operation or when tripping of the circuit breaker is anticipated during continuous operation Press the Quiet mode switch to turn on this mode A buzzer sounds with a beep a...

Страница 17: ...cannot move it anymore and make sure that the above operation moves the pressure gauge pointer Fig F at both locations As the pressure in the air tank increases due to the pressure characteristic of...

Страница 18: ...Due to Characteris tics of pressure reduction valve respectively 2 pressure reduction valves provided on this machine allow you to connect MAX and the general purpose nailer or pneumatic tool Pressure...

Страница 19: ...ems existing in the operating environment stop using the compressor and send it to your dealer or authorized service facility for checkups or repairs 6 ABNORMALITIES DURING OPERATION If you detect any...

Страница 20: ...xcessively high or low voltage 2 Long blinking Long beep sounds Pii Pii Pii Motor temperature went abnormally high Temperature in the control circuit has built up to an abnormally high level Do not us...

Страница 21: ...move the air tank by lifting up the compressor 5 Fig U Fasten the four screws with a screwdriver 6 Fig L C Plug the compressor s power cord in the electric outlet and turn the compressor s power switc...

Страница 22: ...its performance Please do not hesitate to let your dealer or authorized service facility in spect your machine more than once a year 4 Handle this machine carefully Droppingthemachine inadvertently b...

Страница 23: ...nos produits Las especificaciones y el dise o de los productos de este manual estar n sujetos a modificaci n sin previo aviso debido a nuestros continuos esfuerzos para mejorar la calidad de nuestros...

Отзывы: